We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CTP-L1-AP-U-HA-AE-SA-126912
Part number
126912
Description
SAFETY SWITCH, CTP-L1-AP-U-HA-AE-SA
Stock availability:
On request
If you are questing Euchner CTP-L1-AP-U-HA-AE-SA-126912 126912, get in touch with FAMAGA, the world's primary retailer of factory-made equipment. Our company has advanced for more than ten years - these are ages of experience, which are illustrated in the quality of items and particular attention to each consumer. We respect everyone, who conspired with us - thus, our regular customers bring in the most desirable purchase forms and discounts on the factory-made equipment market. At this time, there are more than 4 thousand such purchasers, and we constantly form new agreements. More than 700 contracts are concluded per day, because FAMAGA delivers all over the planet Germany, United Kingdom, Bahrain, Italy, New Zealand, Vietnam, Brazil, Sierra Leone, Colombia, Costa Rica, Rwanda, Egypt, Andorra, Namibia, Fiji, Malawi, Niger, South Sudan, Sweden, Mauritania, Samoa, Cape Verde, Philippines, Mongolia, Turkey, United States, Iran, South Korea, The Gambia, Comoros, Luxembourg, Cameroon, Dominica, Chile, Lithuania, Pakistan, Jamaica, Djibouti, East Timor, Mauritius, Ukraine, Madagascar, Estonia. A well-shaped logistics bond and a partnership network let us to deliver our units anywhere in the planet quickly without compromising product quality.
A particular source of pride for FAMAGA is its staff members, each of whom contributes to common cause. We call into our team only professionals, who already have experience in the range of manufacturing equipment.
All merchandises from FAMAGA are guaranteed - we are responsible for the result of our work. Nowadays, more than 10 million units of products have been supplied, and this amount is rising every day. We are happy that users choose FAMAGA again and again, and we strive to make more exceptional and technologically innovative industrial equipment so as stay in control.
To consult or order, contact us or write a message to the online chat on our site. You can also dispatch a list of the necessary equipment to the email of firm - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
CTP?L1 | Guard locking actuated by spring force applied and power-ON released (closed-circuit current principle) |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connecting cable |
---|---|---|---|---|
1 | IMP | Operating voltage of guard locking solenoid 24 V DC | WH | |
2 | UB | Operating voltage of AP electronics 24 V DC | BN | |
3 | FO1A | Safety output, channel 1 | GN | |
4 | FO1B | Safety output, channel 2 | YE | |
5 | OI | Diagnostic output | GY | |
6 | OD | Door monitoring output | PK | |
7 | 0 V UB | Operating voltage of AP electronics 0 V | BU | |
8 | IMM | Operating voltage of guard locking solenoid 0 V | RD |
Housing material | |
Switch head cover | Die-cast zinc |
Safety switch housing | Fiber glass reinforced thermoplastic |
Weight | |
Net | 0,42 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... +55 °C |
Degree of protection | IP67 / IP69 / IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | max.1 s |
Switching frequency | max.0,5 Hz |
Connection | 1 plug connector M12, 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Retention force | 20 N |
Extraction force | 20 N |
Actuating force | 10 N |
Overtravel | 5 mm |
Test-pulse interval | min.100 ms |
Test pulses | max.0,3 ms |
Operating voltage DC | |
UUB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 2 A |
External (solenoid operating voltage IMP) | 0,5 ... 8 A |
Rated insulation voltage Ui | max.50 V |
Rated impulse withstand voltage Uimp | max.0,5 kV |
Power consumption | 6 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs FO1A / FO1B | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output FO1A / FO1B | 1 ... 150 mA |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1,5 ... UB V DC |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Switch-on time | max.400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms In acc. with EN IEC 60947-5-3 |
Monitoring output OD | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OI | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Repeat accuracy R | 10 % |
Additional feature | Escape release actuated by pushing |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Performance Level | PL e |
Category | 4 |
PFHD | 4.1 x 10 -9 |
Mission time | 20 y |