We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are seeking Euchner MGB-L2H-ARA-R-114691 114691, call FAMAGA, the world's central distributor of factory-made equipment. Our company has operated for more than ten years - these are years of experience, which are symbolized in the quality of items and particular attention to each consumer. We value everyone, who engaged with us - so, our regular buyers accept the most convenient purchase conditions and discounts on the factory-made equipment market. At present, there are more than 4 thousand such purchasers, and we constantly sign new agreements. More than 600 purchases are terminated per day, because FAMAGA works all over the planet Germany, United Kingdom, Slovenia, Madagascar, Belarus, Luxembourg, Togo, Papua New Guinea, North Korea, Myanmar, Libya, Peru, Syria, Afghanistan, Pakistan, Suriname, Bolivia, Nigeria, Eritrea, Dominica, Gambia, Yemen, Singapore, Comoros, Angola, Ireland, China, Egypt, Lithuania, Albania, Fiji, East Timor, Burundi, Botswana, Tunisia, Costa Rica, Sierra Leone, United Arab Emirates, Hungary, Jamaica, Kazakhstan, Samoa, Vietnam, The Gambia, Sweden. A well-shaped logistics bond and a partnership network assist us to ship our elements anywhere in the planet promptly without discrediting product quality.
A special source of repute for FAMAGA is its personnel, each of whom contributes to common cause. We call into our team only professionals, who already have experience in the sphere of manufacturing equipment.
All outcomes from FAMAGA are assured - we are responsible for the cause of our work. At the moment, more than 10 million units of products have been delivered, and this amount is amounting every day. We are happy that purchasers choose FAMAGA again and again, and we are eager to make more developed and technologically innovative industrial equipment so as to stay on the top.
To ask a question or book, call us by phone or write to the online chat on our site. You can also direct a list of the necessary equipment to the email of corporation - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
MGB-L2... | The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle, electrically locked). |
OD | ON when the door is closed |
OT | Bolt tongue inserted in the evaluation module |
OL | Guard locking solenoid in locked position |
OI | Diagnostics, there is a fault |
S1 | 2 positively driven NC contacts and 1 NO contact (e.g. monitoring contact), emergency stop with turn-to-reset, not illuminated |
H2 | LED, green |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 0,75 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN right |
Switching frequency | 0,25 Hz |
Connection | Cable entries M20x1.5 |
Guard locking principle | Open-circuit current principle |
Locking force FZh | 2000 N |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connection cross-section | |
(Rigid/flexible) | 0,13 ... 1,5 mm? (AWG 24 ... AWG 16) |
(Rigid/flexible) with cable end sleeve according to DIN 46 228/1 | 0,25 ... 1,5 mm? |
(Rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 | 0,25 ... 0,75 mm? |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.375 mA |
Safety outputs FO1A, FO1B | |
Test pulses | max.1 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
Controls and indicators | |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Emergency stop | |
Switching voltage | 5 ... 24 V |
Switching current | 1 ... 100 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Solenoid control input IMP1, IMP2, IMM | |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
Product version number | V3.0.3 |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Emergency stop | |
B10D | |
Emergency stop | 0,065 x 106 |
Mission time | 20 y |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 1,00 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP65 |
Installation orientation | Door hinge DIN right |
Product version number | V3.0.0 |