Wenglor Y1TA100MHT88
  Wenglor Y1TA100MHT88

We are not the manufacturer, authorised distributor or authorised representative of the Wenglor brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

Y1TA100MHT88 Wenglor

Manufacturer

Wenglor

Country

Germany

Part number

Y1TA100MHT88

Description

Hochpräziser Abstandssensor

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications Y1TA100MHT88

If you are looking for Wenglor Y1TA100MHT88, connect FAMAGA, the world's prime supplier of streamlined equipment. Our company has advanced for more than ten years - these are cycles of experience, which are portrayed in the quality of outputs and special attention to each buyer. We respect everyone, who cooperated with us - therefore, our regular buyers bring in the most convenient purchase conditions and discounts on the industrial equipment market. At this time, there are more than 4000 such consumers, and we constantly make new agreements. More than 750 agreements are achieved per day, because FAMAGA works all over the planet . A well-elaborated logistics system and a partnership network allow us to send our products anywhere in the world as soon as possible without damaging product quality.

A particular source of repute for FAMAGA is its team members, each of whom contributes to common cause. We request into our team only experts, who already have experience in the sphere of manufacturing equipment.

All goods from FAMAGA are ensured - we are responsible for the outcome of our work. Now, more than 10 million units of products have been delivered, and this number is amounting every day. We are proud that purchasers choose FAMAGA again and again, and we are glad to make more exceptional and technologically advanced industrial equipment so as keep on top of it.

To get some advice or order, phone us or send a message to the online chat on our official website. You can also send a list of the necessary equipment to the email of firm - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.

Features Y1TA100MHT88

  • Analog output (0...10 V/4...20 mA)
  • Emitted light disengageable
  • Graphical display for easy operation
  • Temperature drift eliminable
These sensors have scratch-resistant optics and the emitted light can be switched off. They use the transit time measurement principle to measure the distance between the sensor and the object. For this reason, the object's color, shape and surface characteristics have practically no influence on measurement results. Even dark objects can be reliably recognized.
Working Range 0,1...10,1 m
Measuring Range 10 m
Resolution 1...12 mm
Linearity (Working Range 0,1...5 m) 0,05 %
Linearity (Working Range 5...10,1 m) 0,2 %
Switching Hysteresis 3...20 mm
Light Source Laser (red)
Wavelength 660 nm
Service Life (T = +25 °C) 100000 h
Laser Class (EN 60825-1) 2
Max. Ambient Light 10000 Lux
Beam Divergence < 2 mrad
Light Spot Diameter see Table 1
Reflector required no
Electrical Data
Supply Voltage 18...30 V DC
Current Consumption (Ub = 24 V) < 100 mA
Switching Frequency 50 Hz
Measuring Rate 1...100 /s
On-/Off-Delay 0...10000 ms
Temperature Drift (-10 °C < Tu < 50 °C) < 0,2 mm/K
Temperature Drift (Tu 50 °C) < 0,4 mm/K
Temperature Range -25...60 °C
Number of Switching Outputs 1
Switching Output Voltage Drop < 2,5 V
Switching Output/Switching Current 200 mA
Analog Output 0...10 V/4...20 mA
Short Circuit Protection yes
Reverse Polarity and Overload Protection yes
Interface RS-232
Protection Class III
FDA Accession Number 0710891-002
Mechanical Data
Setting Method Menu (OLED)
Housing Material Plastic
Degree of Protection IP68
Connection M12 ? 1, 8-pin
Safety-relevant Data
MTTFd (EN ISO 13849-1) 345,73 a
Output
Error Output yes
Configurable as PNP/NPN/Push-Pull yes
Analog Output yes
RS-232 Interface yes
Display brightness may decrease with age. This does not result in any impairment of the sensor function.