MGB-L2-ARA-AM3A1-M-R-121237 Euchner 121237
 MGB-L2-ARA-AM3A1-M-R-121237 Euchner 121237

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

MGB-L2-ARA-AM3A1-M-R-121237 121237 Euchner

Manufacturer

Euchner

Country

Germany

Name

MGB-L2-ARA-AM3A1-M-R-121237

Part number

121237

Description

Sicherheitssysteme MGB-L2-ARA-AM3A1-MR-121237

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications MGB-L2-ARA-AM3A1-M-R-121237 121237

If you are inspecting Euchner MGB-L2-ARA-AM3A1-M-R-121237 121237, reach FAMAGA, the world's top supplier of mechanized equipment. Our company has existed for more than ten years - these are ages of experience, which are portrayed in the quality of products and personalseparate attention to each orderer. We praise everyone, who engaged with us - hence, our regular buyers receive the most beneficial purchase forms and discounts on the factory-made equipment market. Now, there are more than 4500 such customers, and we constantly compose new agreements. More than 700 contracts are concluded per day, because FAMAGA supplies all over the earth . A well-developed logistics network and a partnership network let us to conduct our products anywhere in the earth promptly without undermining product quality.

A particular source of good name for FAMAGA is its employees, each of whom contributes to common cause. We accept into our team only specialists, who already have experience in the range of manufacturing equipment.

All merchandises from FAMAGA are assured - we are responsible for the cause of our work. Now, more than 10 million units of products have been supplied, and this amount is growing every day. We are glad that purchasers choose FAMAGA again and again, and we are pleased to make more exceptional and technologically innovative industrial equipment so as keep on top of it.

To ask a question or book, phone us or write a message to the online chat on our site. You can also forward a list of the needful equipment to the email of corporation - we will contact you ourselves with a worked out commercial proposal from FAMAGA.

Features MGB-L2-ARA-AM3A1-M-R-121237 121237

  • Guard locking with guard lock monitoring
  • Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
  • Emergency stop according to ISO 13850
  • 2 pushbuttons (illuminated)
  • With lens set, 6 pcs.
  • With cable entry
  • Unicode
Guard locking type
MGB-L2...The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle, electrically locked).
Door hingeA mechanical door stop is permanently integrated into the evaluation module of the MGB. A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Monitoring outputs
ODON when the door is closed
OTBolt tongue inserted in the evaluation module
OLGuard locking solenoid in locked position
OIDiagnostics, there is a fault
Emergency stop device
S12 positively driven NC contacts and 1 NO contact (e.g. monitoring contact), emergency stop with turn-to-reset, not illuminated
Pushbutton
S21 NO contact, illuminated
S31 NO contact, illuminated
Lens setThe color of the pushbutton can be selected using the lens set included (5 colors). Item no.: 120344 (see Accessories) Dimension drawing Cable entry MGB: The MGB-System in use MGB: MGB Impact test MGB: Mounting left door, with escape release Mounting left door, without escape release Mounting right door, without escape release MGB: Changing single wiring (AP) to series wiring (AR) MGB: Deactivating guard lock monitor MGB: Activating guard lock monitor MGB: Activating release monitoring MGB: Change color-lens push button Dimension drawingCable entry Technical dataApprovals Mechanical values and environment
Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
Weight
Net 0,75 kg
Ambient temperature
At UB = 24V DC -20 ... 55 °C
Degree of protection IP65
Mechanical life 1 x 106
In case of use as door stop, and 1 Joule impact energy 0,1 x 106
Installation orientation Door hinge DIN right
Switching frequency 0,25 Hz
Connection Cable entries M20x1.5
Guard locking principle Open-circuit current principle
Locking force FZh 2000 N
Electrical connection ratings
Utilization category according to EN 60947-5-2
DC-13 24V 200mA
Rated insulation voltage Ui 30 V
Rated impulse withstand voltage Uimp 1,5 kV
Degree of contamination (external, according to EN 60947-1) 3
Connection cross-section
(Rigid/flexible) with cable end sleeve according to DIN 46 228/1 0,25 ... 1,5 mm?
(Rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 0,25 ... 0,75 mm?
(Rigid/flexible) 0,13 ... 1,5 mm? (AWG 24 ... AWG 16)
Safety class III
Discrepancy time
Between FO1A and FO1B max.10 ms
Risk time according to EN 60947-5-3 max.350 ms
Transponder coding Unicode
Power supply UB
Operating voltage DC
UB 24 V DC -15% ... 10%
Current consumption
IUB max.80 mA
Power supply UA
Operating voltage DC
UA 24 V DC -15% ... 10%
Current consumption
IUA max.375 mA
Safety outputs FO1A, FO1B
Test pulses max.1 ms
Test-pulse interval min.100 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Output voltage
UFO1A /UFO1B HIGH UB-2V ... UB V DC
UFO1A /UFO1B LOW 0 ... 1 V DC
Output current
Per safety output FO1A / FO1B 1 ... 200 mA
Monitoring outputs OD, OT, OL, OI
Type of output Semiconductor outputs, p-switching, short circuit-proof
Output voltage UA-2V ... UA V DC
Output current max.50 mA
Controls and indicators
Switching voltage UA V
Switching current 1 ... 10 mA
Breaking capacity max.0,25 W
Power supply LED 24 V DC
Emergency stop
Switching voltage 5 ... 24 V
Switching current 1 ... 100 mA
Breaking capacity max.0,25 W
Power supply LED 24 V DC
Solenoid control input IMP1, IMP2, IMM
Test pulses max.5 ms
Test-pulse interval min.100 ms
Controls and indicators
Belegungsschema L1
Position 1
Ausfuhrung Emergency stop
Einlegeschild
Extras With auxiliary contact
Farbe
Schaltelement 2 pos. driven NC + 1NO
Position 2
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe
Schaltelement 1NO
Position 3
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe
Schaltelement 1NO
Other
Additional feature Incl. cover set ID. No. 120344
Product version number V3.0.3
Reliability values according to EN ISO 13849-1
Monitoring of guard locking and the safety guard position
Category 4
Performance Level PL e
PFHD 3.7 x 10-9
Emergency stop
B10D
Emergency stop 0,065 x 106
Mission time 20 y