We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are pursuing Euchner CES-AR-CR2-CH-SA-112928 112928, get in touch with FAMAGA, the world's foremost company of mechanized equipment. Our company has advanced for more than ten years - these are years of experience, which are illustrated in the quality of merchandises and personalseparate attention to each orderer. We admire everyone, who liased with us - thus, our regular purchasers pick up the most convenient purchase conditions and discounts on the manufacturing equipment market. Today, there are more than 4000 such customers, and we constantly arrange new agreements. More than 750 purchases are terminated per day, because FAMAGA delivers all over the world Germany, United Kingdom, Gambia, Côte d\'Ivoire, Kiribati, Mongolia, Malta, New Zealand, Romania, Belgium, Ghana, Tunisia, Azerbaijan, Kenya, Liechtenstein, Greece, Iraq, Canada, Slovakia, Niger, Albania, Equatorial Guinea, Netherlands, Moldova, Botswana, Uganda, Comoros, Finland, Iceland, Austria, India, Djibouti, Israel, Qatar, Belize, Andorra, Bosnia and Herzegovina, Russia, Tanzania, Chile, Jordan, Czech Republic, Nigeria, Philippines, Central African Republic, Latvia. A well-developed logistics network and a partnership network assist us to dispatch our items anywhere in the world immediately without damaging product quality.
A special source of dignity for FAMAGA is its workers, each of whom contributes to our work. We accept into our team only specialists, who already have experience in the direction of machine made streamlined equipment.
All merchandises from FAMAGA are affirmed - we are responsible for the aftereffect of our work. At the moment, more than 10 million units of products have been provided, and this quantity is increasing every day. We are proud that clients choose FAMAGA again and again, and we are glad to make more progressive and technologically advanced industrial equipment so as stay in control.
To request or make a request, call us by phone or write to the online chat on our site. You can also dispatch a list of the required equipment to the email of organization - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
STATE | Status LED |
DIA | Diagnostics LED |
OUT | Monitoring output (semiconductor) |
RST | Reset input |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connection cable |
---|---|---|---|---|
1 | IB | Enable input for channel 2 | WH | |
2 | UB | Power supply, DC 24 V | BN | |
3 | OA | Safety output, channel 1 | GN | |
4 | OB | Safety output, channel 2 | YE | |
5 | OUT | Monitoring output | GY | |
6 | IA | Enable input for channel 1 | PK | |
7 | 0V | Ground, DC 0 V | BU | |
8 | RST | Reset input | RD |
Housing material | Plastic, PBT |
Weight | |
Net | 0,13 kg |
Ambient temperature | |
Cable static | -25 ... 65 °C |
Cable dynamic | 5 ... 65 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting method | Surface mounting on metal |
Mounting distance | |
Between 2 switches or 2 actuators | min.120 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | max.1 Nm |
Ready delay | 10 s |
Switching frequency | max.1 Hz |
Connection | Connection cable PVC, length 2m with plug connector M12 8-pin |
Bending radius | |
static | 5 x cable diameter |
Dynamic | 10 x cable diameter |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Regulated, residual ripple < 5 % |
Current consumption | max.50 mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In accordance with EN IEC 60947-5-3 and EN IEC 61326-3-1 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.400 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.260 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | max.50 mA |
Output voltage | 0,8 x UB ... UB V DC |
Safety outputs OA/OB | |
Test pulses | max.1 ms |
Test-pulse interval | min.140 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 200 mA |
Output voltage | |
HIGH U(OA) / U(OB) | UB-1,5V ... UB V DC |
LOW U(OA) / U(OB) | 0 ... 1 V DC |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated conditional short-circuit current | 100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 1.9 x 10-9 |
Mission time | 20 |
Switch-on distance | 15 mm |
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Assured operating distance Sao | min.10 mm |
Switching hysteresis | min.1 mm |
Switch-on distance | 19 mm |
Assured switch-off distance Sar | |
In x/z direction | max.40 mm |
In y direction | max.60 mm |
Assured operating distance Sao | min.14 mm |
Switching hysteresis | min.1 mm |