CES-A-C5E-01 Euchner 077750
 CES-A-C5E-01 Euchner 077750

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

CES-A-C5E-01 077750 Euchner

Manufacturer

Euchner

Country

Germany

Name

CES-A-C5E-01

Part number

077750

Description

Sicherheitsschloss mit Betätiger CES-A-C5E-01

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications CES-A-C5E-01 077750

If you are questing Euchner CES-A-C5E-01 077750, reach FAMAGA, the world's main vendor of machine made equipment. Our company has worked for more than ten years - these are cycles of experience, which are outlined in the quality of outcomes and individual attention to each purchaser. We esteem everyone, who joined with us - hence, our regular buyers procure the most beneficial purchase conditions and discounts on the factory-made equipment market. Nowadays, there are more than 4 thousand such clients, and we constantly sign new agreements. More than 600 agreements are achieved per day, because FAMAGA supplies all over the planet . A well-elaborated logistics connection and a partnership network assist us to send our goods anywhere in the planet quickly without discrediting product quality.

A particular source of honor for FAMAGA is its workers, each of whom contributes to common cause. We invite into our team only experts, who already have experience in the direction of manufacturing equipment.

All spare parts from FAMAGA are assured - we are responsible for the aftereffect of our work. Now, more than 10 million units of products have been delivered, and this amount is increasing every day. We are happy that clients choose FAMAGA again and again, and we are eager to make more progressive and technologically innovative industrial equipment so as to stay on the top.

To ask a question or make a request, phone us or write a message to the online chat on our site. You can also forward a list of the necessary equipment to the email of firm - we will contact you ourselves with a worked out commercial proposal from FAMAGA.

Features CES-A-C5E-01 077750

  • Safety switch with integrated evaluation electronics
  • Possible to switch pulsed signals
  • 2 safety outputs (semiconductor outputs)
  • Category 3/PL e according to EN ISO 13849-1
  • Unicode
Approach directionCan be adjusted in 90° steps Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Category according to EN ISO 13849-1Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 3/PL e according to EN ISO 13849-1
LED indicator
STATEStatus LED
OUT/ERRORSafety outputs status / diagnostics LED (combined)
Additional connection
OUTMonitoring output (semiconductor)
Typical operating distancesAttention:The operating distance may vary depending on the background material and installation situation. (Only in combination with actuator CES-A-BBA, CES-A-BCA) Typical operating distance For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm must be maintained so that the operating distance of the side lobes is not entered. (Only in combination with actuator CES-A-BPA) Typical operating distance For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the operating distance of the side lobes is not entered.
Dimensions According to EN 60947-5-2: (LxWxH) 131x40x40
Housing material Plastic, PBT
Weight
Net 0,4 kg
Ambient temperature
At UB = 24 V DC -20 ... 55 °C
Degree of protection IP67
Mounting distance
Between 2 switches or 2 actuators min.80 mm
Installation orientation Any
Tightening torque
Screws fastening bracket read head max.0,6 Nm
Fixing screws housing max.1 Nm
Ready delay max.3 s
Reaction time
After change in the actuation status max.180 ms
Switching frequency max.1 Hz
Dwell time min.0,5 s
Connection M12 plug connector, 8-pin, screen can be applied
Electrical connection ratings
Operating voltage DC 18 ... 24 ... 27 V DC Regulated, residual ripple < 5 %
Current consumption 80 mA
Fusing
(External) operating voltage 0,25 ... 8 A
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In acc. with EN 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Safety outputs LA / LB
Type of output Semiconductor outputs, p-switching, short circuit-proof, electrically decoupled
Output voltage
HIGH U(LB) U(+LB) - 1,5 ... U(+LB) V DC
LOW U(LA) / U(LB) 0 ... 1 V DC
HIGH U(LA) U(+LA) - 1,5 ... U(+LA) V DC
Output current
per safety output 1 ... 400 mA
Fusing
External, safety circuit U(+LA) / U(+LB) 0.4 A medium slow-blow
Utilization category according to EN 60947-5-2
DC-13 24V 400mA
Switching load
According to UL max. DC 24 V, class 2
Rated conditional short-circuit current max.100 A
Discrepancy time
(Between the operating points of both safety outputs) max.120 ms
Power supply output load
U(+LA) / U(+LB) 24 V DC 18 ... 27 V DC
Monitoring output OUT
Type of output Semiconductor output, p-switching, short circuit-proof
Output voltage 0,8 x UB ... UB V DC
Output current max.20 mA
STATE LED
LED indicator Status LED
LED OUT / ERROR
LED indicator Safety outputs status / diagnostics LED (combined)
Work area
Repeat accuracy R max.10 %
Other
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 3
Performance Level PL e
PFHD 4.29 x 10-8
Diagnostic Coverage (DC) 90 %
Mission time 20 y
In combination with Actuator CES-A-BBA, CES-A-BCAOperating distance
Distance s, actuator
Minimum distance for side approach direction min.4 mm
Switch-on distance
With center offset m=0 20 mm
Assured switch-off distance Sar max.40 mm
Assured operating distance Sao
With center offset m=0 min.18 mm
Switching hysteresis min.2 mm
In combination with Actuator CES-A-BPAOperating distance
Distance s, actuator
Minimum distance for side approach direction min.6 mm
Switch-on distance
With center offset m=0 22 mm
Assured switch-off distance Sar max.58 mm
Assured operating distance Sao
With center offset m=0 min.15 mm
Switching hysteresis min.1 mm
In combination with Actuator CES-A-BDA-20Operating distance
Distance s, actuator
Minimum distance for side approach direction min.5 mm
Switch-on distance
With center offset m=0 21 mm
Assured switch-off distance Sar max.41 mm
Assured operating distance Sao
With center offset m=0 min.19 mm
Switching hysteresis min.2 mm