We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Keyence
Country
Japan
Name
GL-R12L
Type
Mounting bracket
Description
Main Unit, Body-protection Type, 12 Optical Axes
Stock availability:
On request
If you are inspecting Keyence GL-R12L , make contact with FAMAGA, the world's foremost company of mechanized equipment. Our company has operated for more than ten years - these are cycles of experience, which are described in the quality of goods and particular attention to each orderer. We praise everyone, who engaged with us - thus, our regular purchasers pick up the most desirable purchase forms and discounts on the machine made streamlined equipment market. At this time, there are more than 3500 such purchasers, and we constantly arrange new agreements. More than 700 proceedings are resolved per day, because FAMAGA delivers all over the globe Germany, United Kingdom, Peru, Malawi, Andorra, United Arab Emirates, France, Angola, Guinea, Cape Verde, Madagascar, Tajikistan, Morocco, Nicaragua, Cameroon, Jordan, Sierra Leone, Turkmenistan, Cyprus, Laos, Kyrgyzstan, Mauritania, Kiribati, Sudan, North Korea, Croatia, Australia, Liechtenstein, Iran, South Sudan, Montenegro, Swaziland, Malta, Yemen, Hungary, Brazil, Ireland, Lithuania, Denmark, Ghana, Costa Rica, Thailand, Eswatini, Bosnia and Herzegovina, Norway, Paraguay, Estonia. A well-shaped logistics network and a partnership network let us to ship our units anywhere in the globe promptly without damaging product quality.
A particular source of repute for FAMAGA is its personnel, each of whom contributes to our work. We call into our team only experts, who already have experience in the range of factory-made equipment.
All outcomes from FAMAGA are affirmed - we are responsible for the cause of our work. Nowadays, more than 10 million units of products have been supplied, and this bulk is amounting every day. We are pleased that purchasers choose FAMAGA again and again, and we are glad to make more exceptional and technologically modern industrial equipment so as stay in control.
To request or book, contact us or write a message to the online chat on our official website. You can also dispatch a list of the desirable equipment to the email of corporation - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
Model | GL-R12L | ||
Detection capability | o45 mm | ||
Beam axis spacing/Lens diameter | 40 mm / o5 | ||
Detecting distance | 0.2 to 15 m*1 | ||
Effective aperture angle | Max. ±2.5° (When operating distance is 3 m or more) | ||
Light source | Infrared LED (870 nm) | ||
Response time (OSSD) (ms) | Wire synchronisation, One-line or Optical synchronisation system (Channel 0) | ON>OFF | 6.6 |
OFF>ON | 48.7*2 | ||
All blocked>ON | 63.1*3 | ||
Optical synchronisation system (Channel A or B) | ON>OFF | 7.4 | |
OFF>ON | 49.9*2 | ||
All blocked>ON | 66.3*3 | ||
Detection mode | Turns on when no interruptions are present in the detection zone | ||
Synchronisation between the transmitter and receiver | Optical synchronisation or Wire synchronisation (Determined by wiring) | ||
Light interference prevention function | Prevents mutual interference in up to two GL-R systems. Optical synchronization: prevented by Channel A and B with setting switch Wire synchronization: prevented automatically | ||
Control output (OSSD output) | Output | 2 transistor outputs. (PNP or NPN is determined by the cable type) | |
Max. load current | 500 mA*4 | ||
Residual voltage (during ON) | Max. 2.5 V (with a cable length of 5 m) | ||
OFF state voltage | Max. 2.0 V (with a cable length of 5 m) | ||
Leakage current | Max. 200 µA | ||
Max. capacitive load | 2.2 µF | ||
Load wiring resistance | Max. 2.5 ? | ||
Supplemental output (Non-safety-related output) | AUX | transistor outputs. (PNP or NPN is determined by the cable type) Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 5 m) | |
Error output | |||
Muting lamp output | Incandescent lamp (24 VDC, 1 to 5.5 W) LED lamp (load current: 10 to 230 mA) can be connected. | ||
External input | When using a PNP output cable | EDM input Wait input Reset input Muting input 1, 2 Override input | ON voltage: 10 to 30 V OFF voltage: Open or 0 to 3 V Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only) |
When using an NPN output cable | ON voltage: 0 to 3 V OFF voltage: Open or 10 V or more Up to the power voltage Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only) | ||
Rating | Power voltage | 24 VDC ±20%, ripple (P-P) 10% or less, Class 2 | |
Power supply | Current consumption (Max.) (mA) | Transmitter | 46 |
Receiver | 70 | ||
Protection circuit | Reverse current protection, short-circuit protection for each output, surge protection for each output | ||
Approved standards | EMC | EMS | IEC61496-1, EN61496-1, UL61496-1 |
EMI | EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA | ||
Safety | IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD) IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3) EN ISO13849-1:2015 (Category 4, PLe) UL508 UL1998 | ||
Environmental resistance | Enclosure rating | IP65/IP67 (IEC60529) | |
Overvoltage category | II | ||
Ambient light | Incandescent lamp: 3,000 lux or less, Sunlight: 20,000 lux or less | ||
Operating ambient temperature | -10 to +55 °C (No freezing) | ||
Storage temperature | -25 to +60 °C (No freezing) | ||
Operating relative humidity | 15 to 85 % RH (No condensation) | ||
Storage relative humidity | 15 to 95 % RH | ||
Vibration resistance | 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions | ||
Shock resistance | 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions | ||
Material | Main unit case | Aluminium | |
Upper case/lower case | Nylon (GF 30%) | ||
Front cover | Polycarbonate, SUS304 | ||
Weight | Transmitter | 660 g | |
Receiver | |||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 1.0 m. *2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms. *3 “All blocked” means the situation where the GL-R operates in optical synchronisation system and the transmitter and receiver is not synchronised (top and bottom beam axes are both blocked). In this situation, the response time is longer because the GL-R synchronises the transmitter and receiver fi rst and then determines the clear or blocked. *4 When the GL-R is used under surrounding air temperatures between 50 to 55°C, the Maximum load current should not exceed 350 mA. |