Manufacturer
Euchner
Country
Germany
Name
CET3-AR-CRA-AH-50F-SG-113965
Part number
113965
Description
CET3-AR-CRA-AH-50F-SG-113965 Non-contact safety switch CET-AR-..., M12, with escape release
Stock availability:
On request
If you are looking for Euchner CET3-AR-CRA-AH-50F-SG-113965 113965, communicate with FAMAGA, the world's the best distributor of industrialized equipment. Our company has functioned for more than ten years - these are ages of experience, which are represented in the quality of products and individual attention to each customer. We admire everyone, who joined with us - hence, our regular buyers accept the most beneficial purchase terms and discounts on the manufacturing equipment market. Nowadays, there are more than 4000 such clients, and we constantly arrange new agreements. More than 750 contracts are concluded per day, because FAMAGA supplies all over the world Germany, United Kingdom, Singapore, Liberia, Congo, Israel, Palestine, Uzbekistan, Papua New Guinea, Moldova, Thailand, Kyrgyzstan, Guyana, Zimbabwe, Turkmenistan, Burma, Niger, New Zealand, Mongolia, Ukraine, Lithuania, Chad, Tajikistan, Turkey, Burkina Faso, Kenya, Uruguay, Bosnia and Herzegovina, Armenia, India, Dominica, Uganda, Djibouti, Norway, Eswatini, Kazakhstan, Qatar, Ghana, Angola, Indonesia, Rwanda, Czech Republic, Equatorial Guinea, Namibia, Tunisia. A advanced logistics link and a partnership network help us to send our goods anywhere in the world quickly without damaging product quality.
A specific source of honor for FAMAGA is its employees, each of whom contributes to our work. We propose into our team only professionals, who already have experience in the direction of machine made streamlined equipment.
All products from FAMAGA are assured - we are responsible for the aftereffect of our work. Now, more than 10 million units of products have been provided, and this quantity is growing every day. We are proud that users choose FAMAGA again and again, and we are glad to make more progressive and technologically advanced industrial equipment so as keep on top of it.
To ask a question or make a request, phone us or send a message to the online chat on our site. You can also forward a list of the required equipment to the email of organization - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
CET3 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active. |
LED State | Status LED |
LED DIA | Diagnostic LED |
LED 1 rd | freely configurable |
LED 2 gn | illuminates when door is closed |
OUT | Monitoring output (semiconductor) |
OUT D | Door monitoring output (semiconductor) |
RST | Reset input |
J | Teach-in input |
Housing material | |
Slide | Stainless steel |
Safety switch housing | Die-cast aluminum |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
Z | ±4 mm |
Y | ±5 mm |
X | ±5 mm |
Ready delay | 10 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5 and 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Operating voltage DC | |
UB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
LED | 24 V DC -15% ... 10% |
Current consumption | |
IB | 80 mA |
ICM | 480 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (solenoid operating voltage UCM) | 0,5 ... 8 A |
External (operating voltage UB) | 0,25 ... 8 A |
Power consumption | |
Solenoid | max.12 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | 30V DC, 2A |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs OA/OB | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output OA / OB | 1 ... 200 mA |
Output voltage | |
High U(OA) / U(OB) | UB-1,5V ... UB V DC |
Low U(OA) / U(OB) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.400 ms |
Switch-on time | 400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT | 1 ... 50 mA |
Output voltage | |
OUT | 0,8xUB ... UB V DC |
Switching delay from state change | max.400 ms |
Monitoring output OUT D | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT D | 1 ... 50 mA |
Output voltage | |
OUT D | 0,8xUB ... UB V DC |
Switching delay from state change | max.700 ms |
Teach-in input | |
Input voltage | |
High | 15 ... 27,6 V DC |
Low | 0 ... 1 V DC |
Repeat accuracy R | 10 % |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Monitoring of guard locking and the safety guard position | |
Category | |
Head upward | 3 |
Head downward or horizontal | 4 |
Performance Level | PL e |
PFHD | |
Head downward or horizontal | 3.1 x 10-9 |
Head upward | 4.29 x 10-8 |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Mission time | 20 y |