Manufacturer
Euchner
Country
Germany
Name
CET3-AR-CRA-CH-50F-SG-110907
Part number
110907
Description
Verriegelter berührungsloser Sicherheitsschalter
Stock availability:
On request
If you are pursuing Euchner CET3-AR-CRA-CH-50F-SG-110907 110907, communicate with FAMAGA, the world's top supplier of industrial equipment. Our company has operated for more than ten years - these are years of experience, which are symbolized in the quality of items and particular attention to each buyer. We value everyone, who cooperated with us - hence, our regular customers receive the most attractive purchase terms and discounts on the factory-made equipment market. Now, there are more than 4 thousand such purchasers, and we constantly form new agreements. More than 600 contracts are concluded per day, because FAMAGA supplies all over the planet Germany, United Kingdom, Senegal, Morocco, Sweden, Paraguay, Mongolia, United Arab Emirates, Central African Republic, Italy, Burkina Faso, Guatemala, Denmark, Brazil, Angola, Uzbekistan, Qatar, Burma, Egypt, Luxembourg, Czech Republic, Eritrea, Guyana, Kuwait, North Korea, Latvia, Madagascar, Croatia, The Bahamas, Tunisia, Ireland, Nepal, Israel, Serbia, The Gambia, Mozambique, Iraq, Russia, Mexico, Dominica, Chile, South Korea, Bangladesh, Pakistan, Antigua and Barbuda. A well-built logistics system and a partnership network help us to deliver our products anywhere in the planet with no delay without compromising product quality.
A specific source of dignity for FAMAGA is its personnel, each of whom contributes to common cause. We request into our team only specialists, who already have experience in the direction of manufacturing equipment.
All products from FAMAGA are verified - we are responsible for the aftereffect of our work. Now, more than 10 million units of products have been delivered, and this amount is amounting every day. We are happy that buyers choose FAMAGA again and again, and we are happy to make more progressive and technologically innovative industrial equipment so as to stay on the top.
To get some advice or make a request, phone us or send a message to the online chat on our site. You can also forward a list of the necessary equipment to the email of firm - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
CET3 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active. |
LED State | Status LED |
LED DIA | Diagnostic LED |
LED 1 rd | freely configurable |
LED 2 gn | illuminates when door is closed |
OUT | Monitoring output (semiconductor) |
OUT D | Door monitoring output |
RST | Reset input |
Housing material | |
Safety switch housing | Die-cast aluminum |
Slide | Stainless steel |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
Z | ±4 mm |
Y | ±5 mm |
X | ±5 mm |
Ready delay | 10 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5 and 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Operating voltage DC | |
LED | 24 V DC -15% ... 10% |
UB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
ICM | 480 mA |
IB | 80 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 8 A |
External (solenoid operating voltage UCM) | 0,5 ... 8 A |
Power consumption | |
Solenoid | max.12 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | 30V DC, 2A |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs OA/OB | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output OA / OB | 1 ... 200 mA |
Output voltage | |
Low U(OA) / U(OB) | 0 ... 1 V DC |
High U(OA) / U(OB) | UB-1,5V ... UB V DC |
Off-state current Ir | max.0,25 mA |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.400 ms |
Switch-on time | 400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT | 1 ... 50 mA |
Output voltage | |
OUT | 0,8xUB ... UB V DC |
Switching delay from state change | max.400 ms |
Monitoring output OUT D | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT D | 1 ... 50 mA |
Output voltage | |
OUT D | 0,8xUB ... UB V DC |
Switching delay from state change | max.700 ms |
Repeat accuracy R | 10 % |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Monitoring of guard locking and the safety guard position | |
Category | |
Head upward | 3 |
Head downward or horizontal | 4 |
Performance Level | PL e |
PFHD | |
Head upward | 4.29 x 10-8 |
Head downward or horizontal | 3.1 x 10-9 |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Mission time | 20 y |