CES-I-BR-M-C07-SA-156233 Euchner 156233
 CES-I-BR-M-C07-SA-156233 Euchner 156233

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

CES-I-BR-M-C07-SA-156233 156233 Euchner

Manufacturer

Euchner

Country

Germany

Name

CES-I-BR-M-C07-SA-156233

Part number

156233

Description

CES-I-BR-M-C07-SA-156233

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications CES-I-BR-M-C07-SA-156233 156233

If you are seeking Euchner CES-I-BR-M-C07-SA-156233 156233, call FAMAGA, the world's chief distributor of manufacturing equipment. Our company has existed for more than ten years - these are cycles of experience, which are symbolized in the quality of items and individual attention to each buyer. We admire everyone, who joined with us - so, our regular customers accept the most convenient purchase conditions and discounts on the manufacturing equipment market. Now, there are more than 4 thousand such clients, and we constantly arrange new agreements. More than 750 agreements are achieved per day, because FAMAGA works all over the planet . A advanced logistics chains and a partnership network assist us to ship our products anywhere in the planet as soon as possible without damaging product quality.

A special source of repute for FAMAGA is its employees, each of whom contributes to common cause. We propose into our team only specialists, who already have experience in the direction of machine made streamlined equipment.

All merchandises from FAMAGA are guaranteed - we are responsible for the outcome of our work. At the moment, more than 10 million units of products have been provided, and this quantity is growing every day. We are happy that customers choose FAMAGA again and again, and we are glad to make more progressive and technologically advanced industrial equipment so as to stay on the top.

To consult or place an order, call us by phone or write to the online chat on our site. You can also direct a list of the necessary equipment to the email of our company - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.

Features CES-I-BR-M-C07-SA-156233 156233

  • Safety switch with integrated evaluation electronics
  • Series connection (full diagnostics possible in combination with ESM-CB)
  • Switch chains up to 200 m long
  • Up to 20 switches in series
  • Short circuit monitoring
  • Two safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Three active faces
  • Plug connector M12, 8-pin (aligned)
  • Multicode
Installation position Permissible installation position Multicode evaluation Every suitable actuator is detected by the switch. Category according to EN 13849-1 Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN 13849-1
Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated. LED indicator
STATEStatus LED
DIADiagnostic LED
Terminal assignment
Pin Designation Function
1 FI1B Enable input for channel 2
2 UB Power supply, DC 24 V
3 FO1A Safety output, channel 1
4 FO1B Safety output, channel 2
5 OD/C Monitoring output/communication
6 FI1A Enable input for channel 1
7 0V Ground, DC 0 V
8 nc n.c.
Notice The caps for the mounting holes are included.
Dimensions 40 x 26.5 x 18
Housing material Plastic, PBT-PC-GF30
Weight
Net 0,03 kg
Ambient temperature
At UB = 24 V DC -25 ... +55 °C
Degree of protection IP65 / IP67 / IP69 / IP69K
Resilience to vibration In acc. with EN IEC 60947-5-2
Mounting method Surface mounting on metal
Mounting distance
between the switches min.140 mm
Installation orientation Any
Tightening torque max.0,8 Nm
Ready delay 5 s
Switching frequency max.1 Hz
Connection M12 plug connector, 8-pin
Electrical connection ratings
Operating voltage DC
UB 24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV
Rated conditional short-circuit current 100 A
Current consumption 40 mA
Fusing
External (operating voltage) 0,25 ... 8 A
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In acc. with EN IEC 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Switch-on time
Safety outputs max.100 ms
Safety class III
Risk time according to EN 60947-5-3
Delay per device 10 ms
Single device max.125 ms
Monitoring output OD/C
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage UB-1,5 ... UB V DC
Safety outputs FO1A / FO1B
Test pulses 0,3 ms
Test-pulse interval ca 100 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Switching current 1 ... 150 mA
Output voltage
HIGH U(FO1A) / U(FO1B) UB-1,5V ... UB V DC
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
Utilization category according to EN 60947-5-2
DC-13 24V 150mA
Off-state current Ir max.0,25 mA
Discrepancy time max.10 ms
Work area
Repeat accuracy R ? 10
Other
Additional feature Caps included
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 6 x 10E-10
Mission time 20 y
In combination with Actuator CES-A-BTN-C07-156230Operating distance
Switch-on distance
Installation position A + B 13 mm
Installation position C + D 7 mm
Assured switch-off distance Sar
in x direction/installation position C + D max.17 mm
in x direction/installation position A + B max.20 mm
Assured operating distance Sao
in x direction/installation position A min.10 mm
in x direction/installation position B min.9 mm
in x direction/installation position C min.3 mm
in x direction/installation position D min.2 mm
In combination with Actuator CES-A-BTN-C07-156230, CES-A-BDN-06-158210Operating distance
Switching hysteresis min.1 mm
In combination with Actuator CES-A-BDN-06-158210Operating distance
Switch-on distance
Installation position A 13 mm
Installation position C 8 mm
Installation position B 11 mm
Installation position D 7 mm
Assured switch-off distance Sar
in x direction/installation position A max.24 mm
in x direction/installation position C max.21 mm
Assured operating distance Sao
in x direction/installation position C min.6 mm
in x direction/installation position A min.13 mm