We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
MGB-L1-APA-AH3A1-S1-L-115896
Part number
115896
Stock availability:
On request
If you are questing Euchner MGB-L1-APA-AH3A1-S1-L-115896 115896, get in touch with FAMAGA, the world's primary vendor of industrial equipment. Our company has functioned for more than ten years - these are cycles of experience, which are illustrated in the quality of outcomes and private attention to each client. We esteem everyone, who joined with us - thus, our regular purchasers procure the most attractive purchase forms and discounts on the factory-made equipment market. Today, there are more than 4 thousand such consumers, and we constantly compose new agreements. More than 600 agreements are achieved per day, because FAMAGA delivers all over the planet Germany, United Kingdom, Moldova, Fiji, Niger, Latvia, Ireland, Netherlands, Panama, Russia, Mongolia, Comoros, Seychelles, Monaco, Switzerland, Slovenia, Uganda, Romania, Canada, United States, Laos, Cyprus, Liechtenstein, Swaziland, Bolivia, Poland, Mexico, Albania, Australia, Macedonia, Djibouti, Brunei, Mauritania, Austria, El Salvador, Czech Republic, Jamaica, Dominica, Belarus, Philippines, Pakistan, Benin, North Korea, Iraq, Tajikistan, Estonia, Kuwait, Lithuania. A well-built logistics system and a partnership network cheer us to deliver our items anywhere in the planet as soon as possible without undermining product quality.
A particular source of pride for FAMAGA is its employees, each of whom contributes to common cause. We request into our team only professionals, who already have experience in the sphere of manufacturing equipment.
All items from FAMAGA are affirmed - we are responsible for the outcome of our work. Now, more than 10 million units of products have been delivered, and this amount is growing every day. We are happy that customers choose FAMAGA again and again, and we are pleased to make more developed and technologically innovative industrial equipment so as stay in control.
To request or place an order, phone us or write a message to the online chat on our site. You can also dispatch a list of the necessary equipment to the email of our company - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
MGB-L1... | The locking arm is held in the locked position by spring force and is unlocked by solenoid force (closed-circuit current principle, mechanically locked). |
OT | Bolt tongue inserted in the evaluation module |
OI | Diagnostics, there is a fault |
S1 | 2 positively driven NC contacts and 1 NO contact (e.g. monitoring contact), emergency stop with turn-to-reset, not illuminated |
H2 | LED, green |
S3 | 1 NO contact, red, illuminated |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 0,75 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN left |
Switching frequency | 0,25 Hz |
Connection | Plug connector RC18 |
Guard locking principle | Closed-circuit current principle |
Locking force FZh | 2000 N |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.375 mA |
Safety outputs FO1A, FO1B | |
Test pulses | max.0,3 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
Controls and indicators | |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Emergency stop | |
Switching voltage | 5 ... 24 V |
Switching current | 1 ... 100 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Solenoid control input IMP1, IMP2, IMM | |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
Belegungsschema | L1 |
Position 1 | |
Ausfuhrung | Emergency stop |
Einlegeschild | |
Extras | With auxiliary contact |
Farbe | |
Schaltelement | 2 pos. driven NC + 1NO |
Position 2 | |
Ausfuhrung | Cover for indicators |
Einlegeschild | |
Extras | |
Farbe | Green |
Schaltelement | |
Position 3 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | |
Farbe | Red |
Schaltelement | 1NO |
Product version number | V3.0.3 |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Control of the guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 2.8 x 10-9 |
Emergency stop | |
B10D | |
Emergency stop | 0,065 x 106 |
Mission time | 20 y |