CES-I-AR-M-C04-U20-119477 Euchner 119477
 CES-I-AR-M-C04-U20-119477 Euchner 119477

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

CES-I-AR-M-C04-U20-119477 119477 Euchner

Manufacturer

Euchner

Country

Germany

Name

CES-I-AR-M-C04-U20-119477

Part number

119477

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications CES-I-AR-M-C04-U20-119477 119477

If you are seeking Euchner CES-I-AR-M-C04-U20-119477 119477, call FAMAGA, the world's main supplier of industrialized equipment. Our company has progressed for more than ten years - these are cycles of experience, which are symbolized in the quality of items and special attention to each customer. We admire everyone, who conspired with us - so, our regular clients receive the most acceptable purchase forms and discounts on the manufacturing equipment market. Nowadays, there are more than 4 thousand such buyers, and we constantly sign new agreements. More than 750 agreements are achieved per day, because FAMAGA works all over the planet . A well-elaborated logistics link and a partnership network cheer us to ship our goods anywhere in the planet promptly without discrediting product quality.

A particular source of repute for FAMAGA is its workers, each of whom contributes to common cause. We invite into our team only specialists, who already have experience in the direction of machine made streamlined equipment.

All spare parts from FAMAGA are ensured - we are responsible for the cause of our work. At this moment, more than 10 million units of products have been provided, and this quantity is increasing every day. We are happy that purchasers choose FAMAGA again and again, and we are eager to make more progressive and technologically advanced industrial equipment so as to stay on the top.

To inquire or book, get in touch with us or write a message to the online chat on our site. You can also direct a list of the necessary equipment to the email of corporation - we will contact you ourselves with a made commercial proposal from FAMAGA.

Features CES-I-AR-M-C04-U20-119477 119477

  • Safety switch with integrated evaluation electronics
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Three active faces
  • Connection cable PUR, 20 m, flying lead, 8-core
  • Multicode
Multicode evaluation Every suitable actuator is detected by the evaluation unit. Category according to EN 13849-1 Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated. LED indicator
STATEStatus LED
DIADiagnostics LED
Terminal assignment
Designation Function Conductor coloring of connection cable
FI1B Enable input for channel 2 WH
UB Power supply, DC 24 V BN
FO1A Safety output, channel 1 GN
FO1B Safety output, channel 2 YE
OD Monitoring output GY
FI1A Enable input for channel 1 PK
0V Ground, DC 0 V BU
RST Reset input RD
Material
Rubber support NBR 80 ±5 Shore
Housing material Plastic, PBT
Weight
Net 0,7 kg
Ambient temperature
Cable static -25 ... 65 °C
Cable dynamic -25 ... 65 °C
Degree of protection IP67
Resilience to vibration In acc. with EN IEC 60947-5-2
Mounting method Surface mounting on metal
Mounting distance
Between 2 switches or 2 actuators min.140 mm
Installation orientation Any
Tightening torque
Fixing screws max.0,8 Nm
Ready delay 10 s
Switching frequency max.1 Hz
Connection connection cable PUR, length 20m
Bending radius
static 5 x cable diameter
Dynamic 10 x cable diameter
Electrical connection ratings
Operating voltage DC
UB 24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV
Current consumption max.35 mA
Fusing
External (operating voltage) 0,25 ... 8 A
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In acc. with EN IEC 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Switch-on time
Safety outputs max.400 ms
Safety class III
Risk time according to EN 60947-5-3
Delay per device 5 ms
Single device max.260 ms
Monitoring output OD
Type of output Semiconductor output, p-switching, short circuit-proof
Switching current max.50 mA
Output voltage 0,8 x UB ... UB V DC
Safety outputs FO1A / FO1B
Test pulses max.1,0 ms
Test-pulse interval min.140 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Switching current
per safety output 1 ... 200 mA
Output voltage
HIGH U(FO1A) / U(FO1B) UB-1,5V ... UB V DC
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
Utilization category according to EN 60947-5-2
DC-13 24V 200mA
Rated conditional short-circuit current 100 A
Off-state current Ir max.0,25 mA
Discrepancy time max.10 ms
Work area
Repeat accuracy R ? 10
Other
Additional feature Rubber support included
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 4.1 x 10-9
Mission time 20
In combination with Actuator CES-A-BDN-06-104730Operating distance
Switch-on distance
Approach direction C or D (broad side) 15 mm
Approach direction A or B (front side) 19 mm
Assured operating distance Sao
Approach direction C or D (broad side) min.10 mm
Approach direction A or B (front side) min.14 mm
In combination with Actuator CES-A-BBN-C04-115271Operating distance
Switch-on distance
Approach direction C or D (broad side) 11 mm
Approach direction A or B (front side) 15 mm
Assured operating distance Sao
Approach direction A or B (front side) 10
Approach direction C or D (broad side) 6
In combination with Actuator CES-A-BDN-06-104730, CES-A-BBN-C04-115271Operating distance
Assured switch-off distance Sar
In y direction max.60 mm
In x/z direction max.40 mm
Switching hysteresis min.1 mm