We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are questing Keyence LV-12S , make contact with FAMAGA, the world's key producer of factory-made equipment. Our company has lasted for more than ten years - these are cycles of experience, which are described in the quality of goods and individual attention to each consumer. We praise everyone, who worked with us - thus, our regular clients obtain the most desirable purchase forms and discounts on the machine made streamlined equipment market. At this time, there are more than 3500 such clients, and we constantly compose new agreements. More than 700 proceedings are resolved per day, because FAMAGA delivers all over the globe Germany, United Kingdom, Malta, Brazil, Comoros, Turkey, Congo, Sierra Leone, Moldova, Dominica, Mozambique, Kuwait, Bhutan, Lebanon, Georgia, Belarus, Iran, Japan, Antigua and Barbuda, Panama, Tanzania, Jamaica, Libya, Israel, North Korea, Estonia, Belize, Kenya, Eswatini, Thailand, Samoa, Mongolia, India, Andorra, Central African Republic, Iceland, Niger, Armenia, Czech Republic, Lithuania, Slovakia, Sudan, Guatemala. A advanced logistics bond and a partnership network let us to conduct our units anywhere in the globe promptly without undermining product quality.
A particular source of good name for FAMAGA is its workers, each of whom contributes to our work. We propose into our team only experts, who already have experience in the range of factory-made equipment.
All goods from FAMAGA are ensured - we are responsible for the cause of our work. Nowadays, more than 10 million units of products have been supplied, and this bulk is increasing every day. We are pleased that purchasers choose FAMAGA again and again, and we are pleased to make more exceptional and technologically modern industrial equipment so as stay in control.
To inquire or book, contact us or write a message to the online chat on our official website. You can also dispatch a list of the desirable equipment to the email of corporation - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
Model | LV-12S | ||
Type | Expansion unit (1 line) | ||
Main unit/Expansion unit | |||
Applicable model | LV-S41/S41L/S71/S72 | ||
Control output | NPN open-collector ? 2 channels, 40 VDC maximum, 100 mA or less per output | ||
Response time | ExceptLV-S31 | ULTRA | 4 ms |
SUPER | 2 ms | ||
TURBO | 500 µs | ||
FINE | 250 µs | ||
HSP | 80 µs | ||
LV-S31standard mode | 500 µs | ||
LV-S31standard mode | SPED2 | 2 ms | |
SPED3 | 8 ms | ||
SPED4 | 32 ms | ||
LV-S31High-speed mode | 250 µs | ||
Control input | Light emission stop input, external calibration, set value bank selection input, or received light intensity shift input | ||
Number of interference prevention units | ULTRA | 4 | |
SUPER | |||
TURBO | 2 | ||
FINE | |||
HSP | 0 | ||
Unit expansion | Up to 16 units (17 units total including the main unit)*1 | ||
Rating | Power voltage | 12 to 24 VDC, Ripple (P-P) 10 % or less, Class 2*2 | |
Power consumption | Normal | 1.5 W or less (62.5 mA or less at 24 V) | |
Ratings | Eco-Half Eco-All | 1.35 W or less (57.3 mA or less at 24 V) | |
Environmental resistance | Ambient temperature | -10 to +55 °C (No freezing)*3 | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis | ||
Material | Main unit | Main body, cover: Polycarbonate | |
Weight | Approx. 80 g (including 2 m cable) | ||
*1 When extended, the ambient usage temperature varies according to the following conditions. Be sure to mount units on a DIN rail (attached to a metal plate) and ensure that the output current is *2 When more than 8 units connected, be sure to use supply voltage 24 VDC Ripple (P-P) 10 % max. *3 To connect several units they must be mounted on a METAL DIN rail. Ensure that the output current is 20 mA max. With several units connected, the allowable ambient temperature range varies as follows: 1 to 2 units connected: -10 to +55 °C, 3 to 10 units connected: -10 to +50 °C, 11 to 16 units connected: -10 to +45 °C |