We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are looking for Euchner CES-AR-CL2-CH-SA-115793 115793, call FAMAGA, the world's primary producer of industrial equipment. Our company has functioned for more than ten years - these are years of experience, which are symbolized in the quality of products and private attention to each client. We cherish everyone, who joined with us - so, our regular clients obtain the most acceptable purchase conditions and discounts on the manufacturing equipment market. Nowadays, there are more than 4500 such consumers, and we constantly form new agreements. More than 750 purchases are terminated per day, because FAMAGA works all over the earth Germany, United Kingdom, Mauritania, Burundi, Burkina Faso, Senegal, Chile, Uzbekistan, Kenya, Antigua and Barbuda, Samoa, Ghana, Kazakhstan, Liechtenstein, Kiribati, Guinea, Costa Rica, Liberia, Malawi, Slovakia, Pakistan, Norway, El Salvador, New Zealand, India, Paraguay, Montenegro, Mali, Dominica, Estonia, Nigeria, Iran, Rwanda, Indonesia, Afghanistan, Tonga, Equatorial Guinea, Kyrgyzstan, Andorra, Moldova, Niger, Panama, Jordan, Tunisia, Laos, Uruguay, Benin. A well-built logistics system and a partnership network assist us to send our goods anywhere in the earth quickly without compromising product quality.
A special source of honor for FAMAGA is its personnel, each of whom contributes to common cause. We request into our team only specialists, who already have experience in the direction of machine made streamlined equipment.
All merchandises from FAMAGA are ensured - we are responsible for the result of our work. At this moment, more than 10 million units of products have been provided, and this quantity is amounting every day. We are glad that users choose FAMAGA again and again, and we strive to make more progressive and technologically advanced industrial equipment so as to stay on the top.
To inquire or order, get in touch with us or write to the online chat on our site. You can also direct a list of the needful equipment to the email of firm - we will contact you ourselves with a made commercial proposal from FAMAGA.
STATE | Status LED |
DIA | Diagnostics LED |
OUT | Monitoring output (semiconductor) |
RST | Reset input |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connection cable |
---|---|---|---|---|
1 | IB | Enable input for channel 2 | WH | |
2 | UB | Power supply, DC 24 V | BN | |
3 | OA | Safety output, channel 1 | GN | |
4 | OB | Safety output, channel 2 | YE | |
5 | OUT | Monitoring output | GY | |
6 | IA | Enable input for channel 1 | PK | |
7 | 0V | Ground, DC 0 V | BU | |
8 | RST | Reset input | RD |
Housing material | Plastic, PBT |
Weight | |
Net | 0,05 kg |
Ambient temperature | |
Cable dynamic | -25 ... 65 °C |
Cable static | -25 ... 65 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting method | Surface mounting on metal |
Mounting distance | |
Between 2 switches or 2 actuators | min.120 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | max.1 Nm |
Ready delay | 10 s |
Switching frequency | max.1 Hz |
Connection | Connection cable PUR, length 15cm with plug connector M12 8-pin |
Bending radius | |
Dynamic | 10 x cable diameter |
static | 5 x cable diameter |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Regulated, residual ripple < 5 % |
Current consumption | max.50 mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In accordance with EN IEC 60947-5-3 and EN IEC 61326-3-1 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.400 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.260 ms |
Safety outputs OA/OB | |
Test pulses | max.1 ms |
Test-pulse interval | min.140 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 200 mA |
Output voltage | |
HIGH U(OA) / U(OB) | UB-1,5V ... UB V DC |
LOW U(OA) / U(OB) | 0 ... 1 V DC |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated conditional short-circuit current | 100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | max.50 mA |
Output voltage | 0,8 x UB ... UB V DC |
Repeat accuracy R | ? 10 |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 1.9 x 10-9 |
Mission time | 20 |
Switch-on distance | 19 mm |
Assured switch-off distance Sar | |
In x/z direction | max.40 mm |
In y direction | max.60 mm |
Assured operating distance Sao | min.14 mm |
Switching hysteresis | min.1 mm |
Switch-on distance | 15 mm |
Assured switch-off distance Sar | |
In x/z direction | max.40 mm |
In y direction | max.60 mm |
Assured operating distance Sao | min.10 mm |
Switching hysteresis | min.1 mm |