ESM-TE303 Euchner 085619
 ESM-TE303 Euchner 085619

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

ESM-TE303 085619 Euchner

Manufacturer

Euchner

Country

Germany

Name

ESM-TE303

Part number

085619

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications ESM-TE303 085619

If you are looking for Euchner ESM-TE303 085619, catch up with FAMAGA, the world's chief vendor of factory-made equipment. Our company has advanced for more than ten years - these are years of experience, which are outlined in the quality of spare parts and personalseparate attention to each customer. We esteem everyone, who liased with us - thus, our regular customers bring in the most beneficial purchase terms and discounts on the machine made streamlined equipment market. Nowadays, there are more than 4000 such clients, and we constantly sign new agreements. More than 700 agreements are achieved per day, because FAMAGA operates all over the planet . A well-elaborated logistics connection and a partnership network cheer us to ship our elements anywhere in the planet as soon as possible without compromising product quality.

A particular source of good name for FAMAGA is its staff members, each of whom contributes to our work. We accept into our team only experts, who already have experience in the sphere of manufacturing equipment.

All spare parts from FAMAGA are guaranteed - we are responsible for the outcome of our work. Now, more than 10 million units of products have been delivered, and this bulk is growing every day. We are proud that users choose FAMAGA again and again, and we are eager to make more exceptional and technologically innovative industrial equipment so as not to lower the bar.

To inquire or order, contact us or write a message to the online chat on our official website. You can also direct a list of the necessary equipment to the email of corporation - we will contact you ourselves with a worked out commercial proposal from FAMAGA.

Features ESM-TE303 085619

  • Usage up to category 3 according to EN ISO 13849-1
  • LED status indicators
  • Control using safety relays
  • 3 redundant time-delayed safety contacts
  • Delay time-range 1 s - 30 s
  • 1 auxiliary contact
  • Earth fault/ground fault monitoring can be selected
Relay outputsThe outputs are electrically decoupled and of redundant design. ConnectionBy using suitable wiring the following function can be selected:
  • Earth fault/ground fault monitoring to detect short circuits between the connection cables and earth or ground and to shut down the outputs or prevent relay starting if necessary.
Time-delayed shutdownThe release time for the time-delay contacts can be set as required using a potentiometer on the safety relay. Dimension drawing Wiring diagram Dimension drawingWiring diagram Technical dataApprovals Mechanical values and environment
Housing material Polyamide PA6.6
Weight
Net 0,23 kg
Ambient temperature
At UB = 115/230V AC -15 ... 40 °C
Degree of protection IP20
Mechanical life
operating cycles 10 x 106
Contact material AgNi-10
Mounting method Mounting rail 35mm according to DIN EN 60715 TH35
Connection Connection terminals
Length of control cable
With conductor cross-section 0.75mm2 1000 m
Safety contacts 17/18, 27/28, 37/38
Number of safety contacts 3
Auxiliary contact S25/S26
Number of auxiliary contacts 1
Electrical connection ratings
Operating voltage
AC 230 V -10% ... +10%
Power consumption (apparent power)
At 230 V AC 4 VA
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp
Leakage path/air gaps 4 kV
Overvoltage category according to IEC EN 60664-1 3
Rated supply frequency 50 ... 60 Hz
Degree of contamination (external, according to EN 60947-1) 2
Connection cross-section 0,14 ... 2,5 mm? Connection terminal (size)
Test voltage
Control system/contacts 2,5 kV
Control voltage
On S11 24 V
Control current
S11...S14 40 mA
LED indicator 2 status displays (green) for relays K1 and K2
Safety contacts 17/18, 27/28, 37/38
Type of output
NO Relay contacts, floating, positively driven (redundant)
Switching voltage
AC max.250 V
DC max.24 V
Switching current min.20 mA at 24V
Cumulative current max.10,5 A For all contacts
Fusing
External contact fuses (safety circuit) according to IEC 60269-1 10A gG (T4A / F6A)
Utilization category according to EN 60947-5-1
AC-15 4A, 250V
DC-13 2A, 24V
AC-12 6A ohmic load, 250V
DC-12 1.25A ohmic load, 24V
Breaking capacity according to UL 6A 250V AC / 2A 24V DC per contact
Switching characteristics Safety contact with adjustable time-delay
Delay time
Continuously adjustable 1 ... 30 s
Auxiliary contact S25/S26
Type of output
NC As monitoring contact for safety relay
Switching characteristics Auxiliary contact with adjustable time-delay
Other
In compliance with EN 60439-1: 1999 + A1: 2004, EN 60947-1: 2007, EN 60947-5-1: 2004, EN 60947-7-1: 2002, EN 61000-6-2: 2005, EN 61000-6-3: 2007, EN ISO 13849-1: 2015, EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015, EN 60204-1: 2007
Reliability values according to EN ISO 13849-1
Performance Level PL d
Category 3
PFHD 1.03 x 10-7
Number of switching cycles
? 0.1 A at 24 V DC max.400000 1/Jahr
? 1 A at 24 V DC max.73000 1/Jahr
? 2 A at 24 V DC max.17000 1/Jahr
Mission time 20 y