We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CET3-AR-CRA-AH-50F-SH-C2353-113023
Part number
113023
Stock availability:
On request
If you are seeking Euchner CET3-AR-CRA-AH-50F-SH-C2353-113023 113023, call FAMAGA, the world's foremost supplier of industrialized equipment. Our company has advanced for more than ten years - these are ages of experience, which are expressed in the quality of items and particular attention to each customer. We value everyone, who engaged with us - so, our regular purchasers bring in the most attractive purchase conditions and discounts on the factory-made equipment market. Nowadays, there are more than 4500 such customers, and we constantly compose new agreements. More than 600 agreements are achieved per day, because FAMAGA supplies all over the planet Germany, United Kingdom, Lebanon, Philippines, Denmark, Uruguay, Tanzania, Russia, Senegal, Cuba, Uganda, Vietnam, Gambia, Japan, Malawi, Thailand, Romania, Czech Republic, Niger, Austria, Liechtenstein, Saudi Arabia, Suriname, Brazil, Fiji, Tonga, Israel, Hungary, Jordan, Antigua and Barbuda, Mauritania, Moldova, Namibia, Andorra, Iraq, Samoa, Sierra Leone, Cape Verde, Belize, Norway, Central African Republic, Bangladesh, Bolivia, Montenegro, Iceland. A advanced logistics system and a partnership network cheer us to ship our products anywhere in the world with no delay without damaging product quality.
A particular source of pride for FAMAGA is its workers, each of whom contributes to common cause. We call into our team only experts, who already have experience in the sphere of industrial equipment.
All products from FAMAGA are affirmed - we are responsible for the aftereffect of our work. Now, more than 10 million units of products have been shipped, and this amount is amounting every day. We are glad that buyers choose FAMAGA again and again, and we are pleased to make more developed and technologically advanced industrial equipment so as keep on top of it.
To consult or place an order, phone us or write a message to the online chat on our site. You can also direct a list of the required equipment to the email of firm - we will contact you ourselves with a made commercial proposal from FAMAGA.
CET3 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active. |
LED State | Status LED |
LED DIA | Diagnostic LED |
LED 1 rd | freely configurable |
LED 2 gn | freely configurable |
OUT | Monitoring output (semiconductor) |
OUT D | Door monitoring output |
RST | Reset input |
J | Teach-in input |
Housing material | |
Slide | Stainless steel |
Safety switch housing | Die-cast aluminum |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65/IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
Z | ±4 mm |
Y | ±5 mm |
X | ±5 mm |
Ready delay | 10 s |
Switching frequency | max.0,5 Hz |
Connection | 1 plug connector M23, 19-pin, RC18 |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N FZH = FMAX/1.3 |
Operating voltage DC | |
UB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
LED | 24 V DC -15% ... 10% |
Current consumption | |
IB | 80 mA |
ICM | 480 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (solenoid operating voltage UCM) | 0,5 ... 8 A |
External (operating voltage UB) | 0,25 ... 8 A |
Power consumption | |
Solenoid | max.12 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | 30V DC, 2A |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs OA/OB | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output OA / OB | 1 ... 200 mA |
Output voltage | |
High U(OA) / U(OB) | UB-1,5V ... UB V DC |
Low U(OA) / U(OB) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Risk time according to EN 60947-5-3 | |
Single device | max.400 ms |
Delay per device | 5 ms |
Switch-on time | 400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT | 1 ... 50 mA |
Output voltage | |
OUT | 0,8xUB ... UB V DC |
Switching delay from state change | max.400 ms |
Monitoring output OUT D | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT D | 1 ... 50 mA |
Output voltage | |
OUT D | 0,8xUB ... UB V DC |
Switching delay from state change | max.700 ms |
Teach-in input | |
Input voltage | |
High | 15 ... 27,6 V DC |
Low | 0 ... 1 V DC |
Repeat accuracy R | 10 % |
C number | |
C2353 | Extended escape release and wire front release (bowden) mounted |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Monitoring of guard locking and the safety guard position | |
Category | |
Head upward | 3 |
Head downward or horizontal | 4 |
Performance Level | PL e |
PFHD | |
Head downward or horizontal | 3.1 x 10-9 |
Head upward | 4.29 x 10-8 |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Mission time | 20 y |