CES-I-AP-U-C04-U20-116505 Euchner 116505
 CES-I-AP-U-C04-U20-116505 Euchner 116505

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

CES-I-AP-U-C04-U20-116505 116505 Euchner

Manufacturer

Euchner

Country

Germany

Name

CES-I-AP-U-C04-U20-116505

Part number

116505

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications CES-I-AP-U-C04-U20-116505 116505

If you are seeking Euchner CES-I-AP-U-C04-U20-116505 116505, catch up with FAMAGA, the world's central provider of machine made equipment. Our company has functioned for more than ten years - these are ages of experience, which are outlined in the quality of goods and particular attention to each purchaser. We esteem everyone, who cooperated with us - thus, our regular purchasers procure the most beneficial purchase terms and discounts on the machine made streamlined equipment market. At present, there are more than 4 thousand such consumers, and we constantly make new agreements. More than 700 purchases are terminated per day, because FAMAGA works all over the planet . A well-built logistics chains and a partnership network assist us to ship our products anywhere in the planet promptly without damaging product quality.

A special source of dignity for FAMAGA is its team members, each of whom contributes to our work. We call into our team only professionals, who already have experience in the sphere of manufacturing equipment.

All items from FAMAGA are affirmed - we are responsible for the result of our work. Now, more than 10 million units of products have been delivered, and this bulk is amounting every day. We are happy that buyers choose FAMAGA again and again, and we are happy to make more exceptional and technologically innovative industrial equipment so as to stay on the top.

To get some advice or order, contact us or write to the online chat on our site. You can also direct a list of the necessary equipment to the email of corporation - we will contact you ourselves with a worked out commercial proposal from FAMAGA.

Features CES-I-AP-U-C04-U20-116505 116505

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Three active faces
  • Connection cable PUR, 20 m, flying lead
  • Unicode
  • Monitoring output OD
Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Category according to EN 13849-1 Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated. LED indicator
STATEStatus LED
DIADiagnostics LED
Terminal assignment
Designation Function Conductor coloring of connection cable
UB Power supply, DC 24 V BN
FO1A Safety output, channel 1 WH
0V Ground, DC 0 V BU
FO1B Safety output, channel 2 BK
OD Monitoring output GY
Material
Rubber support NBR 80 ±5 Shore
Housing material Plastic, PBT
Weight
Net 0,7 kg
Ambient temperature
Cable static -25 ... 65 °C
Cable dynamic -25 ... 65 °C
Degree of protection IP67
Resilience to vibration In acc. with EN IEC 60947-5-2
Mounting method Surface mounting on metal
Mounting distance
Between 2 switches or 2 actuators min.140 mm
Installation orientation Any
Tightening torque
Fixing screws max.0,8 Nm
Ready delay 0,5 s
Switching frequency max.1 Hz
Connection connection cable PUR, length 20m
Bending radius
static 5 x cable diameter
Dynamic 10 x cable diameter
Electrical connection ratings
Operating voltage DC
UB 24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV
Current consumption
No load on outputs max.35 mA
Fusing
External (operating voltage) 0,25 ... 8 A
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In acc. with EN IEC 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Switch-on time
Safety outputs max.300 ms
Safety class III
Risk time according to EN 60947-5-3 max.260 ms
Monitoring output OD
Type of output p-switching, short circuit-proof
Switching current max.50 mA
Output voltage 0,8 x UB ... UB V DC
Safety outputs FO1A / FO1B
Test pulses max.0,3 ms
Test-pulse interval min.100 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Switching current
per safety output 1 ... 150 mA
Output voltage
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
HIGH U(FO1A) / U(FO1B) UB-1,5V ... UB V DC
Utilization category according to EN 60947-5-2
DC-13 24V 150mA
Rated conditional short-circuit current 100 A
Off-state current Ir max.0,25 mA
Discrepancy time max.10 ms
Work area
Repeat accuracy R ? 10
Other
Additional feature Rubber support included
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 4.1 x 10-9
Mission time 20
In combination with Actuator CES-A-BBN-C04-115271Operating distance
Switch-on distance
Approach direction C or D (broad side) 11 mm
Approach direction A or B (front side) 15 mm
Assured operating distance Sao
Approach direction A or B (front side) min.10 mm
Approach direction C or D (broad side) min.6 mm
In combination with Actuator CES-A-BDN-06-104730Operating distance
Switch-on distance
Approach direction C or D (broad side) 15 mm
Approach direction A or B (front side) 19 mm
Assured operating distance Sao
Approach direction A or B (front side) min.14 mm
Approach direction C or D (broad side) min.10 mm
In combination with Actuator CES-A-BDN-06-104730, CES-A-BBN-C04-115271Operating distance
Assured switch-off distance Sar
In y direction max.60 mm
In x/z direction max.40 mm
Switching hysteresis min.1 mm