We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
MGB-L2-APA-AB6A1-S1-L-110076
Part number
110076
Stock availability:
On request
If you are inspecting Euchner MGB-L2-APA-AB6A1-S1-L-110076 110076, connect FAMAGA, the world's top producer of factory-made equipment. Our company has existed for more than ten years - these are ages of experience, which are represented in the quality of products and individual attention to each buyer. We cherish everyone, who worked with us - therefore, our regular customers obtain the most helpful purchase conditions and discounts on the factory-made equipment market. Now, there are more than 4500 such clients, and we constantly form new agreements. More than 750 contracts are concluded per day, because FAMAGA operates all over the planet Germany, United Kingdom, Chad, Liechtenstein, Singapore, Grenada, East Timor, Bulgaria, Tunisia, Canada, Malta, Colombia, Madagascar, Burma, Israel, United States, Kazakhstan, Turkmenistan, Luxembourg, Georgia, South Sudan, Liberia, Uganda, Burundi, Lithuania, Norway, Mexico, Qatar, Paraguay, Argentina, Mozambique, Azerbaijan, Armenia, Cameroon, Bangladesh, Rwanda, Andorra, Brazil, Chile, Switzerland, Mali, North Korea, Denmark, Moldova, Sierra Leone, Poland. A advanced logistics bond and a partnership network allow us to deliver our products anywhere in the earth as soon as possible without compromising product quality.
A specific source of good name for FAMAGA is its workers, each of whom contributes to common cause. We propose into our team only specialists, who already have experience in the field of manufacturing equipment.
All goods from FAMAGA are ensured - we are responsible for the outcome of our work. Now, more than 10 million units of products have been provided, and this quantity is increasing every day. We are happy that buyers choose FAMAGA again and again, and we are pleased to make more advanced and technologically innovative industrial equipment so as keep on top of it.
To inquire or place an order, phone us or send a message to the online chat on our site. You can also send a list of the necessary equipment to the email of organization - we will contact you ourselves with a made commercial proposal from FAMAGA.
MGB-L2... | The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle, electrically locked). |
OD | ON when the door is closed |
OT | Bolt tongue inserted in the evaluation module |
OI | Diagnostics, there is a fault |
S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, illuminated |
S2 | 1 NO contact, white, illuminated |
S3 | 1 NO contact, white, illuminated |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 0,75 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN left |
Switching frequency | 0,25 Hz |
Connection | Plug connector RC18 |
Guard locking principle | Open-circuit current principle |
Locking force FZh | 2000 N |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Safety outputs FO1A, FO1B | |
Test pulses | max.0,3 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
Controls and indicators | |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Emergency stop | |
Switching voltage | 5 ... 24 V |
Switching current | 1 ... 100 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Solenoid control input IMP1, IMP2, IMM | |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.375 mA |
Belegungsschema | L1 |
Position 1 | |
Ausfuhrung | Emergency stop illuminated |
Einlegeschild | |
Extras | |
Farbe | |
Schaltelement | 2 pos. driven NC |
Position 2 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | Access request |
Extras | |
Farbe | white |
Schaltelement | 1NO |
Position 3 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | Acknowl. Start station |
Extras | |
Farbe | white |
Schaltelement | 1NO |
Product version number | V3.0.3 |
Slide-in label | 2 pcs. without marking |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Emergency stop | |
B10D | |
Emergency stop | 0,065 x 106 |
Mission time | 20 y |