We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are looking for Euchner TZ1LE110MVAB 088023, catch up with FAMAGA, the world's the best supplier of industrial equipment. Our company has lasted for more than ten years - these are years of experience, which are illustrated in the quality of spare parts and particular attention to each buyer. We respect everyone, who cooperated with us - so, our regular consumers receive the most flexible purchase terms and discounts on the industrial equipment market. At this moment, there are more than 3500 such purchasers, and we constantly make new agreements. More than 700 transactions are made per day, because FAMAGA works all over the world Germany, United Kingdom, Kyrgyzstan, Sierra Leone, Portugal, Mauritius, Lesotho, Slovenia, Chile, Qatar, Turkmenistan, India, El Salvador, Zambia, Tunisia, Bhutan, Togo, Grenada, Honduras, Jordan, Burkina Faso, Malta, Singapore, Bangladesh, Uruguay, Paraguay, Liberia, Kenya, Indonesia, Cape Verde, Sudan, Zimbabwe, Laos, Ecuador, Iran, Czech Republic, Namibia, Vietnam, New Zealand, Switzerland, Antigua and Barbuda, Nigeria, Georgia, Denmark, Mauritania, Tonga, Turkey. A well-shaped logistics system and a partnership network help us to dispatch our goods anywhere in the globe with no delay without disreputing product quality.
A special source of repute for FAMAGA is its personnel, each of whom contributes to our work. We call into our team only professionals, who already have experience in the sphere of industrial equipment.
All products from FAMAGA are affirmed - we are responsible for the result of our work. At the moment, more than 10 million units of products have been supplied, and this bulk is amounting every day. We are proud that customers choose FAMAGA again and again, and we are glad to make more developed and technologically developed industrial equipment so as stay in control.
To request or order, call us by phone or write to the online chat on our official website. You can also direct a list of the required equipment to the email of corporation - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
TZ1 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid. |
SK | For monitoring the door/actuator position |
UK | For monitoring the guard locking (built-in solenoid) |
2131H | Slow-action switching contact 3 NC + 1 NO |
3131H | Slow-action switching contact 2 NC + 2 NO |
Housing material | Anodized die-cast alloy |
Weight | |
Net | 1,2 kg |
Ambient temperature | -25 ... 80 °C |
Degree of protection | IP67 |
Mechanical life | 1 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Slow-action switching contact |
Installation orientation | Any |
Number of door position positively driven contacts | 3 |
Number of door position NO contacts | 1 |
Number of guard lock monitoring positively driven contacts | 2 |
Number of guard lock monitoring NO contacts | 2 |
Connection | |
1 x | M20 x 1.5 |
Approach speed | max.20 m/min |
Actuation frequency | 1200 1/h |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 2000 N |
Locking force FZh | 1500 N |
Retention force | 10 N |
Extraction force | 30 N |
Actuating force | 35 N |
Insertion depth | min.52 mm |
Cover lid | Black |
Thermal rated current Ith | 4 A 70°C => 2A'> |
Utilization category according to EN 60947-5-1 | |
AC-15 | 4A 230V 70°C => 2A'> |
DC-13 | 4A 24V 70°C => 2A'> |
Solenoid operating voltage | |
AC | 110 V -15% ... +10% |
Short circuit protection according to IEC 60269-1 | |
(Fuse) | 4A gG 70°C => 2A gG'> |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2,5 kV |
Switching voltage | |
Min. at 10mA | 12 V |
Switching current | |
Min. at 24V | 1 mA |
Power consumption | 10 W |
Solenoid duty cycle | 100 % |
Connection cross-section | 0,34 ... 1,5 mm? |
LED indicator | Operating voltage corresponds to the solenoid voltage |
Monitoring of guard locking and the safety guard position | |
B10D | 3 x 106 |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Overtravel | 4 mm |
Overtravel | 16 mm |