We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are seeking Euchner CES-AR-CL2-CH-SA-105747 105747, communicate with FAMAGA, the world's foremost producer of industrial equipment. Our company has functioned for more than ten years - these are ages of experience, which are depicted in the quality of products and private attention to each purchaser. We cherish everyone, who engaged with us - hence, our regular consumers procure the most helpful purchase terms and discounts on the manufacturing equipment market. Nowadays, there are more than 4 thousand such clients, and we constantly sign new agreements. More than 750 agreements are achieved per day, because FAMAGA works all over the earth Germany, United Kingdom, Mauritania, Mozambique, Moldova, Ireland, Indonesia, Namibia, Yemen, Greece, Botswana, South Sudan, Japan, Poland, Philippines, Bosnia and Herzegovina, Montenegro, Libya, Belarus, Laos, The Bahamas, Belize, Dominica, Iran, The Gambia, Seychelles, Zimbabwe, Brunei, Egypt, Kenya, Nepal, Andorra, Vietnam, Uganda, Croatia, Swaziland, Morocco, Eswatini, Afghanistan, Estonia. A well-elaborated logistics bond and a partnership network cheer us to ship our products anywhere in the world with no delay without disreputing product quality.
A specific source of good name for FAMAGA is its staff members, each of whom contributes to common cause. We request into our team only specialists, who already have experience in the direction of industrial equipment.
All goods from FAMAGA are verified - we are responsible for the result of our work. At this moment, more than 10 million units of products have been shipped, and this quantity is ascending every day. We are happy that buyers choose FAMAGA again and again, and we are eager to make more progressive and technologically innovative industrial equipment so as to stay on the top.
To inquire or place an order, get in touch with us or write a message to the online chat on our site. You can also forward a list of the required equipment to the email of organization - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
STATE | Status LED |
DIA | Diagnostics LED |
OUT | Monitoring output (semiconductor) |
RST | Reset input |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connection cable |
---|---|---|---|---|
1 | IB | Enable input for channel 2 | WH | |
2 | UB | Power supply, DC 24 V | BN | |
3 | OA | Safety output, channel 1 | GN | |
4 | OB | Safety output, channel 2 | YE | |
5 | OUT | Monitoring output | GY | |
6 | IA | Enable input for channel 1 | PK | |
7 | 0V | Ground, DC 0 V | BU | |
8 | RST | Reset input | RD |
Housing material | Plastic, PBT |
Weight | |
Net | 0,09 kg |
Ambient temperature | |
Cable static | -25 ... 65 °C |
Cable dynamic | -25 ... 65 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting method | Surface mounting on metal |
Mounting distance | |
Between 2 switches or 2 actuators | min.120 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | max.1 Nm |
Ready delay | 10 s |
Switching frequency | max.1 Hz |
Connection | Connection cable PUR, length 1m with plug connector M12 8-pin |
Bending radius | |
Dynamic | 10 x cable diameter |
static | 5 x cable diameter |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Regulated, residual ripple < 5 % |
Current consumption | max.50 mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.400 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.260 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | max.50 mA |
Output voltage | 0,8 x UB ... UB V DC |
Safety outputs OA/OB | |
Test pulses | max.1 ms |
Test-pulse interval | min.140 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 200 mA |
Output voltage | |
HIGH U(OA) / U(OB) | UB-1,5V ... UB V DC |
LOW U(OA) / U(OB) | 0 ... 1 V DC |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated conditional short-circuit current | 100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 1.9 x 10-9 |
Mission time | 20 |
Switch-on distance | 19 mm |
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Assured operating distance Sao | min.14 mm |
Switching hysteresis | min.1 mm |
Switch-on distance | 15 mm |
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Assured operating distance Sao | min.10 mm |
Switching hysteresis | min.1 mm |