CES-AR-CR2-AH-L05-109046 Euchner 109046
 CES-AR-CR2-AH-L05-109046 Euchner 109046

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

CES-AR-CR2-AH-L05-109046 109046 Euchner

Manufacturer

Euchner

Country

Germany

Name

CES-AR-CR2-AH-L05-109046

Part number

109046

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications CES-AR-CR2-AH-L05-109046 109046

If you are seeking Euchner CES-AR-CR2-AH-L05-109046 109046, get in touch with FAMAGA, the world's key supplier of mechanized equipment. Our company has progressed for more than ten years - these are ages of experience, which are outlined in the quality of outcomes and particular attention to each consumer. We esteem everyone, who engaged with us - thus, our regular buyers receive the most beneficial purchase conditions and discounts on the industrial equipment market. At present, there are more than 4 thousand such purchasers, and we constantly sign new agreements. More than 600 contracts are concluded per day, because FAMAGA delivers all over the world . A well-elaborated logistics network and a partnership network allow us to send our elements anywhere in the planet as soon as possible without discrediting product quality.

A special source of repute for FAMAGA is its personnel, each of whom contributes to our work. We invite into our team only specialists, who already have experience in the range of industrial equipment.

All products from FAMAGA are affirmed - we are responsible for the cause of our work. At the moment, more than 10 million units of products have been delivered, and this amount is amounting every day. We are proud that users choose FAMAGA again and again, and we are glad to make more exceptional and technologically developed industrial equipment so as to stay on the top.

To request or book, call us by phone or write to the online chat on our site. You can also dispatch a list of the required equipment to the email of firm - we will contact you ourselves with a worked out commercial proposal from FAMAGA.

Features CES-AR-CR2-AH-L05-109046 109046

  • Safety switch with integrated evaluation electronics
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Door hinge right
  • Category 4/PL e according to EN ISO 13849-1
  • Connection cable PUR, 5 m, flying lead, 8-core
  • Unicode
  • Two safety screws M4x14 included
Short circuit monitoring The switch generates its own clock signal on the output cables OA/OB. Pay attention to this aspect when connecting to control systems and relays. Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Category according to EN 13849-1 Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated. LED indicator
STATEStatus LED
DIADiagnostics LED
Additional connections
OUTMonitoring output (semiconductor)
RSTReset input
Approach directions Typical operating distance (Actuator CES-A-BLN... in conjunction with safety switch CES-AR-C.2-... in case of mounting on plastic) For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the operating distance of the side lobes is not entered. Attention: The operating distance may vary depending on the background material and installation situation. Terminal assignment
Designation Function Conductor coloring of connection cable
IB Enable input for channel 2 WH
UB Power supply, DC 24 V BN
OA Safety output, channel 1 GN
OB Safety output, channel 2 YE
OUT Monitoring output GY
IA Enable input for channel 1 PK
0V Ground, DC 0 V BU
RST Reset input RD
Housing material Plastic, PBT
Weight
Net 0,2 kg
Ambient temperature
Cable dynamic -25 ... 65 °C
Cable static -30 ... 65 °C
Degree of protection IP67, IP69K
Resilience to vibration In acc. with EN IEC 60947-5-2
Mounting method Surface mounting on metal
Mounting distance
Between 2 switches or 2 actuators min.120 mm
Installation orientation Any
Tightening torque
Fixing screws max.1 Nm
Ready delay 10 s
Switching frequency max.1 Hz
Connection connection cable PUR, length 5m
Bending radius
static 5 x cable diameter
Dynamic 10 x cable diameter
Electrical connection ratings
Operating voltage DC
UB 24 V DC 15% ... 15% Regulated, residual ripple < 5 %
Current consumption max.50 mA
Fusing
External (operating voltage) 0,25 ... 8 A
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In acc. with EN IEC 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Switch-on time
Safety outputs max.400 ms
Safety class III
Risk time according to EN 60947-5-3
Delay per device 5 ms
Single device max.260 ms
Monitoring output OUT
Type of output p-switching, short circuit-proof
Switching current max.50 mA
Output voltage 0,8 x UB ... UB V DC
Safety outputs OA/OB
Test pulses max.1 ms
Test-pulse interval min.140 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Switching current
per safety output 1 ... 200 mA
Output voltage
HIGH U(OA) / U(OB) UB-1,5V ... UB V DC
LOW U(OA) / U(OB) 0 ... 1 V DC
Utilization category according to EN 60947-5-2
DC-13 24V 200mA
Rated conditional short-circuit current 100 A
Off-state current Ir max.0,25 mA
Discrepancy time max.10 ms
Work area
Repeat accuracy R ? 10
Other
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 1.9 x 10-9
Mission time 20
In combination with Actuator CES-A-BLN-R2-100776, CES-A-BLN-U2-103450, CES-A-BLN-L2-104510, CES-A-BLN-U2-112710Operating distance
Switch-on distance 15 mm
Assured switch-off distance Sar
In y direction max.60 mm
In x/z direction max.40 mm
Assured operating distance Sao min.10 mm
Switching hysteresis min.1 mm
In combination with Actuator CES-A-BDN-06-104730Operating distance
Switch-on distance 19 mm
Assured switch-off distance Sar
In y direction max.60 mm
In x/z direction max.40 mm
Assured operating distance Sao min.14 mm
Switching hysteresis min.1 mm