Mounting bracket FS-N43N Keyence
Mounting bracket FS-N43N Keyence

We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

FS-N43N Keyence Mounting bracket

Manufacturer

Keyence

Country

Japan

Name

FS-N43N

Type

Mounting bracket

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications FS-N43N

If you are pursuing Keyence FS-N43N , get in touch with FAMAGA, the world's foremost company of mechanized equipment. Our company has operated for more than ten years - these are cycles of experience, which are illustrated in the quality of spare parts and special attention to each orderer. We respect everyone, who engaged with us - thus, our regular buyers pick up the most flexible purchase forms and discounts on the machine made streamlined equipment market. At this time, there are more than 3500 such buyers, and we constantly sign new agreements. More than 700 proceedings are resolved per day, because FAMAGA delivers all over the globe . A well-elaborated logistics network and a partnership network let us to send our units anywhere in the globe promptly without discrediting product quality.

A particular source of honor for FAMAGA is its staff members, each of whom contributes to our work. We invite into our team only experts, who already have experience in the range of factory-made equipment.

All outcomes from FAMAGA are assured - we are responsible for the cause of our work. Nowadays, more than 10 million units of products have been supplied, and this bulk is rising every day. We are pleased that purchasers choose FAMAGA again and again, and we are eager to make more exceptional and technologically modern industrial equipment so as stay in control.

To ask a question or book, contact us or write a message to the online chat on our official website. You can also dispatch a list of the desirable equipment to the email of corporation - we will contact you ourselves with a prepared commercial proposal from FAMAGA.

Features FS-N43N

Fibre Amplifier, Cable Type, Main Unit, NPN
Model FS-N43N
Type Cable
Output type NPN
Main unit/expansion unit Main unit
Number of control outputs 2
Number of external inputs 1
Light source LED Transmitter side: Red, four-element LED (wavelength 660 nm)
Response time 23 µs (S-HSPD*1*2) / 50 µs (HSPD*3) / 250 µs (FINE) /500 µs (TURBO) / 1 ms (SUPER) / 4 ms (ULTRA) / 16 ms (MEGA) / 64 ms (TERA)
Control output Open-collector, 30 V or less 100 mA or less per output, 100 mA or less total for 2 outputs (when used as a solitary unit) / 20 mA or less (when used as an expansion unit) Residual voltage: 1.4 V or less (output current 10 mA or less) / 2 V or less (output current 10 to 100 mA)
External input Input time 2 ms (ON) / 20 ms (OFF) or longer*4
Unit expansion Up to 16 units (17 units connected in total including the main unit). However, each dual output type will be treated as two expansion units.
Protection circuit Protection against reverse power connection, output overcurrent, output surge, and reverse output connection
Mutual interference prevention S-HSPD/HSPD 0 units, FINE 4 units, TURBO/SUPER/ULTRA/MEGA/TERA 8 units (The mutual interference prevention values are twice those shown here when Double is set.)
Power supply Power voltage 10 to 30 VDC (including 10% ripple (P-P) or less) , class 2 or LPS*5
Current consumption During normal operation: 870 mW or less (34 mA or less at 24 V/62 mA or less at 12 V) ECO ON: 800 mW or less (31 mA or less at 24 V/56 mA or less at 12 V) ECO FULL: 710 mW or less (28 mA or less at 24 V/49 mA or less at 12 V)*6
Environmental resistance Ambient light Incandescent lamp: 20,000 lux or less, sunlight: 30,000 lux or less
Operating ambient temperature -20 °C to +55 °C (no freezing)*7
Vibration resistance 10 to 55 Hz, double amplitude 1.5 mm, 2 hours each for X, Y, and Z axes
Shock resistance 500 m/s2 , 3 times each for X, Y, and Z axes
Case material Main unit and cover: polycarbonate
Weight Approx. 83 g
*1 Restrictions when S-HSPD is selected: Output 2 of dual output types is fixed to OFF. *2 Restrictions when S-HSPD is selected Area detection, Area % Mode, DATUM, Rising edge, and Falling edge cannot be selected for Detection Mode. Output timer, Limit Detection, and Display Gain cannot be used. FULL cannot be selected for the ECO function. *3 Restrictions when HSPD is selected Display Gain cannot be used. *4 The input time becomes 25 ms (ON)/25 ms (OFF) when external calibration input is selected. *5 When expanding the system to 9 or more units, use a power supply voltage of 12 V or higher. *6 The load current is excluded. The power consumption including the load when the maximum number of units are connected is 38 W max. *7 When expanded by 1 to 2 units: -20 °C to +55 °C. When expanded by 3 to 10 units: -20 °C to +50 °C. When expanded by 11 to 16 units: -20 °C to +45 °C. When using 2 outputs, 1 unit is counted as 2 units. The prescribed values for the ambient temperature assume that the sensor amplifier has been mounted on a DIN rail installed on a metal surface. Exercise special care when installing the product in an airtight space.