We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Keyence
Country
Japan
Name
FD-XA1
Type
Process Sensor
Description
90282000000 JAPANAnklemmbarer DurchflusssensorHaupteinheit, DIN-Schienenausführung
Stock availability:
On request
If you are questing Keyence FD-XA1 , communicate with FAMAGA, the world's central provider of machine made equipment. Our company has functioned for more than ten years - these are cycles of experience, which are illustrated in the quality of goods and personalseparate attention to each consumer. We esteem everyone, who joined with us - hence, our regular customers procure the most desirable purchase forms and discounts on the machine made streamlined equipment market. At this time, there are more than 4000 such clients, and we constantly sign new agreements. More than 750 agreements are achieved per day, because FAMAGA operates all over the globe Germany, United Kingdom, Cambodia, Denmark, Argentina, Guinea, Belarus, Laos, Burma, South Sudan, Central African Republic, Moldova, Algeria, Namibia, Brazil, Kuwait, Tonga, Equatorial Guinea, Rwanda, Uzbekistan, Hungary, Albania, Tajikistan, Chile, Libya, Russia, Norway, Kazakhstan, Armenia, Georgia, Sudan, Madagascar, Mali, Belize, Mongolia, Finland, Antigua and Barbuda, Bolivia, Uruguay, New Zealand, North Korea, Egypt. A well-built logistics system and a partnership network guide us to dispatch our goods anywhere in the globe with no delay without compromising product quality.
A particular source of pride for FAMAGA is its team members, each of whom contributes to our work. We propose into our team only specialists, who already have experience in the range of industrial equipment.
All goods from FAMAGA are assured - we are responsible for the aftereffect of our work. At this moment, more than 10 million units of products have been shipped, and this bulk is ascending every day. We are glad that consumers choose FAMAGA again and again, and we are happy to make more advanced and technologically modern industrial equipment so as to stay on the top.
To consult or make a request, call us by phone or write a message to the online chat on our official website. You can also forward a list of the desirable equipment to the email of corporation - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
Model | FD-XA1 | |
Type | DIN rail type, main unit | |
Display method | Output indicator, 4-digit 7 segment display, OLED, Stability level display | |
Display refresh frequency | Instantaneous flow: approx. 5 times/second, Discharge amount/Accumulated flow approx. 30 times/second | |
Response time | 50 ms/100 ms/500 ms/1 s/2.5 s/5 s/10 s/30 s/60 s (selectable, default: 500 ms) | |
Integration data storage interval | Written to the memory every 10 seconds | |
Memory back up | EEPROM (data storage period: more than 10 years, number of data rewritable times: 1 million times or more)*1 | |
Detection mode | ch.1 | Instantaneous flow rate mode/Area mode/Pulse output (+) mode/Integrated flow mode/Shot mode (selectable) |
ch.2 | Instantaneous flow rate mode/Area mode/Pulse output (-) mode/Shot mode/Error output mode/Bubble alert mode/Error + bubble alert mode (selectable) | |
Input/output | Output | NPN/PNP setting switch Open collector output: 30 V or lower, main unit: 50 mA or lower/ch.*2/expansion unit: 20 mA or lower/ch., residual voltage: 2 V or lower |
Analogue output | 4-20 mA/0-20 mA (selectable) load resistance: 500 ohms or lower | |
External input | Flow rate zero input/shot sampling input/integrated flow reset input/zero shift input (selectable) Short circuit current: NPN 1 mA or lower/PNP 2 mA or lower, input time: 20 ms or longer | |
Network support | IO-Link *3 | |
Protection circuit | Power supply reverse connection protection, power surge protection, output short circuit protection, output surge protection | |
Addition of expansion units | Up to 7*4 per main unit | |
Power supply | Power voltage | 20 to 30 VDC including 10 % ripple (P-P) , Class 2 |
Current consumption | 195 mA or lower (including the sensor head, excluding the load current) | |
Environmental resistance | Operating ambient temperature | -10 to +50 °C (No freezing) |
Operating ambient humidity | 35 % to 85 %RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, double amplitude 1.5 mm, 2 hours each for X,Y,Z direction | |
Shock resistance | 100 m/s2 (approx. 10 G) 16 ms pulse, 1000 times each for X,Y,Z direction | |
Material | Main body case/front sheet: PC, Key top: POM, Cable: PVC | |
Weight | Approx. 210 g | |
*1 Internal data for full time recording can be read by USB (Ver.2.0) communication. *2 20 mA or lower/ch when adding expansion units. *3 IO-Link: Specification v1.1/COM2 (38.4 kbps) is supported. If the end of the cable needs to be an M12 connector when supporting IO-Link communication, connect an M12 conversion connector (OP-88296) to the cable. *4 Consult the manual for the number of serially-connectable devices to the N-bus. |