We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are pursuing Euchner CES-AP-CR2-CH-L05-105600 105600, connect FAMAGA, the world's main company of streamlined equipment. Our company has functioned for more than ten years - these are ages of experience, which are depicted in the quality of outputs and private attention to each user. We admire everyone, who engaged with us - therefore, our regular buyers pick up the most convenient purchase forms and discounts on the manufacturing equipment market. At this moment, there are more than 4500 such consumers, and we constantly make new agreements. More than 750 contracts are concluded per day, because FAMAGA operates all over the earth Germany, United Kingdom, Ecuador, Portugal, Mongolia, Mali, Eswatini, Sudan, The Bahamas, Grenada, Thailand, Andorra, Armenia, Jordan, Brazil, Guinea, Netherlands, Kyrgyzstan, Rwanda, Benin, Malawi, Nicaragua, Hungary, Egypt, Iraq, Indonesia, United States, Greece, Senegal, Laos, Serbia, Paraguay, Switzerland, Cameroon, Kenya, Antigua and Barbuda, Jamaica, Kiribati, Czech Republic, North Korea, Ghana, Lithuania, Panama, Algeria, Swaziland. A well-built logistics series and a partnership network cheer us to dispatch our goods anywhere in the earth with no delay without disreputing product quality.
A particular source of dignity for FAMAGA is its team members, each of whom contributes to common cause. We request into our team only professionals, who already have experience in the direction of machine made streamlined equipment.
All outputs from FAMAGA are assured - we are responsible for the aftereffect of our work. At the moment, more than 10 million units of products have been provided, and this quantity is ascending every day. We are glad that buyers choose FAMAGA again and again, and we are happy to make more progressive and technologically advanced industrial equipment so as not to lower the bar.
To ask a question or make a request, call us by phone or write a message to the online chat on our site. You can also send a list of the needful equipment to the email of organization - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
STATE | Status LED |
DIA | Diagnostics LED |
OUT | Monitoring output (semiconductor) |
Designation | Function | Conductor coloring of connection cable |
---|---|---|
UB | Power supply, DC 24 V | BN |
FO1A | Safety output, channel 1 | WH |
0V | Ground, DC 0 V | BU |
FO1B | Safety output, channel 2 | BK |
OUT | Monitoring output | GY |
- | n.c. | PK |
Housing material | Plastic, PBT |
Weight | |
Net | 0,22 kg |
Ambient temperature | |
Cable static | -40 ... 65 °C |
Cable dynamic | 0 ... 65 °C |
Degree of protection | IP67, IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting method | Surface mounting on metal |
Mounting distance | |
Between 2 switches or 2 actuators | min.400 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | max.1 Nm |
Ready delay | 0,5 s |
Switching frequency | max.1 Hz |
Connection | connection cable PVC, length 5m |
Bending radius | |
static | 5 x cable diameter |
Dynamic | 10 x cable diameter |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Regulated, residual ripple < 5 % |
Current consumption | max.30 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.300 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | max.260 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | max.50 mA |
Output voltage | 0,8 x UB ... UB V DC |
Safety outputs OA/OB | |
Test pulses | max.0,3 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 150 mA |
Output voltage | |
LOW U(OA) / U(OB) | 0 ... 1 V DC |
HIGH U(OA) / U(OB) | UB-1,5V ... UB V DC |
Rated conditional short-circuit current | 100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 1.8 x 10-9 |
Mission time | 20 |
Switch-on distance | 19 mm |
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Assured operating distance Sao | min.14 mm |
Switching hysteresis | min.1 mm |
Switch-on distance | 15 mm |
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Assured operating distance Sao | min.10 mm |
Switching hysteresis | min.1 mm |