CES-I-AR-U-C04-U20-119472 Euchner 119472
 CES-I-AR-U-C04-U20-119472 Euchner 119472

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

CES-I-AR-U-C04-U20-119472 119472 Euchner

Manufacturer

Euchner

Country

Germany

Name

CES-I-AR-U-C04-U20-119472

Part number

119472

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications CES-I-AR-U-C04-U20-119472 119472

If you are seeking Euchner CES-I-AR-U-C04-U20-119472 119472, get in touch with FAMAGA, the world's central distributor of factory-made equipment. Our company has worked for more than ten years - these are ages of experience, which are illustrated in the quality of products and special attention to each consumer. We value everyone, who collaborated with us - thus, our regular clients accept the most attractive purchase terms and discounts on the factory-made equipment market. At this time, there are more than 4500 such buyers, and we constantly sign new agreements. More than 600 contracts are concluded per day, because FAMAGA delivers all over the earth . A well-elaborated logistics bond and a partnership network help us to ship our units anywhere in the earth on-time without discrediting product quality.

A specific source of repute for FAMAGA is its workers, each of whom contributes to common cause. We invite into our team only professionals, who already have experience in the sphere of manufacturing equipment.

All goods from FAMAGA are ensured - we are responsible for the outcome of our work. Now, more than 10 million units of products have been delivered, and this amount is increasing every day. We are glad that consumers choose FAMAGA again and again, and we are eager to make more developed and technologically innovative industrial equipment so as stay in control.

To inquire or place an order, phone us or send a message to the online chat on our site. You can also dispatch a list of the needful equipment to the email of our company - we will contact you ourselves with a worked out commercial proposal from FAMAGA.

Features CES-I-AR-U-C04-U20-119472 119472

  • Safety switch with integrated evaluation electronics
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Three active faces
  • Connection cable PUR, 20 m, flying lead, 8-core
  • Unicode
Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Category according to EN 13849-1 Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated. LED indicator
STATEStatus LED
DIADiagnostics LED
Terminal assignment
Designation Function Conductor coloring of connection cable
FI1B Enable input for channel 2 WH
UB Power supply, DC 24 V BN
FO1A Safety output, channel 1 GN
FO1B Safety output, channel 2 YE
OD Monitoring output GY
FI1A Enable input for channel 1 PK
0V Ground, DC 0 V BU
RST Reset input RD
Material
Rubber support NBR 80 ±5 Shore
Housing material Plastic, PBT
Weight
Net 0,7 kg
Ambient temperature
Cable dynamic -25 ... 65 °C
Cable static -25 ... 65 °C
Degree of protection IP67
Resilience to vibration In acc. with EN IEC 60947-5-2
Mounting method Surface mounting on metal
Mounting distance
Between 2 switches or 2 actuators min.140 mm
Installation orientation Any
Tightening torque
Fixing screws max.0,8 Nm
Ready delay 10 s
Switching frequency max.1 Hz
Connection connection cable PUR, length 20m
Bending radius
static 5 x cable diameter
Dynamic 10 x cable diameter
Electrical connection ratings
Operating voltage DC
UB 24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV
Current consumption max.35 mA
Fusing
External (operating voltage) 0,25 ... 8 A
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In acc. with EN IEC 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Switch-on time
Safety outputs max.400 ms
Safety class III
Risk time according to EN 60947-5-3
Delay per device 5 ms
Single device max.260 ms
Monitoring output OD
Type of output Semiconductor output, p-switching, short circuit-proof
Switching current max.50 mA
Output voltage 0,8 x UB ... UB V DC
Safety outputs FO1A / FO1B
Test pulses max.1,0 ms
Test-pulse interval min.140 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Switching current
per safety output 1 ... 200 mA
Output voltage
HIGH U(FO1A) / U(FO1B) UB-1,5V ... UB V DC
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
Utilization category according to EN 60947-5-2
DC-13 24V 200mA
Rated conditional short-circuit current 100 A
Off-state current Ir max.0,25 mA
Discrepancy time max.10 ms
Work area
Repeat accuracy R ? 10
Other
Additional feature Rubber support included
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 4.1 x 10-9
Mission time 20
In combination with Actuator CES-A-BDN-06-104730Operating distance
Switch-on distance
Approach direction A or B (front side) 19 mm
Approach direction C or D (broad side) 15 mm
Assured operating distance Sao
Approach direction C or D (broad side) min.10 mm
Approach direction A or B (front side) min.14 mm
In combination with Actuator CES-A-BDN-06-104730, CES-A-BBN-C04-115271Operating distance
Assured switch-off distance Sar
In y direction max.60 mm
In x/z direction max.40 mm
Switching hysteresis min.1 mm
In combination with Actuator CES-A-BBN-C04-115271Operating distance
Switch-on distance
Approach direction C or D (broad side) 11 mm
Approach direction A or B (front side) 15 mm
Assured operating distance Sao
Approach direction A or B (front side) 10
Approach direction C or D (broad side) 6