CTP-L1-AR-U-HA-AZ-SAB-122812 Euchner 122812
 CTP-L1-AR-U-HA-AZ-SAB-122812 Euchner 122812

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

CTP-L1-AR-U-HA-AZ-SAB-122812 122812 Euchner

Manufacturer

Euchner

Country

Germany

Name

CTP-L1-AR-U-HA-AZ-SAB-122812

Part number

122812

Description

Safety switch CTP-L1-AR-U-HA-AZ-SAB-122 812

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications CTP-L1-AR-U-HA-AZ-SAB-122812 122812

If you are inspecting Euchner CTP-L1-AR-U-HA-AZ-SAB-122812 122812, get in touch with FAMAGA, the world's dominant producer of machine made equipment. Our company has functioned for more than ten years - these are cycles of experience, which are illustrated in the quality of items and special attention to each purchaser. We respect everyone, who worked with us - thus, our regular clients obtain the most flexible purchase conditions and discounts on the factory-made equipment market. At this moment, there are more than 4 thousand such buyers, and we constantly form new agreements. More than 700 agreements are achieved per day, because FAMAGA delivers all over the planet . A well-elaborated logistics connection and a partnership network allow us to conduct our goods anywhere in the planet as soon as possible without compromising product quality.

A special source of good name for FAMAGA is its employees, each of whom contributes to common cause. We invite into our team only professionals, who already have experience in the range of manufacturing equipment.

All spare parts from FAMAGA are ensured - we are responsible for the outcome of our work. Nowadays, more than 10 million units of products have been supplied, and this amount is growing every day. We are happy that customers choose FAMAGA again and again, and we strive to make more exceptional and technologically innovative industrial equipment so as stay in control.

To inquire or place an order, contact us or write to the online chat on our site. You can also dispatch a list of the necessary equipment to the email of our company - we will contact you ourselves with a prepared commercial proposal from FAMAGA.

Features CTP-L1-AR-U-HA-AZ-SAB-122812 122812

  • Safety switch with guard locking and integrated evaluation electronics
  • Up to 20 switches in series
  • Short circuit monitoring
  • Two safety outputs (semiconductor outputs)
  • Up to category 4/PL e according to EN ISO 13849-1
  • With two plug connectors M12
  • Unicode
  • Door monitoring output
  • Approach directions A, B and C (delivery state)
Approach direction Horizontal Can be adjusted in 90° steps Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Guard locking type
CTP?L1Guard locking actuated by spring force applied and power-ON released (closed-circuit current principle)
Connector assignment
Plug connector (view of connection side) Pin Designation Function Conductor coloring of connecting cable
X 1.1 FI1B Enable input for channel 2 WH
X 1.2 UB Operating voltage of AR electronics 24 V DC BN
X 1.3 FO1A Safety output, channel 1 GN
X 1.4 FO1B Safety output, channel 2 YE
X 1.5 OL Guard locking monitoring output GY
X 1.6 FI1A Enable input for channel 1 PK
X 1.7 0 V UB Operating voltage of AR electronics 0 V BU
X 1.8 RST Reset input RD
X 2.1 IMM Operating voltage of guard locking solenoid 0 V BN
X 2.2 OD Door monitoring output WH
X 2.3 OI Diagnostic output BU
X 2.4 IMP Operating voltage of guard locking solenoid 24 V DC BK
X 2.5 - n.c. GY
Housing material
Switch head cover Die-cast zinc
Safety switch housing Fiber glass reinforced thermoplastic
Weight
Net 0,42 kg
Ambient temperature
At UB = 24V DC -20 ... +55 °C
Degree of protection IP67 / IP69 / IP69K
Resilience to vibration In acc. with EN IEC 60947-5-3
Mechanical life 1 x 106
Installation orientation Any
Ready delay 8 s
Switching frequency max.0,5 Hz
Connection 2 plug connectors M12, 5 and 8-pin
Approach speed 20 m/min
Guard locking principle Closed-circuit current principle
Locking force Fmax 3900 N
Locking force FZh 3000 N
Retention force 20 N
Extraction force 20 N
Actuating force 10 N
Overtravel 5 mm
Electrical connection ratings
Test-pulse interval min.140 ms
Test pulses max.1,0 ms
Operating voltage DC
UUB 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Current consumption
IUB 40 mA
IIMP 400 mA
Utilization category according to EN 60947-5-2
DC-13 24V 150mA
Solenoid operating voltage DC
UIMP 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Fusing
External (operating voltage UB) 0,25 ... 2 A
External (solenoid operating voltage IMP) 0,5 ... 8 A
Rated insulation voltage Ui max.50 V
Rated impulse withstand voltage Uimp max.0,5 kV
Power consumption 6 W
EMC protection requirements In acc. with EN IEC 60947-5-3
Solenoid duty cycle 100 %
Degree of contamination (external, according to EN 60947-1) 3
Safety class
EN IEC 61140 III
Risk time according to EN 60947-5-3
Delay per device 5 ms
Single device max.260 ms
Switching load
According to UL 24V DC, class 2
Monitoring output OD
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC
Monitoring output OI
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC
Safety outputs FO1A / FO1B
Type of output 2 semiconductor outputs, p-switching, short circuit-proof
Switching current
Per safety output FO1A / FO1B 1 ... 150 mA
Output voltage
High U(FO1A) / U(FO1B) UB-1,5 ... UB V DC
Low U(FO1A) / U(FO1B) 0 ... 1 V DC
Off-state current Ir max.0,25 mA
Switch-on time max.400 ms
Discrepancy time
Both safety outputs max.10 ms In acc. with EN IEC 60947-5-3
Monitoring output OL
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC
Work area
Repeat accuracy R 10 %
Other
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures see operating instructions
Reliability values according to EN ISO 13849-1
Performance Level PL e
Category 4
PFHD 4.1 x 10 -9
Mission time 20 y