We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
MGB-L1-APA-AC6A1-S1-R-110498
Part number
110498
Stock availability:
On request
If you are looking for Euchner MGB-L1-APA-AC6A1-S1-R-110498 110498, get in touch with FAMAGA, the world's principle provider of industrialized equipment. Our company has advanced for more than ten years - these are years of experience, which are portrayed in the quality of goods and special attention to each customer. We respect everyone, who engaged with us - thus, our regular buyers bring in the most flexible purchase terms and discounts on the machine made streamlined equipment market. Nowadays, there are more than 4500 such purchasers, and we constantly compose new agreements. More than 700 agreements are achieved per day, because FAMAGA supplies all over the globe Germany, United Kingdom, Portugal, Belgium, San Marino, South Africa, Latvia, Slovakia, Saudi Arabia, Sudan, Liberia, Gambia, Uruguay, Lebanon, Guatemala, Suriname, Laos, Djibouti, Moldova, Malaysia, Turkmenistan, Eritrea, Bhutan, Central African Republic, Austria, Zimbabwe, Tanzania, Belize, Benin, Guyana, Liechtenstein, Namibia, Macedonia, Samoa, New Zealand, Malta, Mauritius, Kazakhstan, Zambia, Iraq, India, Iceland, El Salvador, Kenya, Syria, Equatorial Guinea, Kiribati, Turkey, Finland. A advanced logistics chains and a partnership network cheer us to send our goods anywhere in the earth promptly without discrediting product quality.
A particular source of repute for FAMAGA is its workers, each of whom contributes to our work. We invite into our team only experts, who already have experience in the range of machine made streamlined equipment.
All items from FAMAGA are assured - we are responsible for the aftereffect of our work. Nowadays, more than 10 million units of products have been provided, and this bulk is rising every day. We are glad that customers choose FAMAGA again and again, and we are pleased to make more exceptional and technologically advanced industrial equipment so as keep on top of it.
To request or make a request, contact us or write a message to the online chat on our site. You can also dispatch a list of the needful equipment to the email of corporation - we will contact you ourselves with a made commercial proposal from FAMAGA.
MGB-L1... | The locking arm is held in the locked position by spring force and is unlocked by solenoid force (closed-circuit current principle, mechanically locked). |
OT | Bolt tongue inserted in the evaluation module |
OI | Diagnostics, there is a fault |
S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated |
S2 | 1 NO contact, illuminated |
S3 | 1 NO contact, illuminated |
S4 | 1 NO contact, not illuminated |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 0,75 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN right |
Switching frequency | 0,25 Hz |
Connection | Plug connector RC18 |
Guard locking principle | Closed-circuit current principle |
Locking force FZh | 2000 N |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.375 mA |
Safety outputs FO1A, FO1B | |
Test pulses | max.0,3 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
Controls and indicators | |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Emergency stop | |
Switching voltage | 5 ... 24 V |
Switching current | 1 ... 100 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Solenoid control input IMP1, IMP2, IMM | |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
Belegungsschema | L1 |
Position 1 | |
Ausfuhrung | Emergency stop |
Einlegeschild | |
Extras | With auxiliary contact |
Farbe | |
Schaltelement | 2 pos. driven NC + 1NO |
Position 2 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | Printed |
Farbe | Green |
Schaltelement | 1NO |
Position 3 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | Printed |
Farbe | white |
Schaltelement | 1NO |
Position 4 | |
Ausfuhrung | Button |
Einlegeschild | |
Extras | Printed |
Farbe | white |
Schaltelement | 1NO |
Product version number | V3.0.3 |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Control of the guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 2.8 x 10-9 |
Emergency stop | |
B10D | |
Emergency stop | 0,065 x 106 |
Mission time | 20 y |