TZ1RE024SR6 Euchner 046190
 TZ1RE024SR6 Euchner 046190

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

TZ1RE024SR6 046190 Euchner

Manufacturer

Euchner

Country

Germany

Name

TZ1RE024SR6

Part number

046190

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications TZ1RE024SR6 046190

If you are questing Euchner TZ1RE024SR6 046190, catch up with FAMAGA, the world's chief vendor of manufacturing equipment. Our company has operated for more than ten years - these are cycles of experience, which are illustrated in the quality of products and particular attention to each customer. We respect everyone, who collaborated with us - so, our regular customers procure the most favorable purchase terms and discounts on the factory-made equipment market. Today, there are more than 4000 such purchasers, and we constantly form new agreements. More than 700 proceedings are resolved per day, because FAMAGA works all over the planet . A well-developed logistics chains and a partnership network help us to deliver our items anywhere in the world with no delay without compromising product quality.

A specific source of repute for FAMAGA is its personnel, each of whom contributes to common cause. We accept into our team only experts, who already have experience in the sphere of manufacturing equipment.

All spare parts from FAMAGA are affirmed - we are responsible for the result of our work. Now, more than 10 million units of products have been supplied, and this number is amounting every day. We are happy that consumers choose FAMAGA again and again, and we are glad to make more developed and technologically innovative industrial equipment so as stay in control.

To request or order, phone us or send a message to the online chat on our official website. You can also direct a list of the necessary equipment to the email of corporation - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.

Features TZ1RE024SR6 046190

  • Auxiliary release on the front
  • Two LED indicators, red and green
  • Plug connector SR6
  • Actuating head fitted right
Approach direction Horizontal Can be adjusted in 90° steps Solenoid operating voltage and LED function display
  • 24 V AC/DC -15%, +10%
Guard locking type
TZ1Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid.
Switching element
SKFor monitoring the door/actuator position
UKFor monitoring the guard locking (built-in solenoid)
528HSlow-action switching contact 1 NC + 1 NO
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. Sealing can be fitted to protect against tampering. Lead seal kit and tool included (already pre-assembled on versions with plug connectors).
Housing material Anodized die-cast alloy
Weight
Net 1,2 kg
Ambient temperature -25 ... 80 °C
Degree of protection IP65
Mechanical life 1 x 106
Contact material Silver alloy, gold flashed
Switching principle Slow-action switching contact
Installation orientation Any
Number of door position positively driven contacts 1
Number of door position NO contacts 1
Number of guard lock monitoring positively driven contacts 1
Number of guard lock monitoring NO contacts 1
Connection
1 x Plug connector SR6
Approach speed max.20 m/min
Actuation frequency 1200 1/h
Guard locking principle Closed-circuit current principle
Locking force Fmax 2000 N
Locking force FZh 1500 N
Retention force 10 N
Extraction force 30 N
Actuating force 35 N
Insertion depth min.52 mm
Cover lid Black
Electrical connection ratings
Thermal rated current Ith 4 A 70°C => 2A'>
Utilization category according to EN 60947-5-1
AC-15 4A 230V 70°C => 2A'>
DC-13 4A 24V 70°C => 2A'>
Solenoid operating voltage
AC/DC 24 V -15% ... +10%
Short circuit protection according to IEC 60269-1
(Fuse) 4A gG 70°C => 2A gG'>
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2,5 kV
Switching voltage
Min. at 10mA 12 V
Switching current
Min. at 24V 1 mA
Power consumption 10 W
Solenoid duty cycle 100 %
LED indicator Operating voltage corresponds to the solenoid voltage
Reliability values according to EN ISO 13849-1
Control of the guard locking
Category Depending on external control of guard locking
Performance Level Depending on external control of guard locking
PFHD Depending on external control of guard locking
Monitoring of guard locking and the safety guard position
B10D 3 x 106
In combination with Actuator BETAETIGER-Z-GNMechanical values and environment
Overtravel 16 mm
In combination with Actuator BETAETIGER-Z-GMechanical values and environment
Overtravel 4 mm