We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CET3-AR-CRA-CH-50X-SG-C2290-110114
Part number
110114
Description
CET3-AR-CRA-CH-50X-SG-C2290-110114 MULTICODE Berührungsloser Sicherheitsschalter CET-AR-....M12 mit Kabelfrontentriegelung
Stock availability:
On request
If you are pursuing Euchner CET3-AR-CRA-CH-50X-SG-C2290-110114 110114, get in touch with FAMAGA, the world's main vendor of machine made equipment. Our company has functioned for more than ten years - these are years of experience, which are represented in the quality of products and private attention to each purchaser. We respect everyone, who joined with us - hence, our regular consumers procure the most flexible purchase conditions and discounts on the manufacturing equipment market. At present, there are more than 4500 such customers, and we constantly make new agreements. More than 750 purchases are terminated per day, because FAMAGA supplies all over the globe Germany, United Kingdom, Malawi, Uzbekistan, Canada, Guinea, Dominica, Ghana, Jordan, Colombia, Tunisia, Papua New Guinea, Afghanistan, Belgium, Chile, Botswana, Paraguay, Gambia, Cape Verde, Angola, Nicaragua, Saudi Arabia, Uruguay, Ecuador, Laos, Eswatini, Seychelles, Croatia, Czech Republic, Mali, South Korea, Turkmenistan, Kiribati, Antigua and Barbuda, Central African Republic, Hungary, North Korea, Argentina, Niger, United Arab Emirates, Lithuania, Cameroon, Tonga, Namibia, Algeria, Burkina Faso. A well-built logistics connection and a partnership network assist us to dispatch our goods anywhere in the earth quickly without disreputing product quality.
A special source of pride for FAMAGA is its team members, each of whom contributes to common cause. We request into our team only professionals, who already have experience in the range of machine made streamlined equipment.
All spare parts from FAMAGA are verified - we are responsible for the aftereffect of our work. Nowadays, more than 10 million units of products have been provided, and this quantity is ascending every day. We are glad that customers choose FAMAGA again and again, and we are happy to make more progressive and technologically advanced industrial equipment so as keep on top of it.
To consult or make a request, get in touch with us or write to the online chat on our site. You can also dispatch a list of the needful equipment to the email of organization - we will contact you ourselves with a made commercial proposal from FAMAGA.
CET3 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active. |
LED State | Status LED |
LED DIA | Diagnostic LED |
LED 1 rd | freely configurable |
LED 2 gn | illuminates when door is closed |
OUT | Monitoring output (semiconductor) |
OUT D | Door monitoring output |
RST | Reset input |
Housing material | |
Safety switch housing | Die-cast aluminum |
Slide | Stainless steel |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
X | ±5 mm |
Y | ±5 mm |
Z | ±4 mm |
Ready delay | 10 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5 and 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Operating voltage DC | |
LED | 24 V DC -15% ... 10% |
UB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IB | 80 mA |
ICM | 480 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (solenoid operating voltage UCM) | 0,5 ... 8 A |
External (operating voltage UB) | 0,25 ... 8 A |
Power consumption | |
Solenoid | max.12 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | 30V DC, 2A |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs OA/OB | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output OA / OB | 1 ... 200 mA |
Output voltage | |
High U(OA) / U(OB) | UB-1,5V ... UB V DC |
Low U(OA) / U(OB) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Risk time according to EN 60947-5-3 | |
Single device | max.400 ms |
Delay per device | 5 ms |
Switch-on time | 400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT | 1 ... 50 mA |
Output voltage | |
OUT | 0,8xUB ... UB V DC |
Switching delay from state change | max.400 ms |
Monitoring output OUT D | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT D | 1 ... 50 mA |
Output voltage | |
OUT D | 0,8xUB ... UB V DC |
Switching delay from state change | max.700 ms |
Repeat accuracy R | 10 % |
C number | |
C2290 | With wire front release (bowden) mounted |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Monitoring of guard locking and the safety guard position | |
Category | |
Head downward or horizontal | 4 |
Head upward | 3 |
Performance Level | PL e |
PFHD | |
Head downward or horizontal | 3.1 x 10-9 |
Head upward | 4.29 x 10-8 |
Mission time | 20 y |