Specifications CMS-E-BR 085537

If you are questing Euchner CMS-E-BR 085537, call FAMAGA, the world's dominant distributor of streamlined equipment. Our company has existed for more than ten years - these are cycles of experience, which are outlined in the quality of products and individual attention to each client. We value everyone, who worked with us - hence, our regular clients receive the most attractive purchase terms and discounts on the manufacturing equipment market. At present, there are more than 3500 such buyers, and we constantly make new agreements. More than 750 purchases are terminated per day, because FAMAGA delivers all over the planet . A well-built logistics series and a partnership network assist us to dispatch our goods anywhere in the planet quickly without undermining product quality.

A special source of honor for FAMAGA is its team members, each of whom contributes to common cause. We propose into our team only professionals, who already have experience in the sphere of manufacturing equipment.

All outputs from FAMAGA are ensured - we are responsible for the cause of our work. Now, more than 10 million units of products have been delivered, and this quantity is increasing every day. We are pleased that clients choose FAMAGA again and again, and we are happy to make more progressive and technologically advanced industrial equipment so as stay in control.

To ask a question or order, get in touch with us or write to the online chat on our official website. You can also direct a list of the necessary equipment to the email of organization - we will contact you ourselves with a made commercial proposal from FAMAGA.

Features CMS-E-BR 085537

  • Four read heads can be connected
  • 1 safety contact
  • 1 auxiliary contact
  • 1 feedback loop can be connected
Functional The evaluation unit CMS-E-BR is suitable for the direct connection of up to 4 read heads. Category/PL according to EN ISO 13849-1
  • Category 3/PL d with more than one read head connected
  • Category 4/PL e with only one read head connected
Notice:At low approach speeds in the z direction, the time offset when switching the reed contacts must not be more than 150 ms. Dimension drawing Wiring diagram CMS: Magnetically coded safety switches Dimension drawingWiring diagram Technical dataApprovals Mechanical values and environment
Housing material Polycarbonate (PC)
Weight
Net 0,24 kg
Ambient temperature 0 ... 50 °C
Degree of protection Terminals IP20 / housing IP40
Mechanical life 30 x 106
Mounting method Mounting rail 35mm according to DIN EN 60715 TH35
Number of read heads Up to 4 read heads
Connection Connection terminals, plug-in
Safety contacts 13/14
Number of safety contacts 1
Auxiliary contacts 23/24
Number of auxiliary contacts 1
Electrical connection ratings
Operating voltage
AC/DC 24 V -10% ... +10%
Fusing
Protection internal (operating voltage UB) 0,5 A Automatically resetting fuse PTC
Rated insulation voltage Ui
AC 250 V
Degree of contamination (external, according to EN 60947-1) 2
Connection cross-section 0,14 ... 2,5 mm?
LED indicator 1 indicator LED Power (UB) green 1 LED safety output (OUT green/red) 8 LED status indicators (Dx1 / Dx2 /green/ red)
Safety contacts 13/14
Type of output Relay contacts, floating
Current consumption 250 mA
Switching voltage
AC max.250 V
Switching current
at DC 24V 13 ... 3000 mA
Fusing
External contact fuse (safety circuit) acc. to EN IEC 60269-1 3A gG
Utilization category according to EN 60947-4-1
Utilization category according to EN 60947-5-1
AC-15 1A , 250V , 1A 24V
DC-13 3A , 24V
Switching load
Switching load acc. to UL Class 2 Input: 24V AC/DC : Output: 30V AC , 24V DC
Breaking capacity (VA) max.750 VA
Risk time according to EN 60947-5-3 20 ms
Auxiliary contacts 23/24
Type of output Relay contact, floating
Other
In compliance with EN ISO 13849-1: 2015, EN 50178: 1997, EN ISO 14119: 2013, EN 6100-6-3: 2007, EN 60947-5-2: 2007/A1: 2012, EN 60947-5-3: 2013
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category
With one read head 4
With more than one read head 3
Performance Level
With one read head PL e
With more than one read head PL d
PFHD
With one read head 2.5 x 10-8
With more than one read head 1.0 x 10-7
Number of switching cycles
? 0.1A at 24V DC max.100000 1/Jahr
? 1A at 24V DC max.18500 1/Jahr
? 3A at 24V DC max.9000 1/Jahr
Mission time 20 y
In combination with Read head CMS-R-AXH-03V, CMS-R-AXH-SC and Actuator CMS-M-ACOperating distance
Center offset
At s=3 mm read distance 2,5 mm
Assured switch-off distance Sar max.31 mm
Assured operating distance Sao
With center offset m=0 min.6 mm
In combination with Read head CMS-R-BXI-03V, CMS-R-BXI-05V, CMS-R-BXI-SC, CMS-R-BXI-07P and Actuator CMS-M-BDOperating distance
Center offset
At s=3 mm read distance 2,5 mm
Assured switch-off distance Sar max.12 mm
Assured operating distance Sao
With center offset m=0 min.3 mm
In combination with Read head CMS-R-CXC-03V, CMS-R-CXC-05V, CMS-R-CXC-05P, CMS-R-CXC-SC and Actuator CMS-M-CAOperating distance
Center offset
At s=3 mm read distance 2,5 mm
Assured switch-off distance Sar max.14 mm
Assured operating distance Sao
With center offset m=0 min.6 mm
In combination with Read head CMS-R-EXM-03V, CMS-R-EXM-05V, CMS-R-EXM-SC and Actuator CMS-M-EFOperating distance
Center offset
At s=3 mm read distance 2,5 mm
Assured switch-off distance Sar max.17 mm
Assured operating distance Sao
With center offset m=0 min.6 mm