We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CET2-AR-CRA-CH-50X-SH-110206
Part number
110206
Stock availability:
On request
If you are inspecting Euchner CET2-AR-CRA-CH-50X-SH-110206 110206, contact FAMAGA, the world's key provider of manufacturing equipment. Our company has operated for more than ten years - these are ages of experience, which are portrayed in the quality of outputs and individual attention to each consumer. We admire everyone, who collaborated with us - therefore, our regular customers get the most acceptable purchase forms and discounts on the industrial equipment market. At present, there are more than 4500 such clients, and we constantly form new agreements. More than 750 purchases are terminated per day, because FAMAGA operates all over the world Germany, United Kingdom, Guinea, Chad, Dominican Republic, Slovenia, Belgium, Morocco, Paraguay, Ecuador, Bahamas, Burundi, France, Sierra Leone, Liberia, Seychelles, Zimbabwe, Brazil, Finland, Kyrgyzstan, Saudi Arabia, Togo, South Sudan, Monaco, Bosnia and Herzegovina, Iran, Turkmenistan, Nigeria, Tonga, South Korea, Georgia, Israel, Zambia, Mauritania, Iraq, Kenya, Belize, Australia, Niger, Tunisia, Greece, Argentina, Qatar, Mongolia, Jordan, Cameroon, Lithuania, Bangladesh, Egypt. A advanced logistics chains and a partnership network let us to deliver our elements anywhere in the earth promptly without compromising product quality.
A special source of good name for FAMAGA is its workers, each of whom contributes to our work. We propose into our team only professionals, who already have experience in the field of industrial equipment.
All items from FAMAGA are ensured - we are responsible for the outcome of our work. At the moment, more than 10 million units of products have been provided, and this quantity is increasing every day. We are proud that users choose FAMAGA again and again, and we are pleased to make more advanced and technologically developed industrial equipment so as keep on top of it.
To inquire or place an order, call us by phone or write to the online chat on our site. You can also send a list of the required equipment to the email of organization - we will contact you ourselves with a made commercial proposal from FAMAGA.
CET2 | Open-circuit current principle guard locking by solenoid force. Activation of the guard locking by applying voltage to the guard locking solenoid. |
LED State | Status LED |
LED DIA | Diagnostic LED |
LED 1 rd | freely configurable |
LED 2 gn | freely configurable |
OUT | Monitoring output (semiconductor) |
RST | Reset input |
Housing material | |
Slide | Stainless steel |
Safety switch housing | Die-cast aluminum |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65/IP67 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
X | ±5 mm |
Y | ±5 mm |
Z | ±4 mm |
Ready delay | 10 s |
Switching frequency | max.0,5 Hz |
Connection | 1 plug connector M23, 19-pin, RC18 |
Approach speed | 20 m/min |
Guard locking principle | Open-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Operating voltage DC | |
UB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
LED1 , LED2 | 24 V DC -15% ... 10% |
Current consumption | |
IB | 80 mA |
ICM | 480 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 8 A |
External (operating voltage UCM) | 0,5 ... 8 A |
Power consumption | |
Solenoid | max.14 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs OA/OB | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
High U(OA,OB) | UB-1,5V ... UB V DC |
Low U(OA,OB) | 0 ... 1 V DC |
Output current | |
per safety output | 1 ... 200 mA |
Off-state current Ir | max.0,25 mA |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.400 ms |
Switch-on time | |
Safety outputs | 400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms |
Monitoring output OUT | |
Type of output | Semiconductor output, p-switching, short circuit-proof |
Output voltage | |
OUT | 0,8xUB ... UB V DC |
Output current | |
OUT | 1 ... 50 mA |
Repeat accuracy R | 10 % |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Monitoring of guard locking and the safety guard position | |
Category | |
Head downward or horizontal | 4 |
Head upward | 3 |
Performance Level | PL e |
PFHD | |
Head upward | 4.29 x 10-8 |
Head downward or horizontal | 3.1 x 10-9 |
Mission time | 20 y |