We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are seeking Euchner TZ1RE110MVAB-C1623 088063, communicate with FAMAGA, the world's major supplier of industrial equipment. Our company has lasted for more than ten years - these are ages of experience, which are depicted in the quality of merchandises and personalseparate attention to each customer. We understand everyone, who cooperated with us - hence, our regular purchasers receive the most convenient purchase terms and discounts on the machine made streamlined equipment market. At this moment, there are more than 4000 such customers, and we constantly arrange new agreements. More than 650 transactions are made per day, because FAMAGA supplies all over the globe Germany, United Kingdom, Botswana, Nepal, Senegal, Papua New Guinea, Haiti, Albania, Azerbaijan, Honduras, Malaysia, Malawi, Switzerland, Monaco, Costa Rica, Cameroon, Sweden, Netherlands, Lithuania, Guyana, Indonesia, Afghanistan, Ireland, Georgia, Hungary, Tonga, Brunei, Iran, Vietnam, Seychelles, Benin, China, Jordan, Mexico, Antigua and Barbuda, Uganda, Cyprus, Dominica, Zimbabwe, Laos, Mauritius, Poland. A well-developed logistics system and a partnership network help us to ship our goods anywhere in the world with no delay without damaging product quality.
A special source of pride for FAMAGA is its employees, each of whom contributes to our work. We accept into our team only professionals, who already have experience in the direction of factory-made equipment.
All products from FAMAGA are guaranteed - we are responsible for the aftereffect of our work. Nowadays, more than 10 million units of products have been shipped, and this number is growing every day. We are pleased that customers choose FAMAGA again and again, and we strive to make more progressive and technologically modern industrial equipment so as not to lower the bar.
To consult or make a request, contact us or write to the online chat on our official website. You can also forward a list of the desirable equipment to the email of our company - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
TZ1 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid. |
SK | For monitoring the door/actuator position |
UK | For monitoring the guard locking (built-in solenoid) |
2131H | Slow-action switching contact 3 NC + 1 NO |
3131H | Slow-action switching contact 2 NC + 2 NO |
Housing material | Anodized die-cast alloy |
Weight | |
Net | 1,2 kg |
Ambient temperature | -25 ... 80 °C |
Degree of protection | IP67 |
Mechanical life | 1 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Slow-action switching contact |
Installation orientation | Any |
Number of door position positively driven contacts | 3 |
Number of door position NO contacts | 1 |
Number of guard lock monitoring positively driven contacts | 2 |
Number of guard lock monitoring NO contacts | 2 |
Connection | |
1 x | M20 x 1.5 |
Approach speed | max.20 m/min |
Actuation frequency | 1200 1/h |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 2000 N |
Locking force FZh | 1500 N |
Retention force | 10 N |
Extraction force | 30 N |
Actuating force | 35 N |
Insertion depth | min.52 mm |
Cover lid | Black |
Thermal rated current Ith | 4 A 70°C => 2A'> |
Utilization category according to EN 60947-5-1 | |
AC-15 | 4A 230V 70°C => 2A'> |
DC-13 | 4A 24V 70°C => 2A'> |
Solenoid operating voltage | |
AC | 110 V -15% ... +10% |
Short circuit protection according to IEC 60269-1 | |
(Fuse) | 4A gG 70°C => 2A gG'> |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2,5 kV |
Switching voltage | |
Min. at 10mA | 12 V |
Switching current | |
Min. at 24V | 1 mA |
Power consumption | 10 W |
Solenoid duty cycle | 100 % |
Connection cross-section | 0,34 ... 1,5 mm? |
LED indicator | Operating voltage corresponds to the solenoid voltage |
C number | |
C1623 | Without mechanical release with protective plate |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Monitoring of guard locking and the safety guard position | |
B10D | 3 x 106 |
Overtravel | 4 mm |