Specifications CES-I-BR-U-C07-SA-157920 157920

If you are looking for Euchner CES-I-BR-U-C07-SA-157920 157920, make contact with FAMAGA, the world's dominant supplier of industrialized equipment. Our company has worked for more than ten years - these are cycles of experience, which are outlined in the quality of outputs and personalseparate attention to each buyer. We praise everyone, who worked with us - hence, our regular customers get the most desirable purchase conditions and discounts on the manufacturing equipment market. Nowadays, there are more than 4 thousand such consumers, and we constantly compose new agreements. More than 750 agreements are achieved per day, because FAMAGA works all over the globe . A advanced logistics system and a partnership network cheer us to send our units anywhere in the planet with no delay without compromising product quality.

A specific source of dignity for FAMAGA is its workers, each of whom contributes to common cause. We accept into our team only specialists, who already have experience in the range of manufacturing equipment.

All products from FAMAGA are guaranteed - we are responsible for the result of our work. Nowadays, more than 10 million units of products have been delivered, and this quantity is growing every day. We are happy that purchasers choose FAMAGA again and again, and we are pleased to make more progressive and technologically innovative industrial equipment so as to stay on the top.

To get some advice or order, get in touch with us or write a message to the online chat on our site. You can also dispatch a list of the necessary equipment to the email of organization - we will contact you ourselves with a worked out commercial proposal from FAMAGA.

Features CES-I-BR-U-C07-SA-157920 157920

  • Safety switch with integrated evaluation electronics
  • Series connection (full diagnostics possible in combination with ESM-CB)
  • Switch chains up to 200 m long
  • Up to 20 switches in series
  • Short circuit monitoring
  • Two safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Three active faces
  • Plug connector M12, 8-pin (aligned)
  • Unicode
Installation position Permissible installation position Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Category according to EN 13849-1 Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN 13849-1
Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated. LED indicator
STATEStatus LED
DIADiagnostic LED
Terminal assignment
Pin Designation Function
1 FI1B Enable input for channel 2
2 UB Power supply, DC 24 V
3 FO1A Safety output, channel 1
4 FO1B Safety output, channel 2
5 OD/C Monitoring output/communication
6 FI1A Enable input for channel 1
7 0V Ground, DC 0 V
8 nc n.c.
Notice The caps for the mounting holes are included.
Dimensions 40 x 26.5 x 18
Housing material Plastic, PBT-PC-GF30
Weight
Net 0,03 kg
Ambient temperature
At UB = 24 V DC -25 ... +55 °C
Degree of protection IP65 / IP67 / IP69 / IP69K
Resilience to vibration In acc. with EN IEC 60947-5-2
Mounting method Surface mounting on metal
Mounting distance
between the switches min.140 mm
Installation orientation Any
Tightening torque max.0,8 Nm
Ready delay 5 s
Switching frequency max.1 Hz
Connection M12 plug connector, 8-pin
Electrical connection ratings
Operating voltage DC
UB 24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV
Rated conditional short-circuit current 100 A
Current consumption 40 mA
Fusing
External (operating voltage) 0,25 ... 8 A
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In acc. with EN IEC 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Switch-on time
Safety outputs max.100 ms
Safety class III
Risk time according to EN 60947-5-3
Delay per device 10 ms
Single device max.125 ms
Monitoring output OD/C
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage UB-1,5V ... UB V DC
Safety outputs FO1A / FO1B
Test pulses 0,3 ms
Test-pulse interval ca 100 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Switching current 1 ... 150 mA
Output voltage
HIGH U(FO1A) / U(FO1B) UB-1,5V ... UB V DC
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
Utilization category according to EN 60947-5-2
DC-13 24V 150mA
Off-state current Ir max.0,25 mA
Discrepancy time max.10 ms
Work area
Repeat accuracy R ? 10
Other
Additional feature Caps included
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 6 x 10E-10
Mission time 20 y
In combination with Actuator CES-A-BDN-06-158210Operating distance
Switch-on distance
Installation position A 13 mm
Installation position C 8 mm
Installation position B 11 mm
Installation position D 7 mm
Assured switch-off distance Sar
in x direction/installation position A max.24 mm
in x direction/installation position C max.21 mm
Assured operating distance Sao
in x direction/installation position A min.13 mm
in x direction/installation position C min.6 mm
In combination with Actuator CES-A-BTN-C07-156230, CES-A-BDN-06-158210Operating distance
Switching hysteresis min.1 mm
In combination with Actuator CES-A-BTN-C07-156230Operating distance
Switch-on distance
Installation position C + D 7 mm
Installation position A + B 13 mm
Assured switch-off distance Sar
in x direction/installation position A + B max.20 mm
in x direction/installation position C + D max.17 mm
Assured operating distance Sao
in x direction/installation position A min.10 mm
in x direction/installation position B min.9 mm
in x direction/installation position C min.3 mm
in x direction/installation position D min.2 mm