We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CTP-L2-AR-M-HA-AZ-SAB-123361
Part number
123361
Stock availability:
On request
If you are seeking Euchner CTP-L2-AR-M-HA-AZ-SAB-123361 123361, call FAMAGA, the world's influential supplier of industrial equipment. Our company has operated for more than ten years - these are cycles of experience, which are symbolized in the quality of goods and personalseparate attention to each client. We respect everyone, who liased with us - so, our regular purchasers receive the most acceptable purchase conditions and discounts on the factory-made equipment market. Nowadays, there are more than 3500 such customers, and we constantly form new agreements. More than 700 agreements are achieved per day, because FAMAGA works all over the globe Germany, United Kingdom, Vietnam, Syria, Palestine, Zimbabwe, Madagascar, Jamaica, Namibia, Bhutan, Ecuador, Afghanistan, Guinea, Oman, Suriname, Burkina Faso, Honduras, Luxembourg, Lithuania, Philippines, Uzbekistan, Bosnia and Herzegovina, Albania, Moldova, Nicaragua, The Bahamas, Qatar, Monaco, Haiti, Tanzania, East Timor, Uganda, Senegal, Mozambique, Malaysia, Yemen, South Korea, Kyrgyzstan, Nepal, Denmark, Comoros, Macedonia, Costa Rica, Ghana, Egypt, Peru. A well-developed logistics system and a partnership network allow us to ship our goods anywhere in the globe with no delay without compromising product quality.
A special source of repute for FAMAGA is its personnel, each of whom contributes to our work. We accept into our team only specialists, who already have experience in the range of manufacturing equipment.
All merchandises from FAMAGA are affirmed - we are responsible for the aftereffect of our work. At this moment, more than 10 million units of products have been supplied, and this amount is amounting every day. We are pleased that buyers choose FAMAGA again and again, and we strive to make more exceptional and technologically innovative industrial equipment so as to stay on the top.
To request or make a request, get in touch with us or write to the online chat on our site. You can also direct a list of the desirable equipment to the email of organization - we will contact you ourselves with a made commercial proposal from FAMAGA.
CTP?L2 | Guard locking actuated by power-ON applied and spring released (open-circuit current principle). |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connecting cable |
---|---|---|---|---|
X 1.1 | FI1B | Enable input for channel 2 | WH | |
X 1.2 | UB | Operating voltage of AR electronics 24 V DC | BN | |
X 1.3 | FO1A | Safety output, channel 1 | GN | |
X 1.4 | FO1B | Safety output, channel 2 | YE | |
X 1.5 | OL | Guard locking monitoring output | GY | |
X 1.6 | FI1A | Enable input for channel 1 | PK | |
X 1.7 | 0 V UB | Operating voltage of AR electronics 0 V | BU | |
X 1.8 | RST | Reset input | RD | |
X 2.1 | IMM | Operating voltage of guard locking solenoid 0 V | BN | |
X 2.2 | OD | Door monitoring output | WH | |
X 2.3 | OI | Diagnostic output | BU | |
X 2.4 | IMP | Operating voltage of guard locking solenoid 24 V DC | BK | |
X 2.5 | - | n.c. | GY |
Housing material | |
Switch head cover | Die-cast zinc |
Safety switch housing | Fiber glass reinforced thermoplastic |
Weight | |
Net | 0,42 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... +55 °C |
Degree of protection | IP67 / IP69 / IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | 8 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5 and 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Open-circuit current principle |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Retention force | 20 N |
Extraction force | 20 N |
Actuating force | 10 N |
Overtravel | 5 mm |
Test-pulse interval | min.140 ms |
Test pulses | max.1,0 ms |
Operating voltage DC | |
UUB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IIMP | 400 mA |
IUB | 40 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (solenoid operating voltage IMP) | 0,5 ... 8 A |
External (operating voltage UB) | 0,25 ... 2 A |
Rated insulation voltage Ui | max.50 V |
Rated impulse withstand voltage Uimp | max.0,5 kV |
Power consumption | 6 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.260 ms |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs FO1A / FO1B | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output FO1A / FO1B | 1 ... 150 mA |
Output voltage | |
High U(FO1A) / U(FO1B) | UB-1,5 ... UB V DC |
Low U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Switch-on time | max.400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms In acc. with EN IEC 60947-5-3 |
Monitoring output OL | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OD | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OI | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Repeat accuracy R | 10 % |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Performance Level | PL e |
Category | 4 |
PFHD | 4.1 x 10 -9 |
Mission time | 20 y |