We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are questing Euchner CES-AR-CR2-CH-L20-109052 109052, get in touch with FAMAGA, the world's central distributor of machine made equipment. Our company has progressed for more than ten years - these are cycles of experience, which are symbolized in the quality of items and special attention to each client. We value everyone, who joined with us - thus, our regular clients accept the most attractive purchase forms and discounts on the factory-made equipment market. At present, there are more than 4 thousand such buyers, and we constantly compose new agreements. More than 600 contracts are concluded per day, because FAMAGA delivers all over the planet Germany, United Kingdom, The Bahamas, Bahrain, China, Peru, Croatia, Suriname, Malawi, Colombia, Madagascar, Jamaica, Bolivia, Fiji, Pakistan, Zimbabwe, Guinea, Mauritania, Egypt, Zambia, Costa Rica, Chad, Ireland, Namibia, Syria, Paraguay, Lithuania, Serbia, Afghanistan, Cape Verde, Kiribati, South Korea, Andorra, El Salvador, Cyprus, South Sudan, Belize, Vietnam, Belarus, The Gambia, Seychelles, Luxembourg, Malta, Dominica, Ghana. A well-shaped logistics connection and a partnership network let us to conduct our elements anywhere in the planet promptly without undermining product quality.
A special source of pride for FAMAGA is its staff members, each of whom contributes to common cause. We call into our team only specialists, who already have experience in the range of manufacturing equipment.
All outputs from FAMAGA are guaranteed - we are responsible for the cause of our work. Now, more than 10 million units of products have been delivered, and this amount is rising every day. We are happy that users choose FAMAGA again and again, and we strive to make more exceptional and technologically innovative industrial equipment so as to stay on the top.
To consult or book, phone us or write to the online chat on our site. You can also dispatch a list of the necessary equipment to the email of firm - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
STATE | Status LED |
DIA | Diagnostics LED |
OUT | Monitoring output (semiconductor) |
RST | Reset input |
Designation | Function | Conductor coloring of connection cable |
---|---|---|
IB | Enable input for channel 2 | WH |
UB | Power supply, DC 24 V | BN |
OA | Safety output, channel 1 | GN |
OB | Safety output, channel 2 | YE |
OUT | Monitoring output | GY |
IA | Enable input for channel 1 | PK |
0V | Ground, DC 0 V | BU |
RST | Reset input | RD |
Housing material | Plastic, PBT |
Weight | |
Net | 0,7 kg |
Ambient temperature | |
Cable static | -30 ... 65 °C |
Cable dynamic | -25 ... 65 °C |
Degree of protection | IP67, IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting method | Surface mounting on metal |
Mounting distance | |
Between 2 switches or 2 actuators | min.120 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | max.1 Nm |
Ready delay | 10 s |
Switching frequency | max.1 Hz |
Connection | connection cable PUR, length 20m |
Bending radius | |
Dynamic | 10 x cable diameter |
static | 5 x cable diameter |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Regulated, residual ripple < 5 % |
Current consumption | max.50 mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.400 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.260 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | max.50 mA |
Output voltage | 0,8 x UB ... UB V DC |
Safety outputs OA/OB | |
Test pulses | max.1 ms |
Test-pulse interval | min.140 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 200 mA |
Output voltage | |
HIGH U(OA) / U(OB) | UB-1,5V ... UB V DC |
LOW U(OA) / U(OB) | 0 ... 1 V DC |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated conditional short-circuit current | 100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 1.9 x 10-9 |
Mission time | 20 |
Switch-on distance | 19 mm |
Assured switch-off distance Sar | |
In x/z direction | max.40 mm |
In y direction | max.60 mm |
Assured operating distance Sao | min.14 mm |
Switching hysteresis | min.1 mm |
Switch-on distance | 15 mm |
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Assured operating distance Sao | min.10 mm |
Switching hysteresis | min.1 mm |