We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are seeking Euchner CES-I-AR-M-C04-U20-119477 119477, call FAMAGA, the world's main supplier of industrialized equipment. Our company has progressed for more than ten years - these are cycles of experience, which are symbolized in the quality of items and special attention to each customer. We admire everyone, who conspired with us - so, our regular clients receive the most acceptable purchase forms and discounts on the manufacturing equipment market. Nowadays, there are more than 4 thousand such buyers, and we constantly sign new agreements. More than 750 agreements are achieved per day, because FAMAGA works all over the planet Germany, United Kingdom, Panama, Lesotho, Vietnam, Zambia, Eswatini, Equatorial Guinea, Saudi Arabia, Congo, The Gambia, Iceland, Nigeria, Dominica, Gambia, Kazakhstan, Burkina Faso, Ghana, Denmark, Georgia, Malawi, Australia, Argentina, Uzbekistan, India, Mongolia, Tunisia, Guatemala, Nicaragua, Liechtenstein, Mali, Kenya, Peru, Turkey, Estonia, Belize, Nepal, Hungary, Ukraine, North Korea, Andorra, Iran, Bosnia and Herzegovina, Comoros, Austria, Zimbabwe, Moldova, Philippines. A well-elaborated logistics link and a partnership network cheer us to ship our goods anywhere in the planet promptly without discrediting product quality.
A particular source of repute for FAMAGA is its workers, each of whom contributes to common cause. We invite into our team only specialists, who already have experience in the direction of machine made streamlined equipment.
All spare parts from FAMAGA are ensured - we are responsible for the cause of our work. At this moment, more than 10 million units of products have been provided, and this quantity is increasing every day. We are happy that purchasers choose FAMAGA again and again, and we are eager to make more progressive and technologically advanced industrial equipment so as to stay on the top.
To inquire or book, get in touch with us or write a message to the online chat on our site. You can also direct a list of the necessary equipment to the email of corporation - we will contact you ourselves with a made commercial proposal from FAMAGA.
STATE | Status LED |
DIA | Diagnostics LED |
Designation | Function | Conductor coloring of connection cable |
---|---|---|
FI1B | Enable input for channel 2 | WH |
UB | Power supply, DC 24 V | BN |
FO1A | Safety output, channel 1 | GN |
FO1B | Safety output, channel 2 | YE |
OD | Monitoring output | GY |
FI1A | Enable input for channel 1 | PK |
0V | Ground, DC 0 V | BU |
RST | Reset input | RD |
Material | |
Rubber support | NBR 80 ±5 Shore |
Housing material | Plastic, PBT |
Weight | |
Net | 0,7 kg |
Ambient temperature | |
Cable static | -25 ... 65 °C |
Cable dynamic | -25 ... 65 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting method | Surface mounting on metal |
Mounting distance | |
Between 2 switches or 2 actuators | min.140 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | max.0,8 Nm |
Ready delay | 10 s |
Switching frequency | max.1 Hz |
Connection | connection cable PUR, length 20m |
Bending radius | |
static | 5 x cable diameter |
Dynamic | 10 x cable diameter |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV |
Current consumption | max.35 mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.400 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.260 ms |
Monitoring output OD | |
Type of output | Semiconductor output, p-switching, short circuit-proof |
Switching current | max.50 mA |
Output voltage | 0,8 x UB ... UB V DC |
Safety outputs FO1A / FO1B | |
Test pulses | max.1,0 ms |
Test-pulse interval | min.140 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 200 mA |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1,5V ... UB V DC |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated conditional short-circuit current | 100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
Additional feature | Rubber support included |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-9 |
Mission time | 20 |
Switch-on distance | |
Approach direction C or D (broad side) | 15 mm |
Approach direction A or B (front side) | 19 mm |
Assured operating distance Sao | |
Approach direction C or D (broad side) | min.10 mm |
Approach direction A or B (front side) | min.14 mm |
Switch-on distance | |
Approach direction C or D (broad side) | 11 mm |
Approach direction A or B (front side) | 15 mm |
Assured operating distance Sao | |
Approach direction A or B (front side) | 10 |
Approach direction C or D (broad side) | 6 |
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Switching hysteresis | min.1 mm |