We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are questing Euchner CES-AP-C01-CH-SB-111708 111708, make contact with FAMAGA, the world's central provider of manufacturing equipment. Our company has worked for more than ten years - these are cycles of experience, which are outlined in the quality of products and personalseparate attention to each buyer. We praise everyone, who cooperated with us - hence, our regular customers get the most desirable purchase terms and discounts on the manufacturing equipment market. Now, there are more than 4500 such consumers, and we constantly sign new agreements. More than 750 contracts are concluded per day, because FAMAGA supplies all over the globe Germany, United Kingdom, Botswana, Niger, Chile, Serbia, Palestine, The Gambia, Chad, Belarus, Macedonia, Tanzania, Eritrea, United Arab Emirates, Sierra Leone, Central African Republic, Grenada, Guinea, Norway, Burundi, Uruguay, Estonia, Moldova, Equatorial Guinea, Sudan, Zambia, Lithuania, Syria, New Zealand, Eswatini, Iran, Brazil, Djibouti, Jordan, Yemen, Armenia, Comoros, Mongolia, Hungary, Bolivia, Kiribati, South Korea, North Korea, Kazakhstan. A well-elaborated logistics chains and a partnership network help us to deliver our units anywhere in the planet with no delay without compromising product quality.
A specific source of dignity for FAMAGA is its staff members, each of whom contributes to common cause. We accept into our team only specialists, who already have experience in the range of manufacturing equipment.
All items from FAMAGA are guaranteed - we are responsible for the aftereffect of our work. Nowadays, more than 10 million units of products have been delivered, and this quantity is growing every day. We are glad that purchasers choose FAMAGA again and again, and we are eager to make more progressive and technologically advanced industrial equipment so as keep on top of it.
To get some advice or order, get in touch with us or send a message to the online chat on our site. You can also dispatch a list of the necessary equipment to the email of organization - we will contact you ourselves with a made commercial proposal from FAMAGA.
STATE | Status LED |
DIA | Diagnostics LED |
DIA | Diagnostics output (semiconductor) |
RST | Reset input |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connection cable |
---|---|---|---|---|
1 | UB | Power supply, DC 24 V | BN | |
2 | OA | Safety output, channel 1 | GN | |
3 | 0V | Ground, DC 0 V | BU | |
4 | OB | Safety output, channel 2 | YE | |
5 | - | n.c. | GY |
Housing material | Plastic, PBT |
Weight | |
Net | 0,12 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting distance | min.40 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | max.1 Nm |
Ready delay | 0,5 s |
Switching frequency | max.1 Hz |
Connection | M12 plug connector, 5-pin, pin 5 not used |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
No load on outputs | max.50 mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.400 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | max.260 ms |
Safety outputs OA/OB | |
Test pulses | max.0,4 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 400 mA |
Output voltage | |
LOW U(OA) / U(OB) | 0 ... 1 V DC |
HIGH U(OA) / U(OB) | UB-1,5 ... UB V DC |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 400mA |
Rated conditional short-circuit current | max.100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 2.1 x 10-9 |
Mission time | 20 |
Switch-on distance | 18 mm |
Assured switch-off distance Sar | max.45 mm |
Assured operating distance Sao | min.15 mm |
Switching hysteresis | min.1 mm |
Switch-on distance | 22 mm |
Assured switch-off distance Sar | max.58 mm |
Assured operating distance Sao | min.18 mm |
Switching hysteresis | min.1 mm |
Switch-on distance | 19 mm |
Assured switch-off distance Sar | max.45 mm |
Assured operating distance Sao | min.10 mm |
Switching hysteresis | min.1 mm |
Switch-on distance | 27 mm |
Assured switch-off distance Sar | max.75 mm |
Assured operating distance Sao | min.20 mm |
Switching hysteresis | 3 mm |