We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are questing Euchner CES-AR-CL2-AH-L05-109047 109047, catch up with FAMAGA, the world's prime producer of manufacturing equipment. Our company has existed for more than ten years - these are years of experience, which are represented in the quality of products and special attention to each user. We cherish everyone, who collaborated with us - so, our regular purchasers obtain the most helpful purchase conditions and discounts on the machine made streamlined equipment market. Nowadays, there are more than 4500 such buyers, and we constantly arrange new agreements. More than 750 purchases are terminated per day, because FAMAGA works all over the globe Germany, United Kingdom, Tonga, Norway, Jamaica, Cameroon, Guinea, Bosnia and Herzegovina, Nigeria, The Gambia, Mongolia, El Salvador, Zimbabwe, Jordan, New Zealand, Indonesia, Algeria, Tanzania, South Korea, Estonia, Bolivia, Andorra, Fiji, Paraguay, Argentina, Mauritius, Finland, Sudan, Montenegro, Dominica, Kenya, Hungary, Iceland, North Korea, Uruguay, Lithuania, Senegal, Iran, United States, Kazakhstan, Laos, Greece, Bulgaria, Kiribati, Sweden. A well-shaped logistics chains and a partnership network assist us to ship our goods anywhere in the earth quickly without damaging product quality.
A particular source of pride for FAMAGA is its staff members, each of whom contributes to our work. We call into our team only professionals, who already have experience in the sphere of factory-made equipment.
All goods from FAMAGA are guaranteed - we are responsible for the result of our work. Nowadays, more than 10 million units of products have been provided, and this quantity is rising every day. We are pleased that clients choose FAMAGA again and again, and we strive to make more developed and technologically modern industrial equipment so as keep on top of it.
To consult or order, contact us or write a message to the online chat on our site. You can also direct a list of the desirable equipment to the email of organization - we will contact you ourselves with a made commercial proposal from FAMAGA.
STATE | Status LED |
DIA | Diagnostics LED |
OUT | Monitoring output (semiconductor) |
RST | Reset input |
Designation | Function | Conductor coloring of connection cable |
---|---|---|
IB | Enable input for channel 2 | WH |
UB | Power supply, DC 24 V | BN |
OA | Safety output, channel 1 | GN |
OB | Safety output, channel 2 | YE |
OUT | Monitoring output | GY |
IA | Enable input for channel 1 | PK |
0V | Ground, DC 0 V | BU |
RST | Reset input | RD |
Housing material | Plastic, PBT |
Weight | |
Net | 0,2 kg |
Ambient temperature | |
Cable static | -30 ... 65 °C |
Cable dynamic | -25 ... 65 °C |
Degree of protection | IP67, IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting method | Surface mounting on metal |
Mounting distance | |
Between 2 switches or 2 actuators | min.120 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | max.1 Nm |
Ready delay | 10 s |
Switching frequency | max.1 Hz |
Connection | connection cable PUR, length 5m |
Bending radius | |
Dynamic | 10 x cable diameter |
static | 5 x cable diameter |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Regulated, residual ripple < 5 % |
Current consumption | max.50 mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.400 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.260 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | max.50 mA |
Output voltage | 0,8 x UB ... UB V DC |
Safety outputs OA/OB | |
Test pulses | max.1 ms |
Test-pulse interval | min.140 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 200 mA |
Output voltage | |
HIGH U(OA) / U(OB) | UB-1,5V ... UB V DC |
LOW U(OA) / U(OB) | 0 ... 1 V DC |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated conditional short-circuit current | 100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 1.9 x 10-9 |
Mission time | 20 |
Switch-on distance | 19 mm |
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Assured operating distance Sao | min.14 mm |
Switching hysteresis | min.1 mm |
Switch-on distance | 15 mm |
Assured switch-off distance Sar | |
In x/z direction | max.40 mm |
In y direction | max.60 mm |
Assured operating distance Sao | min.10 mm |
Switching hysteresis | min.1 mm |