TZ2LE110M Euchner 083162
 TZ2LE110M Euchner 083162

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

TZ2LE110M 083162 Euchner

Manufacturer

Euchner

Country

Germany

Name

TZ2LE110M

Part number

083162

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications TZ2LE110M 083162

If you are seeking Euchner TZ2LE110M 083162, get in touch with FAMAGA, the world's key distributor of mechanized equipment. Our company has progressed for more than ten years - these are years of experience, which are described in the quality of items and personalseparate attention to each user. We respect everyone, who worked with us - so, our regular customers accept the most flexible purchase terms and discounts on the factory-made equipment market. Now, there are more than 4000 such clients, and we constantly arrange new agreements. More than 600 contracts are concluded per day, because FAMAGA operates all over the globe . A well-shaped logistics series and a partnership network help us to deliver our goods anywhere in the globe immediately without compromising product quality.

A special source of good name for FAMAGA is its personnel, each of whom contributes to common cause. We accept into our team only professionals, who already have experience in the range of factory-made equipment.

All outputs from FAMAGA are guaranteed - we are responsible for the outcome of our work. Nowadays, more than 10 million units of products have been supplied, and this amount is growing every day. We are proud that customers choose FAMAGA again and again, and we are glad to make more developed and technologically advanced industrial equipment so as not to lower the bar.

To inquire or book, phone us or send a message to the online chat on our official website. You can also dispatch a list of the desirable equipment to the email of firm - we will contact you ourselves with a made commercial proposal from FAMAGA.

Features TZ2LE110M 083162

  • Auxiliary release on the front
  • Two LED indicators, red and green
  • Actuating head fitted left
Approach direction Horizontal Can be adjusted in 90° steps Solenoid operating voltage and LED function display
  • 110 V AC -15%, +10%
Guard locking type
TZ2Open-circuit current principle, guard locking by applying voltage to the solenoid. Release by spring force.
Switching element
SKFor monitoring the door/actuator position
UKFor monitoring the guard locking (built-in solenoid)
528HSlow-action switching contact 1 NC + 1 NO
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. Sealing can be fitted to protect against tampering. Lead seal kit and tool included (already pre-assembled on versions with plug connectors).
Housing material Anodized die-cast alloy
Weight
Net 1,2 kg
Ambient temperature -25 ... 80 °C
Degree of protection IP67
Mechanical life 1 x 106
Contact material Silver alloy, gold flashed
Switching principle Slow-action switching contact
Installation orientation Any
Number of door position positively driven contacts 1
Number of door position NO contacts 1
Number of guard lock monitoring positively driven contacts 1
Number of guard lock monitoring NO contacts 1
Connection
1 x M20 x 1.5
Approach speed max.20 m/min
Actuation frequency 1200 1/h
Guard locking principle Open-circuit current principle
Locking force Fmax 2000 N
Locking force FZh 1500 N
Retention force 10 N
Extraction force 30 N
Actuating force 35 N
Insertion depth min.52 mm
Cover lid Black
Electrical connection ratings
Thermal rated current Ith 4 A 70°C => 2A'>
Utilization category according to EN 60947-5-1
AC-15 4A 230V 70°C => 2A'>
DC-13 4A 24V 70°C => 2A'>
Solenoid operating voltage
AC 110 V -15% ... +10%
Short circuit protection according to IEC 60269-1
(Fuse) 4A gG 70°C => 2A gG'>
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2,5 kV
Switching voltage
Min. at 10mA 12 V
Switching current
Min. at 24V 1 mA
Power consumption 10 W
Solenoid duty cycle 100 %
Connection cross-section 0,34 ... 1,5 mm?
LED indicator Operating voltage corresponds to the solenoid voltage
Reliability values according to EN ISO 13849-1
Monitoring of guard locking and the safety guard position
B10D 3 x 106
In combination with Actuator BETAETIGER-Z-GMechanical values and environment
Overtravel 4 mm
In combination with Actuator BETAETIGER-Z-GNMechanical values and environment
Overtravel 16 mm