We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CTP-L1-AR-U-HA-AZ-SAB-122812
Part number
122812
Description
Safety switch CTP-L1-AR-U-HA-AZ-SAB-122 812
Stock availability:
On request
If you are inspecting Euchner CTP-L1-AR-U-HA-AZ-SAB-122812 122812, get in touch with FAMAGA, the world's dominant producer of machine made equipment. Our company has functioned for more than ten years - these are cycles of experience, which are illustrated in the quality of items and special attention to each purchaser. We respect everyone, who worked with us - thus, our regular clients obtain the most flexible purchase conditions and discounts on the factory-made equipment market. At this moment, there are more than 4 thousand such buyers, and we constantly form new agreements. More than 700 agreements are achieved per day, because FAMAGA delivers all over the planet Germany, United Kingdom, Cape Verde, Tajikistan, Grenada, Italy, Nepal, Panama, Chile, Gambia, Cameroon, Swaziland, Liberia, Costa Rica, Mexico, Netherlands, Guinea, Pakistan, Brazil, United Arab Emirates, Canada, Burundi, Monaco, United States, Israel, The Gambia, El Salvador, Bolivia, Russia, Nicaragua, India, The Bahamas, Sierra Leone, Uruguay, Madagascar, Switzerland, Sweden, Afghanistan, Ghana, East Timor, Macedonia, Brunei, Mongolia, Georgia, Iran, Mozambique, Benin. A well-elaborated logistics connection and a partnership network allow us to conduct our goods anywhere in the planet as soon as possible without compromising product quality.
A special source of good name for FAMAGA is its employees, each of whom contributes to common cause. We invite into our team only professionals, who already have experience in the range of manufacturing equipment.
All spare parts from FAMAGA are ensured - we are responsible for the outcome of our work. Nowadays, more than 10 million units of products have been supplied, and this amount is growing every day. We are happy that customers choose FAMAGA again and again, and we strive to make more exceptional and technologically innovative industrial equipment so as stay in control.
To inquire or place an order, contact us or write to the online chat on our site. You can also dispatch a list of the necessary equipment to the email of our company - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
CTP?L1 | Guard locking actuated by spring force applied and power-ON released (closed-circuit current principle) |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connecting cable |
---|---|---|---|---|
X 1.1 | FI1B | Enable input for channel 2 | WH | |
X 1.2 | UB | Operating voltage of AR electronics 24 V DC | BN | |
X 1.3 | FO1A | Safety output, channel 1 | GN | |
X 1.4 | FO1B | Safety output, channel 2 | YE | |
X 1.5 | OL | Guard locking monitoring output | GY | |
X 1.6 | FI1A | Enable input for channel 1 | PK | |
X 1.7 | 0 V UB | Operating voltage of AR electronics 0 V | BU | |
X 1.8 | RST | Reset input | RD | |
X 2.1 | IMM | Operating voltage of guard locking solenoid 0 V | BN | |
X 2.2 | OD | Door monitoring output | WH | |
X 2.3 | OI | Diagnostic output | BU | |
X 2.4 | IMP | Operating voltage of guard locking solenoid 24 V DC | BK | |
X 2.5 | - | n.c. | GY |
Housing material | |
Switch head cover | Die-cast zinc |
Safety switch housing | Fiber glass reinforced thermoplastic |
Weight | |
Net | 0,42 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... +55 °C |
Degree of protection | IP67 / IP69 / IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | 8 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5 and 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Retention force | 20 N |
Extraction force | 20 N |
Actuating force | 10 N |
Overtravel | 5 mm |
Test-pulse interval | min.140 ms |
Test pulses | max.1,0 ms |
Operating voltage DC | |
UUB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 2 A |
External (solenoid operating voltage IMP) | 0,5 ... 8 A |
Rated insulation voltage Ui | max.50 V |
Rated impulse withstand voltage Uimp | max.0,5 kV |
Power consumption | 6 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.260 ms |
Switching load | |
According to UL | 24V DC, class 2 |
Monitoring output OD | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OI | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Safety outputs FO1A / FO1B | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output FO1A / FO1B | 1 ... 150 mA |
Output voltage | |
High U(FO1A) / U(FO1B) | UB-1,5 ... UB V DC |
Low U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Switch-on time | max.400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms In acc. with EN IEC 60947-5-3 |
Monitoring output OL | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Repeat accuracy R | 10 % |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Performance Level | PL e |
Category | 4 |
PFHD | 4.1 x 10 -9 |
Mission time | 20 y |