Process Sensor FD-XA1 Keyence
Process Sensor FD-XA1 Keyence

We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

FD-XA1 Keyence Process Sensor

Manufacturer

Keyence

Country

Japan

Name

FD-XA1

Type

Process Sensor

Description

90282000000 JAPANAnklemmbarer DurchflusssensorHaupteinheit, DIN-Schienenausführung

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications FD-XA1

If you are questing Keyence FD-XA1 , communicate with FAMAGA, the world's central provider of machine made equipment. Our company has functioned for more than ten years - these are cycles of experience, which are illustrated in the quality of goods and personalseparate attention to each consumer. We esteem everyone, who joined with us - hence, our regular customers procure the most desirable purchase forms and discounts on the machine made streamlined equipment market. At this time, there are more than 4000 such clients, and we constantly sign new agreements. More than 750 agreements are achieved per day, because FAMAGA operates all over the globe . A well-built logistics system and a partnership network guide us to dispatch our goods anywhere in the globe with no delay without compromising product quality.

A particular source of pride for FAMAGA is its team members, each of whom contributes to our work. We propose into our team only specialists, who already have experience in the range of industrial equipment.

All goods from FAMAGA are assured - we are responsible for the aftereffect of our work. At this moment, more than 10 million units of products have been shipped, and this bulk is ascending every day. We are glad that consumers choose FAMAGA again and again, and we are happy to make more advanced and technologically modern industrial equipment so as to stay on the top.

To consult or make a request, call us by phone or write a message to the online chat on our official website. You can also forward a list of the desirable equipment to the email of corporation - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.

Features FD-XA1

Controller DIN rail type, main unit
Model FD-XA1
Type DIN rail type, main unit
Display method Output indicator, 4-digit 7 segment display, OLED, Stability level display
Display refresh frequency Instantaneous flow: approx. 5 times/second, Discharge amount/Accumulated flow approx. 30 times/second
Response time 50 ms/100 ms/500 ms/1 s/2.5 s/5 s/10 s/30 s/60 s (selectable, default: 500 ms)
Integration data storage interval Written to the memory every 10 seconds
Memory back up EEPROM (data storage period: more than 10 years, number of data rewritable times: 1 million times or more)*1
Detection mode ch.1 Instantaneous flow rate mode/Area mode/Pulse output (+) mode/Integrated flow mode/Shot mode (selectable)
ch.2 Instantaneous flow rate mode/Area mode/Pulse output (-) mode/Shot mode/Error output mode/Bubble alert mode/Error + bubble alert mode (selectable)
Input/output Output NPN/PNP setting switch Open collector output: 30 V or lower, main unit: 50 mA or lower/ch.*2/expansion unit: 20 mA or lower/ch., residual voltage: 2 V or lower
Analogue output 4-20 mA/0-20 mA (selectable) load resistance: 500 ohms or lower
External input Flow rate zero input/shot sampling input/integrated flow reset input/zero shift input (selectable) Short circuit current: NPN 1 mA or lower/PNP 2 mA or lower, input time: 20 ms or longer
Network support IO-Link *3
Protection circuit Power supply reverse connection protection, power surge protection, output short circuit protection, output surge protection
Addition of expansion units Up to 7*4 per main unit
Power supply Power voltage 20 to 30 VDC including 10 % ripple (P-P) , Class 2
Current consumption 195 mA or lower (including the sensor head, excluding the load current)
Environmental resistance Operating ambient temperature -10 to +50 °C (No freezing)
Operating ambient humidity 35 % to 85 %RH (No condensation)
Vibration resistance 10 to 55 Hz, double amplitude 1.5 mm, 2 hours each for X,Y,Z direction
Shock resistance 100 m/s2 (approx. 10 G) 16 ms pulse, 1000 times each for X,Y,Z direction
Material Main body case/front sheet: PC, Key top: POM, Cable: PVC
Weight Approx. 210 g
*1 Internal data for full time recording can be read by USB (Ver.2.0) communication. *2 20 mA or lower/ch when adding expansion units. *3 IO-Link: Specification v1.1/COM2 (38.4 kbps) is supported. If the end of the cable needs to be an M12 connector when supporting IO-Link communication, connect an M12 conversion connector (OP-88296) to the cable. *4 Consult the manual for the number of serially-connectable devices to the N-bus.