We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CET1-AR-CDA-CH-50X-SH-113255
Part number
113255
Stock availability:
On request
If you are questing Euchner CET1-AR-CDA-CH-50X-SH-113255 113255, reach FAMAGA, the world's principle vendor of streamlined equipment. Our company has lasted for more than ten years - these are ages of experience, which are portrayed in the quality of outputs and special attention to each user. We cherish everyone, who worked with us - hence, our regular clients procure the most attractive purchase terms and discounts on the manufacturing equipment market. Nowadays, there are more than 4500 such buyers, and we constantly make new agreements. More than 750 contracts are concluded per day, because FAMAGA supplies all over the earth Germany, United Kingdom, Cambodia, Fiji, Jordan, Montenegro, Tunisia, Netherlands, Czech Republic, Equatorial Guinea, Senegal, Jamaica, Burma, Colombia, Myanmar, Paraguay, Sierra Leone, Brazil, Zambia, Romania, Chile, Chad, Grenada, Sudan, Madagascar, Laos, Bosnia and Herzegovina, Belize, Namibia, Mali, Gambia, Uzbekistan, Samoa, Mongolia, Nigeria, Burundi, New Zealand, China, Uruguay, Panama, Dominica, Cameroon, Bulgaria, Turkey, Croatia, Rwanda, Norway. A well-elaborated logistics series and a partnership network help us to deliver our goods anywhere in the earth promptly without disreputing product quality.
A specific source of pride for FAMAGA is its workers, each of whom contributes to common cause. We invite into our team only professionals, who already have experience in the direction of machine made streamlined equipment.
All outcomes from FAMAGA are ensured - we are responsible for the outcome of our work. Now, more than 10 million units of products have been provided, and this quantity is increasing every day. We are glad that purchasers choose FAMAGA again and again, and we are happy to make more progressive and technologically advanced industrial equipment so as keep on top of it.
To inquire or place an order, phone us or send a message to the online chat on our site. You can also forward a list of the needful equipment to the email of our company - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
CET1 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. |
LED State | Status LED |
LED DIA | Diagnostic LED |
LED 1 rd | freely configurable |
LED 2 gn | freely configurable |
OUT | Monitoring output (semiconductor) |
RST | Reset input |
Housing material | |
Slide | Stainless steel |
Safety switch housing | Die-cast aluminum |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65/IP67 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
Y | ±5 mm |
Z | ±4 mm |
X | ±5 mm |
Ready delay | 10 s |
Switching frequency | max.0,5 Hz |
Connection | 1 plug connector M23, 19-pin, RC18 |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Operating voltage DC | |
LED1 , LED2 | 24 V DC -15% ... 10% |
UB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IB | 80 mA |
ICM | 480 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 8 A |
External (operating voltage UCM) | 0,5 ... 8 A |
Power consumption | |
Solenoid | max.12 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs OA/OB | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
High U(OA,OB) | UB-1,5V ... UB V DC |
Low U(OA,OB) | 0 ... 1 V DC |
Output current | |
per safety output | 1 ... 200 mA |
Off-state current Ir | max.0,25 mA |
Risk time according to EN 60947-5-3 | |
Single device | max.400 ms |
Delay per device | 5 ms |
Switch-on time | |
Safety outputs | 400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms |
Monitoring output OUT | |
Type of output | Semiconductor output, p-switching, short circuit-proof |
Output voltage | |
OUT | 0,8xUB ... UB V DC |
Output current | |
OUT | 1 ... 50 mA |
Repeat accuracy R | 10 % |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Monitoring of guard locking and the safety guard position | |
Category | |
Head upward | 3 |
Head downward or horizontal | 4 |
Performance Level | PL e |
PFHD | |
Head downward or horizontal | 3.1 x 10-9 |
Head upward | 4.29 x 10-8 |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Mission time | 20 y |