Specifications MGB-L0-ARA-AA1A1-S1-L-111941 111941

If you are questing Euchner MGB-L0-ARA-AA1A1-S1-L-111941 111941, catch up with FAMAGA, the world's foremost distributor of machine made equipment. Our company has functioned for more than ten years - these are ages of experience, which are outlined in the quality of products and particular attention to each purchaser. We esteem everyone, who joined with us - so, our regular purchasers accept the most beneficial purchase terms and discounts on the factory-made equipment market. Now, there are more than 4000 such purchasers, and we constantly form new agreements. More than 600 contracts are concluded per day, because FAMAGA works all over the world . A well-shaped logistics connection and a partnership network help us to deliver our products anywhere in the world quickly without compromising product quality.

A specific source of pride for FAMAGA is its employees, each of whom contributes to our work. We call into our team only specialists, who already have experience in the sphere of manufacturing equipment.

All spare parts from FAMAGA are affirmed - we are responsible for the result of our work. Now, more than 10 million units of products have been delivered, and this amount is growing every day. We are proud that users choose FAMAGA again and again, and we strive to make more developed and technologically innovative industrial equipment so as to stay on the top.

To request or order, phone us or send a message to the online chat on our site. You can also direct a list of the required equipment to the email of firm - we will contact you ourselves with a worked out commercial proposal from FAMAGA.

Features MGB-L0-ARA-AA1A1-S1-L-111941 111941

  • Locking (without guard locking)
  • Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
  • With plug connector RC18
  • Unicode
Door hinge A mechanical door stop is permanently integrated into the evaluation module of the MGB. A marking on the stop makes adjustment easier. LED indicator The LED indicator indicates all important system and status information. Monitoring outputs
OTBolt tongue inserted in the evaluation module
OIDiagnostics, there is a fault
Dimension drawing Dimension drawing Plug connector RC18 MGB: The MGB-System in use MGB: MGB Impact test MGB: Mounting left door, with escape release Mounting left door, without escape release Mounting right door, without escape release MGB: Changing single wiring (AP) to series wiring (AR) MGB: Deactivating guard lock monitor MGB: Activating guard lock monitor MGB: Activating release monitoring MGB: Change color-lens push button Dimension drawingDimension drawingPlug connector RC18 Technical dataApprovals Mechanical values and environment
Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
Weight
Net 0,75 kg
Ambient temperature
At UB = 24V DC -20 ... 55 °C
Degree of protection IP65
Mechanical life 1 x 106
In case of use as door stop, and 1 Joule impact energy 0,1 x 106
Installation orientation Door hinge DIN left
Switching frequency 0,25 Hz
Connection Plug connector RC18
Electrical connection ratings
Utilization category according to EN 60947-5-2
DC-13 24V 200mA
Rated insulation voltage Ui 30 V
Rated impulse withstand voltage Uimp 1,5 kV
Degree of contamination (external, according to EN 60947-1) 3
Safety class III
Discrepancy time
Between FO1A and FO1B max.10 ms
Risk time according to EN 60947-5-3 max.350 ms
Transponder coding Unicode
Power supply UB
Operating voltage DC
UB 24 V DC -15% ... 10%
Current consumption
IUB max.80 mA
Power supply UA
Operating voltage DC
UA 24 V DC -15% ... 10%
Current consumption
IUA max.10 mA
Safety outputs FO1A, FO1B
Test pulses max.1 ms
Test-pulse interval min.100 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Output voltage
UFO1A /UFO1B HIGH UB-2V ... UB V DC
UFO1A /UFO1B LOW 0 ... 1 V DC
Output current
Per safety output FO1A / FO1B 1 ... 200 mA
Monitoring outputs OD, OT, OL, OI
Type of output Semiconductor outputs, p-switching, short circuit-proof
Output voltage UA-2V ... UA V DC
Output current max.50 mA
Other
Product version number V3.0.0
Reliability values according to EN ISO 13849-1
Monitoring of the position of the safety guard
Category 4
Performance Level PL e
PFHD 3.7 x 10-9
Mission time 20 y