We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are looking for Euchner CES-I-AP-U-C14-U20-158632 158632, get in touch with FAMAGA, the world's dominant retailer of industrial equipment. Our company has progressed for more than ten years - these are years of experience, which are illustrated in the quality of outputs and special attention to each client. We esteem everyone, who cooperated with us - thus, our regular purchasers bring in the most favorable purchase terms and discounts on the factory-made equipment market. Today, there are more than 4500 such buyers, and we constantly arrange new agreements. More than 600 purchases are terminated per day, because FAMAGA delivers all over the earth Germany, United Kingdom, Eritrea, Cyprus, Vietnam, Azerbaijan, Indonesia, Angola, Congo, Fiji, Equatorial Guinea, The Bahamas, Morocco, Bahamas, Greece, United Arab Emirates, Antigua and Barbuda, Burma, Swaziland, Ireland, Peru, Laos, Madagascar, Senegal, Botswana, Sweden, Nepal, Togo, Bolivia, Kazakhstan, Benin, Haiti, United States, Mauritius, Comoros, Armenia, Tonga, Qatar, Turkey, Costa Rica, Burkina Faso, Suriname, Luxembourg, Central African Republic. A well-elaborated logistics system and a partnership network help us to send our items anywhere in the earth promptly without damaging product quality.
A specific source of honor for FAMAGA is its team members, each of whom contributes to common cause. We invite into our team only specialists, who already have experience in the sphere of manufacturing equipment.
All items from FAMAGA are affirmed - we are responsible for the cause of our work. At the moment, more than 10 million units of products have been delivered, and this amount is ascending every day. We are glad that purchasers choose FAMAGA again and again, and we are glad to make more developed and technologically innovative industrial equipment so as stay in control.
To request or book, call us by phone or send a message to the online chat on our site. You can also dispatch a list of the needful equipment to the email of corporation - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
STATE | Status LED |
DIA | Diagnostic LED |
Designation | Function | Conductor coloring of connecting cable |
---|---|---|
UB | Power supply, DC 24 V | BN |
FO1A | Safety output, channel 1 | WH |
0V | Ground, DC 0 V | BU |
FO1B | Safety output, channel 2 | BK |
OD | Monitoring output | GY |
Housing material | Two-component epoxy resin |
Weight | |
Net | 0,7 kg |
Ambient temperature | |
At UB = DC 24 V | 0 ... +50 °C |
Cable static | -40 ... 80 °C |
Cable dynamic | -25 ... 80 °C |
Degree of protection | IP65 / IP67 / IP69 / IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting method | Surface mounting on metal |
Mounting distance | |
Between 2 switches or 2 actuators | min.150 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | 2 Nm |
Ready delay | 10 s |
Switching frequency | max.1 Hz |
Connection | connection cable PUR, length 20m |
Bending radius | |
static | 5 x cable diameter |
Dynamic | 10 x cable diameter |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV |
Current consumption | max.35 mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.400 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | |
Delay per device | max.260 ms |
Monitoring output OD | |
Type of output | Monitoring, semiconductor output, p-switching, short circuit-proof |
Switching current | max.50 mA |
Output voltage | 0,8 x UB ... UB V DC |
Safety outputs FO1A / FO1B | |
Test pulses | max.1,0 ms |
Test-pulse interval | min.140 ms |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 200 mA |
Output voltage | |
HIGH U (FO1A1) / U (FO1B) | UB-1,5V ... UB V DC |
LOW U (FO1A1) / U (FO1B) | 0 ... 1 V DC |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24 V 150 mA |
Rated conditional short-circuit current | 100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-9 |
Mission time | 20 |
Switch-on distance | |
Installation position A / in z direction | max.24 mm ALU |
max.22 mm PVC | |
Installation position D / in z direction | max.23 mm ALU |
max.18 mm PVC | |
Assured switch-off distance Sar | |
Installation position A / in y direction | max.72 mm |
Installation position A / in x/z direction | max.64 mm |
Installation position D / in y direction | max.68 mm |
Installation position D / in x/z direction | max.58 mm |
Assured operating distance Sao | |
Installation position A / in z direction | max.10 mm ALU |
Installation position D / in z direction | max.5 mm PVC |
Installation position A / in z direction | max.11 mm PVC |
Installation position D / in z direction | max.6 mm ALU |