Specifications ESM-BA302 087412

If you are looking for Euchner ESM-BA302 087412, contact FAMAGA, the world's chief provider of streamlined equipment. Our company has advanced for more than ten years - these are cycles of experience, which are represented in the quality of spare parts and private attention to each customer. We appreciate everyone, who liased with us - thus, our regular consumers bring in the most favorable purchase terms and discounts on the machine made streamlined equipment market. Now, there are more than 3500 such consumers, and we constantly sign new agreements. More than 700 contracts are concluded per day, because FAMAGA delivers all over the world . A well-elaborated logistics chains and a partnership network help us to ship our units anywhere in the earth on-time without disreputing product quality.

A particular source of dignity for FAMAGA is its staff members, each of whom contributes to our work. We request into our team only experts, who already have experience in the field of machine made streamlined equipment.

All items from FAMAGA are verified - we are responsible for the cause of our work. At the moment, more than 10 million units of products have been provided, and this bulk is ascending every day. We are pleased that purchasers choose FAMAGA again and again, and we are eager to make more exceptional and technologically innovative industrial equipment so as stay in control.

To get some advice or make a request, contact us or send a message to the online chat on our official website. You can also send a list of the needful equipment to the email of corporation - we will contact you ourselves with a worked out commercial proposal from FAMAGA.

Features ESM-BA302 087412

  • ESM-BA.. Usage up to category 4 according to EN ISO 13849-1
  • LED status indicators
  • 1-channel or 2-channel control
  • 3 redundant safety contacts
  • 1 auxiliary contact (monitoring contact)
  • Short circuit and earth fault/ground fault monitoring
Relay outputsThe outputs are electrically decoupled and of redundant design. Connection optionsBy using suitable wiring the following functions can be selected:
  • Relay start with automatic start or a start button.
  • Monitoring of downstream relays or contactors
  • Simultaneity monitoring to monitor safety components over time.
  • Relay start using a monitored start button.
  • Short circuit monitoring to detect short circuits between the connection cables and to shut down the outputs or prevent relay starting if necessary.
  • Earth fault/ground fault monitoring to detect short circuits between the connection cables and earth or ground and to shut down the outputs or prevent relay starting if necessary.
Auxiliary contactsThe relays in the series ESM-BA3.. are available with electrically separate normally closed contacts and auxiliary contacts. Dimension drawing Wiring diagram Dimension drawingWiring diagram Technical dataApprovals Mechanical values and environment
Housing material Polyamide PA6.6
Weight
Net 0,23 kg
Ambient temperature -15 ... 40 °C
Degree of protection IP20
Mechanical life
operating cycles 10 x 106
Contact material AgSnO2
Mounting method Mounting rail 35mm according to DIN EN 60715 TH35
Connection Connection terminals
Length of control cable
With conductor cross-section 0.75mm2 1000 m
Safety contacts 13/14, 23/24, 33/34
Number of safety contacts 3
Auxiliary contacts 41/42
Number of safety contacts 1
Electrical connection ratings
Operating voltage
AC 115 V -10% ... +10%
Power consumption (apparent power)
At 230 V AC 6,9 VA
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp
Leakage path/air gaps 4 kV
Overvoltage category according to IEC EN 60664-1 3
Rated supply frequency 50 ... 60 Hz
Degree of contamination (external, according to EN 60947-1) 2
Connection cross-section 0,14 ... 2,5 mm? Connection terminal (size)
Test voltage
Control system/contacts 2,5 kV
Control voltage
On S11 24 V 18,6 ... 26 V Start button
Control current
S11...S14 60 mA
LED indicator 2 status displays (green) for relays K1 and K2
Safety contacts 13/14, 23/24, 33/34
Type of output
NO Relay contacts, floating and positively driven (redundant)
Switching voltage
AC max.250 V
DC max.24 V
Switching current min.5 mA at 24V
Cumulative current max.15 A For all contacts
Fusing
External contact fuses (safety circuit) according to IEC 60269-1 10A gG (T6A / F8A)
Utilization category according to EN 60947-5-1
AC-15 3A, 250V
DC-13 3A, 24V
AC-12 8A ohmic load, 250V
DC-12 8A ohmic load, 50V
Breaking capacity according to UL 8A 250V AC / 3A 24V DC per contact
Auxiliary contacts 41/42
Type of output
NC Relay contacts, floating
Utilization category according to EN 60947-5-1
AC-12 2A, 250V
DC-12 2A, 50V
Breaking capacity (VA) max.500 VA
Breaking capacity according to UL 2A 250V AC / 2A 24V DC per contact
Other
In compliance with EN 60439-1: 1999 + A1: 2004, EN 60947-1: 2007, EN 60947-5-1: 2004, EN 60947-7-1: 2002, EN 61000-6-2: 2005, EN 61000-6-3: 2007, EN ISO 13849-1: 2015, EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015, EN 60204-1: 2007
Reliability values according to EN ISO 13849-1
Performance Level PL e
Category 4
PFHD 1.2 x 10-8
Number of switching cycles
? 0.1 A at 24 V DC max.500000 1/Jahr
? 1 A at 24 V DC max.350000 1/Jahr
? 2 A at 24 V DC max.100000 1/Jahr
Mission time 20 y