We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are looking for Euchner CES-I-AR-M-C04-U10-119476 119476, make contact with FAMAGA, the world's top retailer of machine made equipment. Our company has lasted for more than ten years - these are years of experience, which are described in the quality of products and individual attention to each purchaser. We value everyone, who worked with us - thus, our regular consumers bring in the most attractive purchase conditions and discounts on the factory-made equipment market. At this time, there are more than 4500 such clients, and we constantly compose new agreements. More than 600 purchases are terminated per day, because FAMAGA delivers all over the earth Germany, United Kingdom, Eswatini, Italy, Norway, Finland, United Arab Emirates, Costa Rica, Netherlands, Cuba, Antigua and Barbuda, Serbia, Luxembourg, Uganda, The Bahamas, Latvia, Israel, Madagascar, Panama, Tunisia, Eritrea, Morocco, United States, Guyana, Cape Verde, Peru, Jamaica, Niger, Liechtenstein, Fiji, Botswana, Bolivia, Laos, Swaziland, Nigeria, Australia, Burkina Faso, Togo, Malaysia, Cyprus, Nepal, El Salvador, Paraguay, Afghanistan, Sierra Leone, Ireland, Malta. A advanced logistics connection and a partnership network assist us to send our units anywhere in the earth as soon as possible without undermining product quality.
A special source of honor for FAMAGA is its staff members, each of whom contributes to common cause. We propose into our team only experts, who already have experience in the sphere of manufacturing equipment.
All products from FAMAGA are verified - we are responsible for the outcome of our work. Now, more than 10 million units of products have been delivered, and this amount is rising every day. We are glad that customers choose FAMAGA again and again, and we are pleased to make more developed and technologically innovative industrial equipment so as stay in control.
To get some advice or place an order, phone us or write to the online chat on our site. You can also dispatch a list of the needful equipment to the email of our company - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
STATE | Status LED |
DIA | Diagnostics LED |
Designation | Function | Conductor coloring of connection cable |
---|---|---|
FI1B | Enable input for channel 2 | WH |
UB | Power supply, DC 24 V | BN |
FO1A | Safety output, channel 1 | GN |
FO1B | Safety output, channel 2 | YE |
OD | Monitoring output | GY |
FI1A | Enable input for channel 1 | PK |
0V | Ground, DC 0 V | BU |
RST | Reset input | RD |
Material | |
Rubber support | NBR 80 ±5 Shore |
Housing material | Plastic, PBT |
Weight | |
Net | 0,36 kg |
Ambient temperature | |
Cable static | -25 ... 65 °C |
Cable dynamic | -25 ... 65 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting method | Surface mounting on metal |
Mounting distance | |
Between 2 switches or 2 actuators | min.140 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | max.0,8 Nm |
Ready delay | 10 s |
Switching frequency | max.1 Hz |
Connection | connection cable PUR, length 10m |
Bending radius | |
static | 5 x cable diameter |
Dynamic | 10 x cable diameter |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV |
Current consumption | max.35 mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.400 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.260 ms |
Monitoring output OD | |
Type of output | Semiconductor output, p-switching, short circuit-proof |
Switching current | max.50 mA |
Output voltage | 0,8 x UB ... UB V DC |
Safety outputs FO1A / FO1B | |
Test pulses | max.1,0 ms |
Test-pulse interval | min.140 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 200 mA |
Output voltage | |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
HIGH U(FO1A) / U(FO1B) | UB-1,5V ... UB V DC |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated conditional short-circuit current | 100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
Additional feature | Rubber support included |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-9 |
Mission time | 20 |
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Switching hysteresis | min.1 mm |
Switch-on distance | |
Approach direction C or D (broad side) | 15 mm |
Approach direction A or B (front side) | 19 mm |
Assured operating distance Sao | |
Approach direction C or D (broad side) | min.10 mm |
Approach direction A or B (front side) | min.14 mm |
Switch-on distance | |
Approach direction C or D (broad side) | 11 mm |
Approach direction A or B (front side) | 15 mm |
Assured operating distance Sao | |
Approach direction A or B (front side) | 10 |
Approach direction C or D (broad side) | 6 |