We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
MGB-L1H-ARA-L-121107
Part number
121107
Description
Schutzgerät EUC.121107 MGB-L1H-ARA-L-121107
Stock availability:
On request
If you are inspecting Euchner MGB-L1H-ARA-L-121107 121107, communicate with FAMAGA, the world's primary distributor of industrialized equipment. Our company has progressed for more than ten years - these are years of experience, which are symbolized in the quality of items and personalseparate attention to each user. We cherish everyone, who conspired with us - so, our regular customers accept the most helpful purchase conditions and discounts on the factory-made equipment market. Today, there are more than 4 thousand such customers, and we constantly compose new agreements. More than 600 affairs are settled per day, because FAMAGA works all over the earth Germany, United Kingdom, Suriname, Cuba, Iceland, Kyrgyzstan, Albania, Angola, Indonesia, Netherlands, Austria, Japan, Singapore, Georgia, Ukraine, Eritrea, Philippines, Ecuador, Nepal, Romania, South Korea, Latvia, Poland, Zambia, Mozambique, Denmark, Malaysia, United States, Croatia, Malta, Pakistan, Belize, Benin, Jamaica, Zimbabwe, Panama, Mauritania, The Gambia, Comoros, Peru, Andorra, Costa Rica, Thailand. A advanced logistics series and a partnership network guide us to conduct our elements anywhere in the planet quickly without compromising product quality.
A special source of pride for FAMAGA is its workers, each of whom contributes to common cause. We accept into our team only professionals, who already have experience in the direction of manufacturing equipment.
All outputs from FAMAGA are guaranteed - we are responsible for the result of our work. At this moment, more than 10 million units of products have been delivered, and this amount is growing every day. We are happy that users choose FAMAGA again and again, and we are pleased to make more developed and technologically modern industrial equipment so as to stay on the top.
To consult or order, phone us or send a message to the online chat on our site. You can also forward a list of the necessary equipment to the email of firm - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
MGB-L1... | The locking arm is held in the locked position by spring force and is unlocked by solenoid force (closed-circuit current principle, mechanically locked). |
OT | Bolt tongue inserted in the evaluation module |
OL | Guard locking solenoid in locked position |
OI | Diagnostics, there is a fault |
S1 | 1 NO contact, illuminated |
S2 | 1 NO contact, illuminated |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 1,00 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP65 |
Installation orientation | Door hinge DIN left |
Product version number | V3.0.0 |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 0,75 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN left |
Switching frequency | 0,25 Hz |
Connection | Plug connector RC18 |
Guard locking principle | Closed-circuit current principle |
Locking force FZh | 2000 N |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.375 mA |
Safety outputs FO1A, FO1B | |
Test pulses | max.1 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
Controls and indicators | |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Solenoid control input IMP1, IMP2, IMM | |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
Additional feature | Incl. cover set ID. No. 120344 |
Product version number | V3.0.3 |
Slide-in label | 2 pcs. without marking |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Control of the guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 2.8 x 10-9 |
Mission time | 20 y |