We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
MGB-L1-ARA-AD3A1-S1-L-119759
Part number
119759
Stock availability:
On request
If you are looking for Euchner MGB-L1-ARA-AD3A1-S1-L-119759 119759, call FAMAGA, the world's principle provider of machine made equipment. Our company has lasted for more than ten years - these are ages of experience, which are symbolized in the quality of outcomes and private attention to each purchaser. We value everyone, who worked with us - so, our regular customers get the most attractive purchase terms and discounts on the factory-made equipment market. At present, there are more than 4 thousand such consumers, and we constantly compose new agreements. More than 600 contracts are concluded per day, because FAMAGA works all over the planet Germany, United Kingdom, Vietnam, The Gambia, Uruguay, Singapore, Slovenia, Syria, Mauritania, Tonga, Eritrea, Albania, Monaco, Panama, The Bahamas, Luxembourg, Bhutan, Burkina Faso, Senegal, Peru, Poland, Togo, Brazil, Qatar, Guyana, South Sudan, Bangladesh, El Salvador, Austria, Seychelles, Tajikistan, Mozambique, Kyrgyzstan, Costa Rica, Niger, Finland, Zimbabwe, South Korea, Pakistan, Argentina, Afghanistan, Antigua and Barbuda, Belarus, Eswatini, Dominica, Paraguay, Ireland, Serbia. A well-built logistics connection and a partnership network help us to send our elements anywhere in the planet with no delay without undermining product quality.
A specific source of honor for FAMAGA is its workers, each of whom contributes to common cause. We request into our team only professionals, who already have experience in the sphere of manufacturing equipment.
All spare parts from FAMAGA are guaranteed - we are responsible for the aftereffect of our work. Now, more than 10 million units of products have been delivered, and this amount is increasing every day. We are happy that buyers choose FAMAGA again and again, and we are pleased to make more developed and technologically innovative industrial equipment so as to stay on the top.
To consult or make a request, phone us or send a message to the online chat on our site. You can also direct a list of the necessary equipment to the email of organization - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
MGB-L1... | The locking arm is held in the locked position by spring force and is unlocked by solenoid force (closed-circuit current principle, mechanically locked). |
OD | ON when the door is closed |
OT | Bolt tongue inserted in the evaluation module |
OL | Guard locking solenoid in locked position |
OI | Diagnostics, there is a fault |
S1 | 1 NO contact, blue, illuminated |
S2 | 1 NO contact, white, illuminated (symbol: Unlocked) |
S3 | 1 NO contact, white, illuminated (symbol: Locked) |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 0,75 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN left |
Switching frequency | 0,25 Hz |
Connection | Plug connector RC18 |
Guard locking principle | Closed-circuit current principle |
Locking force FZh | 2000 N |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Solenoid control input IMP1, IMP2, IMM | |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.375 mA |
Safety outputs FO1A, FO1B | |
Test pulses | max.1 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
Controls and indicators | |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Belegungsschema | L1 |
Position 1 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | |
Farbe | Blue |
Schaltelement | 1NO |
Position 2 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | Printed |
Farbe | white |
Schaltelement | 1NO |
Position 3 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | Printed |
Farbe | white |
Schaltelement | 1NO |
Product version number | V3.0.3 |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Control of the guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 2.8 x 10-9 |
Mission time | 20 y |