Mounting bracket LV-11SBP Keyence
Mounting bracket LV-11SBP Keyence

We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

LV-11SBP Keyence Mounting bracket

Manufacturer

Keyence

Country

Japan

Name

LV-11SBP

Type

Mounting bracket

Description

Amplifier Unit, Main Unit, PNP

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications LV-11SBP

If you are pursuing Keyence LV-11SBP , contact FAMAGA, the world's major vendor of machine made equipment. Our company has existed for more than ten years - these are years of experience, which are symbolized in the quality of items and special attention to each buyer. We praise everyone, who liased with us - thus, our regular purchasers accept the most favorable purchase terms and discounts on the machine made streamlined equipment market. Now, there are more than 4000 such consumers, and we constantly make new agreements. More than 600 proceedings are resolved per day, because FAMAGA delivers all over the world . A well-built logistics series and a partnership network guide us to conduct our items anywhere in the globe with no delay without undermining product quality.

A particular source of dignity for FAMAGA is its staff members, each of whom contributes to our work. We request into our team only professionals, who already have experience in the range of machine made streamlined equipment.

All outputs from FAMAGA are ensured - we are responsible for the cause of our work. Nowadays, more than 10 million units of products have been provided, and this number is ascending every day. We are happy that users choose FAMAGA again and again, and we strive to make more exceptional and technologically developed industrial equipment so as stay in control.

To request or place an order, call us by phone or send a message to the online chat on our official website. You can also forward a list of the required equipment to the email of firm - we will contact you ourselves with a worked out commercial proposal from FAMAGA.

Features LV-11SBP

Amplifier Unit, Main Unit, PNP
Model LV-11SBP*1
Type Main unit
Output PNP
Control output PNP open-collector x 2 ch 30 VDC max. 100 mA max. per output
Response time ExceptLV-S31 ULTRA 4 ms
SUPER 2 ms
TURBO 500 µs
FINE 250 µs
HSP 80 µs
LV-S31standard mode 500 µs
LV-S31standard mode SPED2 2 ms
SPED3 8 ms
SPED4 32 ms
LV-S31High-speed mode 250 µs
Control input Light emission stop input, external calibration, set value bank selection input, or shift input
Number of interference prevention units ULTRA 4*2
SUPER
TURBO 2*2
FINE
HSP 0*2
Unit expansion Up to 16 expansion units can be installed (17 units including the main unit)*3
Rating Power voltage 12 to 24 VDC, Ripple (P-P) 10 % or less, Class 2*4
Power consumption Normal 1.7 W max. (70 mA max. for 24 V)
Ratings Eco-Half Eco-All 1.55 W max. (65 mA max. for 24 V)
Environmental resistance Ambient temperature -10 to +55 °C (No freezing)*5
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis
Material Main unit Main body, cover: Polycarbonate
Weight Approx. 80 g (including 2 m cable)
*1 LV-S62 and LV-S63 can ONLY be used with amplifiers ending with B or BP. *2 Numbers for the LV-S31 are four in standard mode and two in high-speed mode. *3 To connect several units they must be mounted on a METAL DIN rail. Ensure that the output current is 20 mA max. With several units connected, the allowable ambient temperature range varies as follows: 1 to 2 units connected: -10 to +55?C (14 to 131?F) 3 to 10 units connected: -10 to +50?C (14 to 122?F) 11 to 16 units connected: -10 to +45?C (14 to 113?F) *4 When more than 8 units connected, be sure to use supply voltage 24 VDC Ripple (P-P) 10 % max. *5 To connect several units they must be mounted on a METAL DIN rail. Ensure that the output current is 20 mA max. With several units connected, the allowable ambient temperature range varies as follows: 1 to 2 units connected: -10 to +55 °C, 3 to 10 units connected: -10 to +50 °C, 11 to 16 units connected: -10 to +45 °C