LCA-4TR-50-1660-AP-156570 Euchner 156570
 LCA-4TR-50-1660-AP-156570 Euchner 156570

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

LCA-4TR-50-1660-AP-156570 156570 Euchner

Manufacturer

Euchner

Country

Germany

Name

LCA-4TR-50-1660-AP-156570

Part number

156570

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications LCA-4TR-50-1660-AP-156570 156570

If you are questing Euchner LCA-4TR-50-1660-AP-156570 156570, call FAMAGA, the world's chief company of industrialized equipment. Our company has worked for more than ten years - these are cycles of experience, which are represented in the quality of products and individual attention to each buyer. We value everyone, who liased with us - therefore, our regular clients get the most attractive purchase conditions and discounts on the industrial equipment market. At present, there are more than 4500 such buyers, and we constantly compose new agreements. More than 650 purchases are terminated per day, because FAMAGA supplies all over the planet . A advanced logistics network and a partnership network assist us to deliver our goods anywhere in the earth on-time without undermining product quality.

A particular source of honor for FAMAGA is its workers, each of whom contributes to our work. We propose into our team only experts, who already have experience in the sphere of machine made streamlined equipment.

All outcomes from FAMAGA are ensured - we are responsible for the aftereffect of our work. Now, more than 10 million units of products have been provided, and this number is increasing every day. We are glad that clients choose FAMAGA again and again, and we are pleased to make more advanced and technologically advanced industrial equipment so as keep on top of it.

To ask a question or make a request, call us by phone or write to the online chat on our site. You can also direct a list of the needful equipment to the email of our company - we will contact you ourselves with a made commercial proposal from FAMAGA.

Features LCA-4TR-50-1660-AP-156570 156570

  • Resolution 50 mm
  • Protective field height 1,660 mm
  • Range 12 m
  • With plug connector M12
  • Two safety outputs (OSSD)
  • Installation material is included with the product
Protective function Body protection (arms / legs) LED function display Transmitter Receiver
LED OKNormal operation
LED ERRORFault state
LED STOPStop state
LED TESTTest function
LED STARTStart/ restart
Pin assignment transmitter
Plug connector (view of connection side) Pin Designation Function Conductor coloring of connection cable
1 24 V DCB Operating voltage, 24 V DC BN
2 RANGE 0 Device configuration, corresponds to the standard EN 61131-2 WH
3 0 V DC Operating voltage, 0 V DC BU
4 RANGE 1 Device configuration, corresponds to the standard EN 61131-2 BK
5 FE Function earth (must be connected to meet the EMC requirements) GY
Connector assignment receiver
Plug connector (view of connection side) Pin Designation Function Conductor coloring of connection cable
1 FO1AB Safety output, channel 1 WH
2 24 V DC Operating voltage, 24 V DC BN
3 FO1B Safety output, channel 2 GN
4 K1_K2/RESTART Feedback external contactors YE
5 SEL_A Device configuration GY
6 SEL_B Device configuration PK
7 0 V DC Operating voltage, 0 V DC BU
8 FE Function earth (must be connected to meet the EMC requirements) RD
Number of safety outputs 2 Static, self-monitoring PNP safety outputs
Resolution 50 mm
Height of the protective field 1660 mm
Height of the sensor 1713 mm
Maximum length of connecting cables 100 m
Range of the protective field 12000 mm
Dimensions 28x30 mm
Ambient temperature -30 ... 55 °C
Degree of protection IP 65 / IP 67
Installation orientation Any
Reaction time 12 ms
Connection Plug connector M12 (5-pin transmitter / 8-pin receiver)
Electrical connection ratings
Cascadable No
Muting possible In combination with external sensors and an evaluation unit
Operating voltage DC 24 V DC -20% ... +20%
Current consumption 400 mA
Power consumption
Transmitter 1 W
Receiver 2 W
LED indicator Yes
Reliability values according to EN ISO 13849-1
ESPE type 4
Performance Level PL e
PFHD 1,44x10-8
Safety Integrity Level SIL 3 / SILCL 3
Mission time 20 y