We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CET3-AR-CDA-AH-50F-SH-114647
Part number
114647
Stock availability:
On request
If you are pursuing Euchner CET3-AR-CDA-AH-50F-SH-114647 114647, communicate with FAMAGA, the world's influential retailer of machine made equipment. Our company has existed for more than ten years - these are cycles of experience, which are represented in the quality of merchandises and private attention to each purchaser. We value everyone, who cooperated with us - hence, our regular customers bring in the most convenient purchase forms and discounts on the factory-made equipment market. Nowadays, there are more than 4000 such consumers, and we constantly form new agreements. More than 600 agreements are achieved per day, because FAMAGA supplies all over the world Germany, United Kingdom, Cambodia, Bahamas, Sudan, Finland, Algeria, Slovenia, Mauritius, Cape Verde, Poland, Pakistan, Belgium, Thailand, Colombia, Luxembourg, Comoros, Panama, Georgia, Switzerland, East Timor, Iran, South Korea, Zambia, The Gambia, Mexico, Japan, Liechtenstein, Nepal, Malaysia, Croatia, Kazakhstan, Latvia, Cameroon, Zimbabwe, Angola, Russia, Guatemala, Tajikistan, Egypt, Sweden, Syria, Chile, Samoa, Botswana, Brunei, Djibouti, New Zealand. A well-built logistics connection and a partnership network cheer us to dispatch our goods anywhere in the world on-time without compromising product quality.
A particular source of dignity for FAMAGA is its personnel, each of whom contributes to our work. We request into our team only experts, who already have experience in the sphere of manufacturing equipment.
All outcomes from FAMAGA are guaranteed - we are responsible for the cause of our work. At the moment, more than 10 million units of products have been delivered, and this amount is amounting every day. We are proud that consumers choose FAMAGA again and again, and we strive to make more developed and technologically innovative industrial equipment so as keep on top of it.
To consult or book, call us by phone or write a message to the online chat on our site. You can also forward a list of the required equipment to the email of corporation - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
CET3 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active. |
LED State | Status LED |
LED DIA | Diagnostic LED |
LED 1 rd | freely configurable |
LED 2 gn | freely configurable |
OUT | Monitoring output (semiconductor) |
OUT D | Door monitoring output |
RST | Reset input |
J | Teach-in input |
Housing material | |
Slide | Stainless steel |
Safety switch housing | Die-cast aluminum |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65/IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
Y | ±5 mm |
X | ±5 mm |
Z | ±4 mm |
Ready delay | 10 s |
Switching frequency | max.0,5 Hz |
Connection | 1 plug connector M23, 19-pin, RC18 |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N FZH = FMAX/1.3 |
Operating voltage DC | |
UB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
LED | 24 V DC -15% ... 10% |
Current consumption | |
ICM | 480 mA |
IB | 80 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 8 A |
External (solenoid operating voltage UCM) | 0,5 ... 8 A |
Power consumption | |
Solenoid | max.12 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | 30V DC, 2A |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs OA/OB | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output OA / OB | 1 ... 200 mA |
Output voltage | |
Low U(OA) / U(OB) | 0 ... 1 V DC |
High U(OA) / U(OB) | UB-1,5V ... UB V DC |
Off-state current Ir | max.0,25 mA |
Risk time according to EN 60947-5-3 | |
Single device | max.400 ms |
Delay per device | 5 ms |
Switch-on time | 400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT | 1 ... 50 mA |
Output voltage | |
OUT | 0,8xUB ... UB V DC |
Switching delay from state change | max.400 ms |
Monitoring output OUT D | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT D | 1 ... 50 mA |
Output voltage | |
OUT D | 0,8xUB ... UB V DC |
Switching delay from state change | max.700 ms |
Teach-in input | |
Input voltage | |
Low | 0 ... 1 V DC |
High | 15 ... 27,6 V DC |
Repeat accuracy R | 10 % |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Monitoring of guard locking and the safety guard position | |
Category | |
Head downward or horizontal | 4 |
Head upward | 3 |
Performance Level | PL e |
PFHD | |
Head upward | 4.29 x 10-8 |
Head downward or horizontal | 3.1 x 10-9 |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Mission time | 20 y |